Multifunction relays

You are here:

Universally usable – maximum function in minimum width

Multifunctional relays are universally usable thanks to the selection of the corresponding function. They also belong to the group of time relays with which you can cost-effectively realised specific time functions. A multifunctional relay can be used as a flasher relay, clock, impulse former, start-up and/or shut-down relay as well as contact and recurrence delay. 

Multifunction relay IK 7817N/200

Features

  • According to IEC/EN 61812-1
  • 8 functions settable via rotational switch:
    – Delay on energisation (AV)
    – Fleeting on make (EW)
    – Delay pulse (IE)
    – Flasher, start with pulse (BI)
    – Delay on de-energisation (RV)
    – Pulse forming function (IF)
    – Fleeting on break (AW)
    – Delay on energisation and de-energisation (AV / RV)
  • 8 time ranges from 0.02 s … 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • With time interruption / time adding input
  • Adjustment aid for quick setting of long time values
  • Suitable for 2-wire proximity sensor control
  • 1 changeover contact
  • LED indicators for operation, contact position and time delay
  • Devices available in 2 enclosure versions:
    IK 7817N: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 7817N: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • DIN rail or screw mounting
  • 17.5 mm width
  • IK/SK 7817N/500: as IK/SK 7817N/200 but with
  • 2 additional functions:
    – Cyclic timer, start with break (TP)
    – Fleeting on make and break (EW / AW)
  • second time setting t2 for functions
    – Cyclic timer, start with pulse (TI) or break (TP), based on the separate setting of pulse and break time the flasher function can be used as cyclic timer.
    – Fleeting on make and break (EW/AW)
    – Delay on energisation and de-energisation (AV / RV)
    – Delay pulse (IE): setting of pulse length
  • Connection facility for external potentiometer 10 kΩ

Multifunction relay RK 7817

Advantages

  • Timers in compact design enclosures for consumer units
    – Multifunction relay RK 7817 with 8 functions and adjustment aid for quick setting of long times

Features

  • According to IEC/EN 61812-1
  • 8 time ranges adjustable from 0.02 s to 300 h via rotational switches
  • Dual-voltage-version AC 230 V + AC/DC 24 V or AC 110 … 127 V + AC/DC 24 V
  • Signle-voltage-version AC/DC 24 V or DC 12 V
  • 1 changeover contact
  • As option units with second changeover contact (only for voltage AC 230 V + AC/DC 24 )
    – on delayed
    – as instantaneous contact
  • 8 functions via rotational switches adjustable:
    – delay on energisation (AV)
    – fleeting on make (EW)
    – delayed pulse (IE)
    – flasher, start with puls (BI)
    – delay on de-energisation (RV)
    – pulse forming function (IF)
    – fleeting on break (AW)
    – delay on energisation and de-energisation (AV / RV)
  • With time interruption / time adding
  • LED indicators for operation, contact position and time delay
  • Width: 17.5 mm

Multifunction relay SK 7817N/200

Features

  • According to IEC/EN 61812-1
  • 8 functions settable via rotational switch:
    – Delay on energisation (AV)
    – Fleeting on make (EW)
    – Delay pulse (IE)
    – Flasher, start with pulse (BI)
    – Delay on de-energisation (RV)
    – Pulse forming function (IF)
    – Fleeting on break (AW)
    – Delay on energisation and de-energisation (AV / RV)
  • 8 time ranges from 0.02 s … 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • With time interruption / time adding input
  • Adjustment aid for quick setting of long time values
  • Suitable for 2-wire proximity sensor control
  • 1 changeover contact
  • LED indicators for operation, contact position and time delay
  • Devices available in 2 enclosure versions:
    IK 7817N: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 7817N: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • DIN rail or screw mounting
  • 17.5 mm width
  • IK/SK 7817N/500: as IK/SK 7817N/200 but with
    2 additional functions:
    – Cyclic timer, start with break (TP)
    – Fleeting on make and break (EW / AW)
  • second time setting t2 for functions
    – Cyclic timer, start with pulse (TI) or break (TP), based on the separate setting of pulse and break time the flasher function can be used as cyclic timer.
    – Fleeting on make and break (EW/AW)
    – Delay on energisation and de-energisation (AV / RV)
    – Delay pulse (IE): setting of pulse length
  • Connection facility for external potentiometer 10 kΩ

