Products:
eloProg base modules Standard

Product Overview
- 8 safety inputs and 2 solid-state safety output pairs (4 outputs) enable use as a stand-alone device
- 4 test outputs for sensor monitoring
- Diagnostics via 2 configurable control outputs and LEDs
- 2 EDM inputs for monitoring of downstream contactors or connection of a start push button
- Up to 14 expansion modules (up to 4 devices of any given module variant) can be connected
- Optional 350EPT T-connector (proprietary 5-way bus) for space-saving connection of the base module with expansion modules
- Optional 350EPU USB cable for transferring the configuration to the base module
- Optional 350EPS memory card for data storage and base module configuration without PC
The base module is a configurable safety control unit that can be used as a stand-alone device. Communication with expansion modules is through an internal 5-way bus.
The safety function previously configured on the PC can be directly installed via USB. The base module also features a memory card slot.
Download Datasheet
eloProg input/output module 485EPE_A

Product Overview
- 8 safety inputs and 2 safe, redundant transistor outputs
- 4 test outputs for sensor monitoring
- Diagnostics via 2 configurable control outputs and LEDs
- EDM inputs for monitoring of downstream contactors or connection of a start push button
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in theswitch cabinet
The input/output module expands the inputs and outputs, the test outputs and control inputs of the base module.
Download Datasheet
eloFlex 471EFR…

Product Overview
- Up to 4 safety functions can be implemented in one device
- The number of safety outputs (relays) can be set according to the individual requirement, making this a cost-effective solution.
- Increased functionality using less space in the switch cabinet.
- The units are tamper-proof as are pre-configured during ordering.
- Cost-effective and reliable by unique identification of configuration for maintenance, commissioning and service
- Can be perfectly adapted to your application through various configuration options, offering maximum flexibility
- Additional sensors can be connected via elobau interfaces for input expansion
Download Datasheet
eloProg input expansion 485EPE

Product Overview
- Up to 8 test outputs for sensor monitoring
- Diagnostics via LEDs
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in the switch cabinet
Depending on the module variant, the input modules can be expanded by an additional 8, 12 or 16 safety inputs.
Up to 4 additional expansion units of the same type (e.g. input module) can be connected to the base module. This allows a maximum number of 128 safety inputs to be achieved.
Download Datasheet
eloProg output expansion 485EPA

Product Overview
- Up to 4 safe, redundant transistor outputs
- Diagnostics via up to 4 configurable control outputs and LEDs
- Up to 4 EDM inputs for monitoring of downstream contactors or connection of a start push button
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in the switch cabinet
The output expansions extend the number of safe OSSD outputs in steps of two or four.
Up to 4 additional expansion units of the same type (e.g. input module) can be connected to the base module. This allows a maximum number of 16 safety outputs.
Download Datasheet
eloProg relay modules 485EPR

Product Overview
- Up to 4 safe, redundant relay outputs (NO contacts)
- Diagnostics via up to 4 configurable control outputs and LEDs
- Up to 4 EDM inputs for monitoring of downstream contactors or connection of a start push button
- EDM output for return to base or output module
- Depending on the variant, connection to the base module and other expansion modules with pre-assembled T-connector (proprietary 5-waybus) or wiring via connection terminals
The expansion modules with relay outputs have up to 4 force-guided NO relay contacts. They have been designed to handle 6A and 240V AC. In addition, up to 8 electronic control outputs are available for diagnostics.
Download Datasheet
eloProg rotational speed modules 485EPS

Product Overview
- Various modules for the connection of 1 or 2 HTL, TTL or sine/cosine encoders
- Additional inputs for up to 2 proximity sensors per module
- 4 switching thresholds can be configured per axis
- Rotational speed monitoring up to PLe
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in the switch cabinet
The speed modules monitor standstill, maximum speed, a defined speed range and the rotation direction. In addition, up to 4 switching thresholds can be configured per axis.
The various modules are compatible with encoders with HTL, TTL or sine/cosine signals.
Download Datasheet
eloProg signal output modules 485EPA00S

Product Overview
- Signal output module with 8/16 configurable control outputs for simple diagnosis
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in the switch cabinet
Download Datasheet
eloProg fieldbus modules

