Specific shut-down of drives
Delay modules from DOLD allow the specific shut-down of the drives which reduces the risk of injury. A typical area of use are high-speed tools that continue to move after shut-down. Productivity is not affected as the machine can be immediately started again. The emergency stop of the dangerous movement can be accelerated through a specific shut-down in accordance with stop category 1 by allowing motor braking functions to be applied during the switch-off delay and/or the speed of the drive can be regulated.

Product Overview
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Variants /_ _2 and /_ _ 3 can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Adjustable time delay
- Long time stability by digital timing circuit
- With auxiliary voltage
- 1 timing circuit
- BH 7925 in dual voltage version
- BH 7925 optionally for AC 230 V
- Output: 1 NC contact, 1 NO contact, forcibly guided or 1 NC contact, 3 NO contacts, forcibly guided
- Indication of state of operation
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Optionally with 2 timing circuits
- Optionally fixed time delay
- Optionally without auxiliary voltage on BH 7925
- Optionally for switching small loads
- BG 7925: width 22.5 mm
BH 7925: width 45 mm
Datasheet Download
Delay module, release delayed BG 7926

Product Overview
Advantages
- Easy to realise safe timing circuits
- 5 forcibly guided output contacts at only 22.5 mm width
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Redundant and forcibly guided contacts
- 1 timing circuit
- Fixed time delay 1, 2 or 3 sec
- Without auxiliary supply
- Output: 5 NO contacts or 4 NO contacts / 1 NC contact, 1 NC contact for feed back circuit
- Indicator LED for operation
- Removable terminal strips
- Wiring diameter: Also 2 x 1.5 mm2 stranded ferruled with sleeve DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3
- Width 22.5 mm
Datasheet Download
Delay module, on delayed LG 7927

Product Overview
Advantages
- Easy to realise safe timing circuits
- 4 forcibly guided output contacts at only 22.5 mm width
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Adjustable time delay
- As option fixed time delay
- High long life stability due to digital time base
- Adjustable with or without cross fault detection
- Output: 3 NO contacts + 1 NC contact + 1 forcibly guided
- feedback contact or 4 NO contacts + 1 forcibly guided feedback contact
- LED indicator for channel 1, 2 and operation voltage
- Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
- As option with pluggable terminal blocks for easy exchange of devices
– with screw terminals
– or with cage clamp terminals - Width 22.5 mm
Datasheet Download
Delay module, release delayed LG 7928

Product Overview
Advantages
- Easy to realise safe timing circuits
- 4 forcibly guided output contacts at only 22.5 mm width
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Adjustable time delay
- As option fixed time delay
- High long life stability due to digital time base
- Adjustable with or without cross fault detection
- Output: 3 NO contacts + 1 NC contact + 1 forcibly guided feedback contact or 4 NO contacts + 1 forcibly guided feedback contact
- LED indicator for channel 1, 2 and operation voltage
- Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals
– Or with cage clamp terminals - Width 22.5 mm
Datasheet Download
Delay module, release delayed IL 7824

Product Overview
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL c and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - BA 7924.21/002 and BA 7924.21/003 can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Release delay
- Without auxiliary voltage
- Output: 1 NC, 1 NO contacts, forcibly guided
- Operating state display
- Optionally with adjustable or fixed time delay up to 30 s
- Optionally with redundant timing circuit
- Optionally with 1 or 2 separate timing circuits
- Optionally also in housing for distribution board
- Width 45 mm, 35 mm or 52.5 mm
Datasheet Download
Delay module, Release Delay BA 7924

Product Overview
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL c and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - BA 7924.21/002 and BA 7924.21/003 can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Release delay
- Without auxiliary voltage
- Output: 1 NC, 1 NO contacts, forcibly guided
- Operating state display
- Optionally with adjustable or fixed time delay up to 30 s
- Optionally with redundant timing circuit
- Optionally with 1 or 2 separate timing circuits
- Optionally also in housing for distribution board
- Width 45 mm, 35 mm or 52.5 mm
Datasheet Download
Delay module, release delayed BH 7925

Product Overview
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Variants /_ _2 and /_ _ 3 can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Adjustable time delay
- Long time stability by digital timing circuit
- With auxiliary voltage
- 1 timing circuit
- BH 7925 in dual voltage version
- BH 7925 optionally for AC 230 V
- Output: 1 NC contact, 1 NO contact, forcibly guided or 1 NC contact, 3 NO contacts, forcibly guided
- Indication of state of operation
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Optionally with 2 timing circuits
- Optionally fixed time delay
- Optionally without auxiliary voltage on BH 7925
- Optionally for switching small loads
- BG 7925: width 22.5 mm
BH 7925: width 45 mm
Datasheet Download
Delay module, release delayed IN 7824

Product Overview
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL c and category 2 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - BA 7924.21/002 and BA 7924.21/003 can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
– Up to PL d and category 3 according to EN ISO 13849-1
– Up to SIL 2 according to EN 61508 and EN 61511 - Release delay
- Without auxiliary voltage
- Output: 1 NC, 1 NO contacts, forcibly guided
- Operating state display
- Optionally with adjustable or fixed time delay up to 30 s
- Optionally with redundant timing circuit
- Optionally with 1 or 2 separate timing circuits
- Optionally also in housing for distribution board
- Width 45 mm, 35 mm or 52.5 mm