Multifunction relay BC 7935N

Features

  • According to IEC/EN 61812-1
  • 8 functions selectable by rotational switch:
    AV – Operate delay
    EW – Fleeting on make
    IE – Delayed pulse function
    BI – Flashing function symmetrical, start with pulse
    RV – Release delay
    IF – Pulse forming
    AW – Fleeting on break
    AV/RV – Operate / release delay
  • With 10 time ranges up to 300 h selectable by rotational switch
  • Time addition via control input B1 for the functions AV, EW, IE, BI
  • Operating voltage AC/DC 24 … 240 V, DC 12 V
  • 1 changeover contact
  • LED indicators for voltage supply and contact position, flashing function during elapse of time
  • Width 22.5 mm

Multifunction relay, digital MK 7830N

Advantages

  • Always the correct timer on stock
  • Space saving in industrial cabinets because 2 multifunction relays in one compact enclosure
  • Precise time delay by digital setting

Features

  • According to IEC/EN 61812-1
  • Digital adjustable multifunction timer
  • Functions can be adjusted separately for each output relay
    – Off (OFF)
    – Instantaneous contact (ON)
    – On-delay (AV)
    – Fleeting on make (EW)
    – Delayed pulse with adjustable pulse length (IE)
    – Cyclic timer, start with impulse (TI)
    – Cyclic timer, start with break (TP)
    – Off-delay (RV)
    – Pulse forming function (IF)
    – Fleeting on break (AW)
    – Fleeting on make and break (EW / AW)
    – On and off delay (AV / RV)
    – Relay 1 = Relay 2, both switch simultaneously
  • Dual voltage model AC 230 V + AC/DC 24 V
  • 2 changeover contacts
  • 2 times separately adjustable from 0.02s to 9999h
  • LED-indicator
  • As option with pluggable terminal blocks for easy exchange of devices
    – With screw terminals
    – Or with cage clamp terminals
  • Width: 22.5 mm

Multifunction relay MK 7850N

Advantages

  • Up to 10 functions in one unit
  • Simplified storage
  • Increased flexibility
  • Quick setting of long time values

Features

  • According to IEC/EN 61812-1
  • 8 functions settable via rotational switch:
    – Delay on energisation (AV)
    – Fleeting on make (EW)
    – Delayed pulse (IE)
    – Flasher, start with pulse (BI)
    – Delay on de-energisation (RV)
    – Pulse forming function (IF)
    – Fleeting on break (AW)
    – Delay on energisation and de-energisation (AV / RV)
  • 8 time ranges from 0.02 s to 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • With time interruption / time adding input for all functions
  • Suitable for 2-wire proximity sensor control
  • 2 changeover contacts, one programmable as instantaneous contact
  • LED indicators for operation, contact position and time delay
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
  • as option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • 22.5 mm width

  • MK 7850N/500: as MK 7850N/200 but with
  • 2 additional functions:
    – Cyclic timer, start with break (TP)
    – Fleeting on make and break (EW / AW)
  • second time setting t2 for functions
    – Cyclic timer, start with pulse (TI) or break (TP), based on the separate setting of pulse and break time the flasher function can be used as cyclic timer
    – Fleeting on make and break (EW/AW)
    – Delay on energisation and de-energisation (AV / RV)
    – Delay pulse (IE) and setting of pulse length
  • Connection facility for 2 external potentiometers

Multifunction relay EO 9920/200

Advantages

  • Flush mounting- or DIN rail mounting

Features

  • According to IEC/EN 61812-1
  • 10 time ranges from 0.05 s … 30 h
  • Programmable on front side for
    – On delay (E)
    – Release delay (A)
    – Fleeting on make (WE)
    – Fleeting on break (WA)
  • 2 changeover contacts
  • Voltage range AC/DC 24 … 240 V

Multifunction relay SN 7920

Advantages

  • Higher flexibility (8 function in one unit)
  • To switch high DC-loads with mechanical forcibly guided contacts according to IEC 61810-3

Features

  • According to IEC/EN 61 812-1, DIN EN 50155
  • 8 functions settable via rotational switch:
    – Delay on energisation (AV)
    – Fleeting on make (EW)
    – Delay pulse (IE)
    – Flasher, start with pulse (BI)
    – Delay on de-energisation (RV)
    – Pulse forming function (IF)
    – Fleeting on break (AW)
    – Delay on energisation and de-energisation (AV / RV)
  • 8 time ranges from 0.05 s … 300 h selectable via rotational switches
  • Voltage range AC/DC 24 … 230 V
  • High DC switching capacity
  • With time interruption / time adding input
  • Adjustment aid for quick setting of long time values
  • Contacts:
    – 1 NC + 2 NO delayed
    – 1 NC + 2 NO delayed or instantaneous
  • LED indicators for operation, contact position and time delay
  • DIN rail or screw mounting
  • 52.5 mm width

For all your automation project needs:

Get in touch with us today!