SMX Pessral Modules

You are here:

SMX Pessral Modules include: SMX 10P, SMX 11P

i

SMX 10P

Free programmable compact-type safety control without Safe Motion (PESSRAL)

  • 14 safe digital inputs
  • 2 safe digital outputs
  • 1 safe relay output 
  • 2 clock / auxiliary output
  • Safety control suitable up to PL e (EN ISO 13849-1) / SIL3 (IEC 61508), use as PESSRAL acc. to DIN EN 81-20/50:2014
  • optional: safe/non-safe fieldbus interface
  • Extendable up to:
    • max. 42 safe digital inputs
    • max. 12 safe digital outputs
    • max. 20 safe digital I/O‘s
    • max. 11 safe relay outputs
    • max. 10 auxiliary outputs
  • Logic processing up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Free programmable small controller for up to 800 AWL instructions
  • Functionplan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Monitored relay outputs for safety relevant functions
  • Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Status monitoring by coded 7-segment-display and status LEDs
  • Multifunction buttons (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² Seriel USB-adapter or Ethernet-based fieldbus
  • Optional: expandable with communication module (SMX5x):
    • Standard and safe field bus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, DeviceNet, CANopen, CAN2.0, EtherCAT)
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchnage with distrubted I/O systems
  • CAN-Communication in connection with the SMX5x for diagnostics via backplane bus assembly on hat rail
  • The mechanical construction of the SMX10P (/5x*) is dependent on the respective forms of the base module

* Optional: expandable with communication modules:
  SMX51 CAN2.0 / SMX52 PROFIBUS / SMX53 PROFINET / SMX54 CANopen / SMX 55 EtherCAT

|

SMX 11P

Free programmable compact-type safety controller with Safe Motion (PESSRAL)

  • Integrated axis monitoring for 1 axis
  • 3 Encoder interface
  • 14 Safe digital inputs
  • 2 Safe digital outputs 
  • 1 Safe relay output 
  • 2 Clock / auxiliary output
  • Safety control suitable up to PL e (EN ISO 13849-1) / SIL3 (IEC 61508), use as PESSRAL acc. to DIN EN 81-20/50:2014
  • optional: safe/non-safe fieldbus interface
  • Extendable up to:
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/O‘s,
    • max. 9 safe relay outputs,
    • max. 10 auxiliary outputs,
    • max. 1 safe axis
  • Logic processing up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Movement monitoring of one axis up to Pl e EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Speed monitoring:
  • RPM-monitoring
  • Standstill monitoring
  • Sense of rotation monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Freely programmable compact-type control for up to 800 IL instructions
  • functionplan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Complete speed and position-based safety functions for drive monitoring in accordance with
    IEC 61800-5-2 are integrated in firmware:
    • Spatial functions for safe speed and are monitoring are possible Comprehensive
      diagnostics functions integrated
  • Umfangreiche Diagnosefunktionen integriert
  • Parameter management for expansion modules in base module
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction buttons (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² über USB serial adapter or Ethernet based field bus
  • Optional: expandable with communication module:
    • Standard and safe field bus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, DeviceNet, CANopen, CAN2.0, EtherCAT)
    •  Field bus protocols with the same hardware can be switched with SafePLC²
    •  Safe remote I/O communication for data exchnage with distrubted I/O systems
  • CAN-Communication in connection with the SMX5x for diagnostics via backplane bus assembly on hat rail
  • The mechanical construction of the SMX11P (/5x*) is dependent on the respective forms of the base module

* Optional: expandable with communication modules:
  SMX51 CAN2.0 / SMX52 PROFIBUS / SMX53 PROFINET / SMX54 CANopen / SMX 55 EtherCAT