Switching device for safety-oriented safety mats and safety edges
Safety mat modules from DOLD to secure large hazardous areas and to serve as access controls to machines. These safety devices immediately stop hazardous movements when triggered by an actuating force, such as when a person steps on them, by issuing a control command that is conducted via the DOLD evaluation module. The safety mat modules are in accordance with safety category 4 / PL e as per DIN EN ISO 13849. Their functionality is continuously monitored and can be individually adjusted to the areas to be protected.
Safety mat switch gear BG 5925/910

Product Overview
Product description
- Protection of people and machines
- Emergency stop circuits on machines
- Monitoring of safety gates
- Switch gear for lightbars
- Switch gear for safety mats and safety edges
Features
- According to
– PL e and category 4 to EN ISO 13849-1
– maximum SIL 3 to EN IEC 62061
– SIL 3 to EN 61508 - Safety-mat switch gear with manual or automatic restart
- Can also be used for safety edges
- Output: max. 3 NO contacts
- Line fault detection on On-button
- Manual restart or automatic restart when connecting the supply voltage, switch S2
- LED indicator for state of operation
- Indicator for status of switching element
- LED indicator for channel 1 and 2
- Removable terminal strips
- Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2,5 mm2 stranded ferruled DIN 46 228-1/-2/-3/-4
- Width 22,5 mm
Datasheet Download
Safety edge module LG 5944

Product Overview
Advantages
- Current limitation protects the connected safety edge against electrical destruction by overcurrent and short circuit
- Universal usage with safety edges with different allowed switching currents (also for lower switching currents)
- Pluggable terminal blocks for easy exchange
Features
- According to
– Performance Level (PL) e and category 3 to EN ISO 13849-1
– SIL Claimed Level (maximum SIL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL) 3 to IEC/EN 61508 - Output: 2 redundant safety outputs
- Line fault detection on On-button
- Manual restart or automatic restart, switch S2
- Indication for operating condition
- LED indicator for channel 1 and 2
- As option with pluggable terminal blocks for easy exchange of devices
– With screw terminals
– Or with cage clamp terminals - Width: 22.5 mm