Bistable relays – Energy-efficient and reliable switching
Bistable relays can be used to switch applications in a reliable and energy-saving manner. They retain their switched position if supply voltage fails, preventing loss of information on the current switching status.
Printed circuit board relay, bistable OB 5693

Product Overview
Features
- According to DIN EN 61810-1, IEC/EN 60669-1
- Switching reliability according to IEC/EN 60669-2-2
- Safe separation according to IEC/EN 61140, IEC/EN 60335
- OB 5693: horizontal model
OB 5694: vertical model - Bistable, mechanical latching of contact
- For impulse operation, at failure operation 100 % ED possible
- Same pulse (energy and direction) for both switching positions
- AC and DC – model
- Patent on function principle
- On request wash proof
Datasheet Download
Printed circuit board relay, bistable OB 5694

Product Overview
Features
- According to DIN EN 61810-1, IEC/EN 60669-1
- Switching reliability according to IEC/EN 60669-2-2
- Safe separation according to IEC/EN 61140, IEC/EN 60335
- OB 5693: horizontal model
OB 5694: vertical model - Bistable, mechanical latching of contact
- For impulse operation, at failure operation 100 % ED possible
- Same pulse (energy and direction) for both switching positions
- AC and DC – model
- Patent on function principle
- On request wash proof
Datasheet Download
Bistable relay OB 5623

Product Overview
Features
- According to DIN EN 61810-1, DIN EN 61810-3 (Type A)
- With forcibly guided contacts
- Energy efficient, low energy consumption, because of impulse control, no holding consumption
- Bistable, mechanical latching of contact position
- Safe separation between all current circuits
- Both coils non-polarised, neutral
- Defined position when both coils are operated simultaneously
- Impulse operation, duty cycle possible (under fault condition)
- Wide temperature range
- As option with manual operation (mechanical indication)
- Washproof (only without manual operation)
- Height 15.8 mm