Light curtain controllers

You are here:

Monitor light barriers and light grids

If persons or objects approach a dangerous area, the DOLD light barrier switching devices deactivate the dangerous movement via contactless safety devices (AOPD) and ensure a safe condition. The light barrier switching devices are used to protect persons that regularly during the handling process must reach into machines and systems that are also a source of danger. A typical application is the conveying and removal of work pieces to presses. A benefit of this solution is higher productivity through longer cycle times as well as by refraining from mechanical safety devices – without having to reduce the safety level.

Light curtain controller LG 5925/900

Product description

  • Protection of people and machines
  • Light curtain controller for light curtains with selftesting (Type 4) according to IEC/EN 61 496-1
  • Usage in furnace application in continuous operation acc. to EN 50156-1

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • According to EN 50156-2 for furnaces
  • For light curtains with symmetric or asymmetric outputs adjustment with switch S1
  • Output: max. 4 NO contacts, see contacts
  • Single and 2-channel operation
  • Line fault detection on On-button
  • Manual restart or automatic restart, switch S2
  • LED indicator for channel 1, 2 and supply voltage
  • Removable terminal strips
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
  • As option with pluggable terminal blocks for easy exchange of devices
    – With screw terminals
    – Or with cage clamp terminals
  • Width 22.5 mm

Safety module, light curtain UG 6980/800

Product description

The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 1 out of 6 safety functions on rotary switches – ready. This reduces divers types of safety modules in stock and simplifies your disposition.

 

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: max. 4 NO instantaneous semiconductor monitoring output
  • LED indicator for operation, delay contects and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • Width: 22.5 mm

Light curtain controller with selectable operating modes BH 5902

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL 3) to IEC/EN 61508
  • To connect max.:
    – 3 light curtains 2-channel or
    – 2 light curtains 2-channel and 2 muting sensors 1-channel or
    – 1 light curtain 2-channel and 4 muting sensors 1-channel or
    – 2 light curtains 2-channel and key switch for stepping operation
    – Additionally: Start button and machine contact with line fault detection
  • Broken wire detection on light curtain input
  • Outputs:
    – 3 NO or 2 NO and 1 NC
    – 2 Semiconductor outputs, protected against short circuit and overload
  • Multifunction device, different functions selectable by rotational switches:
    – Protective operation e.g. light curtains
    – Protective operation with muting, e.g. conveyors
    * Signal sequence of muting sensors can be selected
    * Override function via start button
    – Stepping operation e.g. on presses
    * Optionally with key switch
    * 1, 2 or 3 steps possible
    * Setting of number of step possible via selector switch
  • Suitable to connect light curtains of type 4 or selftesting light curtains type 2 according to IEC/EN 61 496-1, crossfault monitoring in the light curtain
  • With under- and overvoltage detection and indication
  • Reaction time: max. 30 ms
  • LED indication for RUN and Channel 1,2
  • Width 45 mm

For all your automation project needs: