Realisation of safety-oriented switching
Coupling modules from Dold are constructed with forcibly guided contacts a per IEC 61810-3. The forcibly guided opener allows the monitoring of the closing contacts. As a ling between logic and load, they are used for the switching of safety-oriented functions. Dold coupling modules are also used in the set up of self-monitoring safety switches. They are also the devices of choice for the adjustment of the control and power level as well as for the switching of safety-oriented functions.

Product Overview
Advantages
- Simple contact extension and re-inforcement also of safety modules
- Cost and space saving alternative compared to contactors
- Simple contact monitoring via forcibly guided NC contact
- Large wire cross section 0.5 – 2.5 mm² (12-24 AWG) reduces thermal load on wires
Features
- According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1
- With forcibly guided contacts according to IEC 61810-3
- Models with soldered in or plug-in PCB safety relay consisting of:
– plug in socket HC 3096N and safety relay OA 5611
– plug in socket HL 3096N and safety relay OA 5612 - With polarity protected diode
- Optionally with free-wheeling diode across A1+ and A2
- Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
- For DIN rail mounting according IEC/EN 60715
- HC 3096N: width 18 mm
HL 3096N: width 36 mm
Datasheet Download
Interface module LG 3096

Product Overview
Advantages
- Max. 6 contacts
- As option goldplated contacts to switch low loads
Features
- With forcibly guided contacts according to IEC 61810-3
- Wire connection: Also 2 x 1.5 mm2 stranded ferruled, or
- 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
- As option with pluggable terminal blocks for easy exchange of devices
– with screw terminals
– or with cage clamp terminals - Width 22.5 mm
Datasheet Download
Interface module MK 3096N

Product Overview
Advantages
- Max. 6 contacts
- As option goldplated contacts to switch low loads
Features
- With forcibly guided contacts according to IEC 61810-3
- Wire connection: Also 2 x 1.5 mm2 stranded ferruled, or
- 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
- As option with pluggable terminal blocks for easy exchange of devices
– with screw terminals
– or with cage clamp terminals - Width 22.5 mm
Datasheet Download
Interface module UG 3088

Product Overview
Advantages
- According to IEC/EN 60947-5-1
- Economic and space safing because of 2 separate interface modules in one enclosure
- Simple contact multiplication and reinforcement – also of safety modules
- Cost and space saving alternative compared to contactors
- Simple contact monitoring by forcibly guided contacts
- With pluggable terminal blocks for easy exchange of devices
Features
- With forcibly guided contacts according to IEC 61810-3
- Version with up to 2 x 4 contacts
- Variant to switch high DC-load
- Width: 22,5 mm
Datasheet Download
Interface module UG 3091

Product Overview
Advantages
- Simple contact multiplication and reinforcement also for safety modules
- Cost and space saving alternative compared to contactors
- Easy monitoring of contact state via forcibly guided NC contacts
Features
- According to IEC/EN 60 947-5-1
- With partially forcibly guided contacts according to IEC 61810-3
- 10 output contacts
- As option with pluggable terminal block for easy exchange of devices
– with screw terminals - 22,5 mm Baubreite
Datasheet Download
Interface module UG 3096

Product Overview
Advantages
- According to IEC/EN 60947-5-1
- Simple contact multiplication and reinforcement also for safety modules
- Cost and space saving alternative compared to contactors
- Easy monitoring of contact state via forcibly guided NC contacts
Features
- With forcibly guided contacts according to IEC 61810-3
- UG 3096: 8 output contacts
UH 3096: 16 output contacts - As option with gold plated contacts to switch low loads
- As option with contacts connected in series to switch high DC-loads
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals - UG 3096: Width 22.5 mm
UH 3096: Width 45 mm
Datasheet Download
Interface module HK 3087N

Product Overview
Advantages
- Simple contact extension and re-inforcement also of safety modules
- Cost and space saving alternative compared to contactors
- Simple contact monitoring via forcibly guided NC contact
- Large wire cross section 0.5 – 6 mm² (10 – 24 AWG) reduces thermal load on wires
Features
- According to IEC/EN 61810-1, IEC 60664-1,
- With forcibly guided contacts according to IEC 61810-3
- Models with soldered in PCB safety relay
- With polarity protected diode
- Optionally with free-wheeling diode across relay coil
- With LED indicator
- For DIN rail mounting according IEC/EN 60715
- Clearance and creepage distance between NC and NO contact > 10 mm
- Width 22,5 mm
Datasheet Download
Interface module HL 3096N

Product Overview
Advantages
- Simple contact extension and re-inforcement also of safety modules
- Cost and space saving alternative compared to contactors
- Simple contact monitoring via forcibly guided NC contact
- Large wire cross section 0.5 – 2.5 mm² (12-24 AWG) reduces thermal load on wires
Features
- According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1
- With forcibly guided contacts according to IEC 61810-3
- Models with soldered in or plug-in PCB safety relay consisting of:
– plug in socket HC 3096N and safety relay OA 5611
– plug in socket HL 3096N and safety relay OA 5612 - With polarity protected diode
- Optionally with free-wheeling diode across A1+ and A2
- Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
- For DIN rail mounting according IEC/EN 60715
- HC 3096N: width 18 mm
HL 3096N: width 36 mm
Datasheet Download
Interface module HL 3094N

Product Overview
Advantages
- Simple contact extension and re-inforcement also of safety modules
- Cost and space saving alternative compared to contactors
- Simple contact monitoring via forcibly guided NC contact
- Large wire cross section 0.5 – 2.5mm² (12-24 AWG) reduces thermal load on wires
Features
- Acc. to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1, EN 50155
- With forcibly guided contacts according to IEC 61810-3
- Models with soldered in or pluggable PCB safety relay, consisting of
– plug in socket HL 3094N and safety relay OA 5601 - With polarity protected diode
- With free-wheeling diode between A1+ and A2
- Optionally AgNi + 0.2 μm Au or AgNi + 5 μm Au
- For DIN rail mounting according DIN EN 60715
- Width: 36 mm
Datasheet Download
Interface module HL 3094

Product Overview
Features
- According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1
- With forcibly guided contacts according to IEC 61810-3
- Low nominal consumption: 0.75 W / 1 W / 1.25 W
- Max. 8 output contacts
- Contact material AgNi + 0.2 μm Au
- High thermal current Ith = 8 A
- Large temperature range: – 40 … + 55°C
- Safety relay soldered on PCB
- Optional AgNi + 5 μm Au or AgSnO + 0.2 μm Au
- Optional with free-wheeling diode across A1/A2
- Plug in relay option
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603 on socket HO 3095/10_ - DIN rail or srew mounting
- HL: 38 mm width
HO: 73.3 mm width
Datasheet Download
Interface module BD 3083/100

Product Overview
Advantages
- Simple contact monitoring via forcibly guided NC contact
Features
- According to IEC/EN 60 255, IEC/EN 61810-1
- Forcibly guided output contacts according to IEC 61810-3
- With LED indicator
- Width: 45 mm
Datasheet Download
Interface module UH 3096

Product Overview
Advantages
- According to IEC/EN 60947-5-1
- Simple contact multiplication and reinforcement also for safety modules
- Cost and space saving alternative compared to contactors
- Easy monitoring of contact state via forcibly guided NC contacts
Features
- With forcibly guided contacts according to IEC 61810-3
- UG 3096: 8 output contacts
UH 3096: 16 output contacts - As option with gold plated contacts to switch low loads
- As option with contacts connected in series to switch high DC-loads
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals - UG 3096: Width 22.5 mm
UH 3096: Width 45 mm
Datasheet Download
Interface module IP 3078

Product Overview
Product description
The coupling module IP 3078, SP 3078 can be used with its positively driven contacts for electrical decoupling of control and power levels as well as for contact multiplication and amplification. The coupling module can be easily adapted to the respective application by connecting the output contacts accordingly.
Features
- According to IEC/EN 60947-5-1, IEC/EN 61810-1
- Forcibly guided contacts according to IEC 61810-3
- Max. 6 output contacts
- High thermal current Ith = 8 A
- LED for operating state
- Devices available in 2 enclosure versions:
IP 3078: depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
SP 3078: depth 100 mm, with terminals at the top - Width 70 mm
Datasheet Download
Interface module SP 3078

Product Overview
Product description
The coupling module IP 3078, SP 3078 can be used with its positively driven contacts for electrical decoupling of control and power levels as well as for contact multiplication and amplification. The coupling module can be easily adapted to the respective application by connecting the output contacts accordingly
Features
- According to IEC/EN 60947-5-1, IEC/EN 61810-1
- Forcibly guided contacts according to IEC 61810-3
- Max. 6 output contacts
- High thermal current Ith = 8 A
- LED for operating state
- Devices available in 2 enclosure versions:
IP 3078: depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
SP 3078: depth 100 mm, with terminals at the top - Width 70 mm
Datasheet Download
Interface module HO 3094

Product Overview
Features
- According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1
- With forcibly guided contacts according to IEC 61810-3
- Low nominal consumption: 0.75 W / 1 W / 1.25 W
- Max. 8 output contacts
- Contact material AgNi + 0.2 μm Au
- High thermal current Ith = 8 A
- Large temperature range: – 40 … + 55°C
- Safety relay soldered on PCB
- Optional AgNi + 5 μm Au or AgSnO + 0.2 μm Au
- Optional with free-wheeling diode across A1/A2
- Plug in relay option
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603 on socket HO 3095/10_ - DIN rail or srew mounting
- HL: 38 mm width
HO: 73.3 mm width
Datasheet Download
Interface module HO 3095

Product Overview
Features
- According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60947-5-1
- With forcibly guided contacts according to IEC 61810-3
- Low nominal consumption: 0.75 W / 1 W / 1.25 W
- Max. 8 output contacts
- Contact material AgNi + 0.2 μm Au
- High thermal current Ith = 8 A
- Large temperature range: – 40 … + 55°C
- Safety relay soldered on PCB
- Optional AgNi + 5 μm Au or AgSnO + 0.2 μm Au
- Optional with free-wheeling diode across A1/A2
- Plug in relay option
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603 on socket HO 3095/10_ - DIN rail or srew mounting
- HL: 38 mm width
HO: 73.3 mm width