Current relays for monitoring over- and undercurrent
Current relays are electronic measuring relays for monitoring alternating and direct currents for exceeding or falling below a set threshold value. Depending on the version, one or more loads can be monitored with one device. Special applications where measuring relays can be used for current monitoring are stone and woodworking machines and wherever it is necessary to monitor over- or undercurrent.
Current Monitor IK 8839

Product Overview
Features
- According to IEC/EN 60255-1
- Measuring range 0.175 … 1 A
- Fixed switching point setting
- High maximum load
- 1 changeover contact
- LED indication for operation and output status
- Width 17.5 mm
Datasheet Download
Overcurrent Relay IK 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from AC 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- As option energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay IK 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Overcurrent Relay IK 9272

Product Overview
Advantages
- Adjustable switching delay
- Closed circuit operation (output relay not activated in case of error)
- Optionally open circuit operation (output relay activated in case of error)
- Optionally manual reset, reset button on the front
Features
- According to IEC/EN 60255
- Single phase
- 1 changeover contact
- Measuring ranges from 0.05 … 10 A
- Fixed hysteresis approx. 4 %
- Hysteresis function (auto reset)
- LED indication for auxiliary voltage and contact position
- Devices available in 2 enclosure versions:
IK 9272: Depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
SK 9272: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct - Width 17.5 mm
Datasheet Download
Undercurrent Relay IK 9273

Product Overview
Features
- According to IEC/EN 60 255
- Single phase
- Measuring ranges from 0.05 … 10 A
- Setting value adjustable from 0.1 … 1 IN
- Fixed hysteresis approx. 4 %
- Settable switching delay
- Closed circuit operation
- Optionally open circuit operation
- Automatic reset
- Optionally manual reset, reset button on the front
- LED indication for auxiliary voltage and contact position
- 1 changeover contact
- Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct - Width 17.5 mm
Datasheet Download
Overcurrent Relay SK 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from AC 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- As option energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay SK 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Overcurrent Relay SK 9272

Product Overview
Advantages
- Adjustable switching delay
- Closed circuit operation (output relay not activated in case of error)
- Optionally open circuit operation (output relay activated in case of error)
- Optionally manual reset, reset button on the front
Features
- According to IEC/EN 60255
- Single phase
- 1 changeover contact
- Measuring ranges from 0.05 … 10 A
- Fixed hysteresis approx. 4 %
- Hysteresis function (auto reset)
- LED indication for auxiliary voltage and contact position
- Devices available in 2 enclosure versions:
IK 9272: Depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
SK 9272: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct - Width 17.5 mm
Datasheet Download
Undercurrent Relay SK 9273

Product Overview
Features
- According to IEC/EN 60 255
- Single phase
- Measuring ranges from 0.05 … 10 A
- Setting value adjustable from 0.1 … 1 IN
- Fixed hysteresis approx. 4 %
- Settable switching delay
- Closed circuit operation
- Optionally open circuit operation
- Automatic reset
- Optionally manual reset, reset button on the front
- LED indication for auxiliary voltage and contact position
- 1 changeover contact
- Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct - Width 17.5 mm
Datasheet Download
Current Relay MK 9053N

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
Features
- According to IEC/EN 60255-1, IEC/EN 60947-1
- To: Monitor DC and AC
- Measuring ranges from 2 mA up to 10 A
- High overload possible
- Input frequency up to 5 kHz
- Galvanic separation between auxiliary circuit – measuring ciruit
- With start-up delay
- With time delay, up to max. 100 sec
- As option with remote potentiometer
- As option with manual reset
- Option with fixed settings possible
- LED indicators for operation and contact position
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals
– Or with cage clamp terminals - Width: 22.5 mm
Datasheet Download
Current relay MK 9063N

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
- Min-, Max. value or window monitoring
- Measuring ranges up to AC/DC 10 A
- Simple configuration and fault diagnostic
- Auxiliary voltage ranges DC 24 V, AC/DC 24 … 230 V or AC/DC 110 … 400 V
Features
- According to IEC/EN 60255-1
- AC/DC current measuring (single-phase)
- Start up delay, on delay
- Manual reset
- LCD for indication of the measuring values
- Relay output
MK 9063N: 1 changeover contact
MH 9063: 2 x 1 changeover contacts - Relay function selectable (energized/de-energized on trip)
- As option with plugable terminal blocks for easy exchange of devices
– with screw terminals
– or with cage clamp terminals - Width MK 9063N: 22.5 mm
- Width MH 9063: 45.0 mm
Datasheet Download
Current relay ML 9701