Product Overview
- All common fieldbus protocols are available
- Selectable station addresses via bus configurator
- Bus connection reduces wiring effort and expense
- Different transmission rates depending on selected fieldbus
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module simplifies wiring and saves space in the switch cabinet
Direct connection to the machine control/PLC through the fieldbus modules. The configuration takes place with own bus configurator.
Up to 1 fieldbus module can be connected to the base module via the T-connector at the back of the module. The status is displayed via LEDs on the front.
Download Datasheet
eloProg 485 EPT bus transfer modules

Product Overview
- Simple connection of the bus transfer modules with screw terminals
- Minimal wiring effort and expense thanks to bus connection
- Bus cable length up to 250 m
- Up to six module stations
- us transfer modules are not considered expansion modules (in regards to the max. number of connected modules)
- Pre-assembled T-connector (proprietary 5-way bus) for connection to the base module and other expansion modules simplifies wiring and saves space in the switch cabinet
Decentralised positioning of the eloProg I/O modules is achieved through the bus transfer modules.
The 485 EPT1 module is for use at the beginning and end of the connection; and type 485 EPT2 is for the middle.
This means up to six eloProg module stations with a maximum bus length of 250 m can be implemented. This makes it the perfect solution for large machinery and systems with a reduced wiring effort and expense.
Download Datasheet
eloProg memory card 350EPS

Product Overview
- Simple data transmission
- Without PC
With the memory card, configuration data can be transmitted without a PC to another base module.
Download Datasheet
eloProg T-connector

Product Overview
- 5-way high-speed bus
- Thanks to plug connections, no wiring necessary
The connector connects the individual modules in a space-saving way. A 5-way high-speed bus allows the modules to communicate. Additional wiring is therefore not necessary.
Download Datasheet
eloProg USB cable 350EPU

Product Overview
- 3 m cable
- For transferring the data between PC and 485EPB base module
Download Datasheet
eloFlex Mini 470EFR…

Product Overview
- Up to 2 safety functions can be implemented in one device
- The number of safety outputs (relays) can be set according to the individual requirement, making this a cost-effective solution
- Increased functionality using less space in the switch cabinet
- The units are tamper-proof as are pre-configured during ordering
- Cost-effective and reliable by unique identification of configuration for maintenance, commissioning and service
- Can be perfectly adapted to your application through various configuration options, offering maximum flexibility
- Additional sensors can be connected via elobau interfaces for input expansion
Download Datasheet
Safety relay 46212

Product Overview
- PLe/SIL3/Cat.4
- Supply voltage 24V AC and DC
- Connection for 4 sensors normally open/ normally closed
- Monitoring of connected contactors (EDM)
- Very compact design
- 1 relay safety output potential-free SIL3/PLe/Kat.4
- 1 control output changeover contact potential-free
- LEDs for status and error indication
The compact design of the 4621273E safety evaluation unit allows it to be used even in applications with limited space.
A potential-free safety output in SIL3/PLe up to 4A and a control output with change-over contacts up to 3A are available. A maximum of 4 sensors with normally open/ normally closed contacts can be connected. Input expansion units (interfaces) can’t be used. Due to the 24V AC and DC supply voltage, the unit can be used for a wide range of applications.
The 4621273E can be used as a pin-compatible replacement for
462121E1
462121E1U (Note: different operating time)
462121E101
462121E1U1 (Note: different operating time)
462121E104
462124E1 (Note: different operating voltage AC 230 V)
462124E1U (Note: different operating voltage AC 230 V and different operating time)
462121H1
462121H1U (Note: different operating time)
462121H5
462121H5U (Note: different operating time)
Circuit examples are available on request from elobau.
Download Datasheet
Interfaces for input expansion

Product Overview
- Up to PLd in accordance with EN ISO 13849-1 and SIL2 in accordance with IEC 61508
- Screwless terminals for easy installation
- Status diagnostics via control outputs and LEDs
- Number of sensors can be increased to 4 per sensor input
- By cascading, it is possible to connect up to 64 sensors to one safety control unit*
* To achieve the maximum performance level, it is necessary to integrate the control outputs in the evaluation (start interlock in the event of a fault). If interfaces are cascaded, this can result in a reduction of the maximum performance level PL. Connection examples are available from elobau.
With the interface modules, the number of safety inputs and outputs can be increased.
A large number of safety functions can be monitored by cascading multiple modules.