Product Overview
Advantages
- Purely electromechanical design
- High insensitivity to interference in the radio frequency range and high voltage peaks
- Easy device adjustment
- Can be used for under- or overcurrent detection
Features
- According IEC/EN 60255-1
- Single-phase
- Measuring ranges from 0,5 to 12 A
- Settable response value (Measuring value)
- Without auxiliary voltage
- Width 22.5 mm
Datasheet Download
Overcurrent Relay IL 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from AC 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- As option energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay IL 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay IL 9277

Product Overview
Features
- According to IEC/EN 60 25-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from AC 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Current Relay RL 9853

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- High repeat accuracy
- Wide measuring voltage range
- Easy setting
Features
- According to IEC/EN 60255-1
- For monitoring of current in DC and AC systems
- Detection of over- or undercurrent in AC- or DC mains
- Galvanic separation between auxiliary circuit – measuring ciruit
- Output: 1 changeover contact
- De-Energized on trip
- Adjustable switching current
- Adjustable hysteresis for reset
- Adjustable switching delay
- Fast fault detection
- Width: 35 mm
Datasheet Download
Overcurrent Relay SL 5201/20007CT

Product Overview
Features
- According to IEC/EN 60 255-1
- 2 independent relays in once enclosure
- 2 measuring ranges from 0.5 to 5 A
- Adjustable response values
- Fixed hysteresis
- Adjustable switching delay
- Closed circuit operation
- LED indicators
- With auyiliary voltage
- Galvanic separation between auxiliary circuit and measuring circuit
- 2 models available:
IL 5201: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880
SL 5201: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts - Width: 35 mm
Datasheet Download
Overcurrent Relay SL 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Overcurrent Relay SL 9270CT

Product Overview
Features
- According to IEC/EN 60 255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- de-energized on trip
- energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay SL 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Undercurrent Relay SL 9271CT

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay SL 9277

Product Overview
Features
- According to IEC/EN 60 255-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay SL 9277CT

Product Overview
Features
- According to IEC/EN 60 255-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Undercurrent Relay AI 837

Product Overview
Features
- According to nach IEC/EN 60 255-1
- Single-phase
- Without auxiliary supply
- Measuring ranges from 0.5 to 16 A
- Settable response value
- 1 changeover contact
- Width 45 mm
Datasheet Download
Overcurrent Relay AI 838

Product Overview
Features
- According to nach IEC/EN 60 255-1
- Single-phase
- Without auxiliary supply
- Measuring ranges from 0.5 to 16 A
- Settable response value
- 1 changeover contact
- Width 45 mm
Datasheet Download
Line breakage relay AI 940

Product Overview
Advantages
- Ohne separate Hilfsspannung
- Für Dauerströme bis 16 A
Features
- Nach IEC/EN 60255-1
- 3-phasig
- Aderbrucherkennung bei Strömen < 0,5 A
- 1 Wechsler
- 45 mm Baubreite
Datasheet Download
Current Relay BA 9053

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
Features
- According to IEC/EN 60255-1, IEC/EN 60947-1
- To: Monitor DC and AC
- Measuring ranges from 2 mA to 25 A
- Optionally with 3 measuring ranges 0.1 up to 25 A
- High overload possible
- Input frequency up to 5 kHz
- Galvanic separation between auxiliary circuit – measuring ciruit
- Auxiliary supply AC and AC/DC
- Optionally with start-up delay
- With time delay, up to max. 100 sec
- Optionally with safe separation to IEC/EN 61140 (on request)
- As option with manual reset
- Option with fixed settings possible
- LED indicators for operation and contact position
- Width: 45 mm
Datasheet Download
Current Relay BA 9053/041

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
Features
- According to IEC/EN 60255-1, IEC/EN 60947-1
- To monitor AC
- Measuring range from 1 … 10 A (others on request)
- High overload possible
- Galvanic separation between auxiliary circuit – measuring ciruit
- Auxiliary supply AC/DC
- With time delay, up to max. 100 sec
- LED indicators for operation and contact position
- Width 45 mm
Datasheet Download
Current relay MH 9063

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
- Min-, Max. value or window monitoring
- Measuring ranges up to AC/DC 10 A
- Simple configuration and fault diagnostic
- Auxiliary voltage ranges DC 24 V, AC/DC 24 … 230 V or AC/DC 110 … 400 V
Features
- According to IEC/EN 60255-1
- AC/DC current measuring (single-phase)
- Start up delay, on delay
- Manual reset
- LCD for indication of the measuring values
- Relay output
MK 9063N: 1 changeover contact
MH 9063: 2 x 1 changeover contacts - Relay function selectable (energized/de-energized on trip)
- As option with plugable terminal blocks for easy exchange of devices
– with screw terminals
– or with cage clamp terminals - Width MK 9063N: 22.5 mm
- Width MH 9063: 45.0 mm
Datasheet Download
Current measuring transducer MH 9353

Product Overview
Advantages
- Measuring relay and transducer in one unit
- Simple setting
- Cost saving
- Reduced wiring
Features
- According to IEC/EN 60255-1
- Galvanic separate analogue signals, optionally with
– 0 … 20 mA and 0 … 10 V or
– 4 … 20 mA and 2 … 10 V - Adjustable response value
- Fixed hysteresis
- LED indication for auxiliary voltage and contact position
- With auxiliary voltage
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals
– Or with cage clamp terminals - Width: 45 mm
Datasheet Download
Overcurrent Relay IP 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from AC 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- As option energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay IP 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay IP 9277

Product Overview
Features
- According to IEC/EN 60 25-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from AC 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Current Asymmetry Relay IP 9278

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Auxiliary supply and measuring input galvanic separated
- With integrated current transformer
- As option with external remote reset
Features
- According to IEC/EN 60255-1
- IP 9278, SP 9278: 3-phase
- Measuring range
IP 9278, SP 9278: Up to 15 A
SP 9278CT: Up to 100 A - 2 changeover contacts
- Adjustable asymmetry
- Settable time delay
- Open circuit operation
- LED indicators
- With auxiliary voltage
- Width 70 mm
Datasheet Download
Overcurrent Relay SP 9270

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Overcurrent Relay SP 9270CT

Product Overview
Features
- According to IEC/EN 60 255-1
- IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase - Measuring ranges from 0.1 … 100 A
- Settable response value
- Fixed hysteresis
- Settable time delay
- de-energized on trip
- energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Datasheet Download
Undercurrent Relay SP 9271

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Undercurrent Relay SP 9271CT

Product Overview
Features
- According to IEC/EN 60255-1
- IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: Single phase - Measuring ranges from AC 0.1 … 100 A
- IK 9271, SK 9271:
With 4 ranges settable by rotational switch, 1 changeover contact - IL 9271, SL 9271:
With 5 ranges settable by rotational switch, 1 changeover contact
With 4 ranges programmable by bridges, 2 changeover contacts - IP 9271, SP 9271: with 1 range, 2 changeover contacts
- Settable response value
- Fixed hysteresis
- Settable time delay
- De-energized on trip
- Optionally energized on trip
- LED indicators
- With auxiliary voltage
- Auxiliary supply and measuring input galvanic separated
- Devices available in 2 enclosure versions:
– I-model, e.g. IK _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SK _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay SP 9277

Product Overview
Features
- According to IEC/EN 60 25-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Over- and Undercurrent Relay SP 9277CT

Product Overview
Features
- According to IEC/EN 60 255-1
- IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase - Detects over- and undercurrent
- Measuring ranges from 0.1 … 15 A
- With built in current transformer for 0.5 … 100 A
- IL 9277, SL 9277 with 4 programmable ranges
- Settable 0.1 … 1 IN
- Separate setting for over- and undercurrent
- Fixed hysteresis approx. 4 %
- Settable time delay
- IP 9277, SP 9277 with separate settable time delay for over- and undercurrent
- De-energized on trip
- LED indicators for over-, under- and normal current
- Auxiliary supply and measuring input galvanic separated
- IL 9277, SL 9277 with one output relay for over- and undercurrent
- IP 9277, SP 9277 with separate output relays for over- and undercurrent
- Optionally energized on trip
- Devices available in 2 enclosure versions:
– I-model, e.g. IL _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
– S-model, e.g. SL _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct - DIN rail or screw mounting
- Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Datasheet Download
Current Asymmetry Relay SP 9278CT

Product Overview
Advantages
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Auxiliary supply and measuring input galvanic separated
- With integrated current transformer
- As option with external remote reset
Features
- According to IEC/EN 60255-1
- IP 9278, SP 9278: 3-phase
- Measuring range
IP 9278, SP 9278: Up to 15 A
SP 9278CT: Up to 100 A - 2 changeover contacts
- Adjustable asymmetry
- Settable time delay
- Open circuit operation
- LED indicators
- With auxiliary voltage
- Width 70 mm