SAFEMASTER M – Decentralised, modular, freely configurable!
The modular safety system SAFEMASTER M is an optimal solution for many areas of machinery and system construction. The safety functions can be adjusted the respective requirements cost-effectively with software-free device configuration. SAFEMASTER M essentially consists of four modules: the control unit as well as the input, output and diagnosis module. The input module with freely selectable safety functions can be assigned to various output modules. The optional field bus connection allows the visualisation of the system status. The result is increased system availability.

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact - Parallel connection of several SAFEMASTER M-systems possible
- The functions are selected via rotary switch
– 1 Emergency stop circuit, 2-channel
– 2 Emergency stop circuits, single-channel
– 1 Emergency stop circuit, 2-channel + 1 stop single channel - Auto or manual start
- 2 semiconductor outputs for status indication
- LEDs for status indication
- Overvoltage and undervoltage monitoring function with error indication
- Permanently monitored feedback loop to connect external contactors
- Broken wire and short circuit monitoring function with error indication
- Width: 45 mm
Datasheet Download
Input module BG 5913.08/_0

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - Input module for realization of
– 4 similar 2-channel inputs
– Emergency stop circuits
– Safety gate monitoring system
– Two-hand control type IIIA, IIIC acc. to DIN/EN 574
– Light curtain (LC type 4) - The functions are selected via rotary switch
- 8 safety inputs
- 2 semiconductor outputs for status indication
- Broken wire and short circuit monitoring function with error indication
- LEDs for status indication
- Width:
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
Datasheet Download
Input module BG 5913.08/_1

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - Input module for realization of
– 4 mixed 2-channel inputs
– Emergency stop circuits
– Safety gate monitoring system
– Two-hand control type IIIA, IIIC acc. to DIN/EN 574
– Light curtain monitoring system (LC type 4) - The functions are selected via rotary switch
- 8 safety inputs
- 2 semiconductor outputs for status indication
- Broken wire and short circuit monitoring function with error indication
- LEDs for status indication
- Width: 22.5 mm
Datasheet Download
Input module BG 5913.08/_2

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - Input module for combination of 4 of the following functions to be set
via rotary switch:
– safety gate monitoring function (2 x 2 changeover contacts)
– Light curtain (LC type 4) with manual or automatic start
– Emergency stop (2-channel) with manual or automatic start
– Two-hand controls type IIIC acc. to DIN/EN 574 - Functions can be selected via rotary switches
- 8 inputs for safety sensors
- Broken wire and short circuit monitoring function with error indication
- 2 semiconductor outputs for status indication
- LEDs for status indication
- Width: 22.5 mm
Datasheet Download
Input module BG 5913.08/_3

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - Input module Combination of the following 3 functions:
– Light curtains (LC) type 4 with manual or automatic start
– E-stop 2-channel and manual or automatic start
– Two-hand function type IIIC according to DIN/EN 574 - The functions are selected via rotary switch
- 8 safety inputs
- 2 semiconductor outputs for status indication
- Broken wire and short circuit monitoring function with error indication
- LEDs for status indication
- Width: 22.5 mm
Datasheet Download
Input module BH 5913.08/_0

Product Overview
Features
- According to
- – Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- – Safety Integrity Level (SIL 3) to IEC/EN 61508
- Input module for realization of
- – 4 similar 2-channel inputs
- – Emergency stop circuits
- – Safety gate monitoring system
- – Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- – Light curtain (LC type 4)
- The functions are selected via rotary switch
- 8 safety inputs
- 2 semiconductor outputs for status indication
- Broken wire and short circuit monitoring function with error indication
- LEDs for status indication
- Width
- BG 5913.08/_0__: 22.5 mm
- BH 5913.08/_0__: 45 mm
Datasheet Download
Input module BG 5914.08/_0

Product Overview
Features
- According to:
– Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
– Safety Integrity Level (SIL 2) to IEC/EN 61508 - Input module for realization of:
– 8 E-STOP, single-channel, autostart
– 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
– 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut, autostart
– 8 E-STOP, single-channel, manual start
– 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
– 5 E-STOP, single-channel, + 1 E-STOP, 2-channel + 1 signal input, manual start
– As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected. - Broken wire and short circuit monitoring function with error indication
- 2 semiconductor outputs per function module for status indication
- LEDs for status indication
- Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
Datasheet Download
Input module BH 5914.08/_0

Product Overview
Features
- According to
– Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
– Safety Integrity Level (SIL 2) to IEC/EN 61508 - Input module for realization of:
– 8 E-STOP, single-channel, autostart
– 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
– 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut, autostart
– 8 E-STOP, single-channel, manual start
– 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
– 5 E-STOP, single-channel, + 1 E-STOP, 2-channel + 1 signal input, manual start
– As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected. - Broken wire and short circuit monitoring function with error indication
- 2 semiconductor outputs per function module for status indication
- LEDs for status indication
- Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
Datasheet Download
Input module BG 5915.08/_1

Product Overview
Features
- According to:
– Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL) 3 to IEC/EN 61508 - Input module with enabling inputs
- for connection of 2 channel
– safety gates
– e-stop buttons
– light curtain (LC) Type 4
– change over switch
– enabling swtich - Function combination and behaviour of enabling inputs selectable on
rotary switches - Broken wire and short circuit monitoring function with error indication
- 2 semiconductor outputs for status indication
- LEDs for status indication
- Width: 22.5 mm (BG 5915) or 45 mm (BH 5915)
Datasheet Download
Input module BH 5915.08/_1

Product Overview
Features
- According to
– Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL) 3 to IEC/EN 61508 - Input module with enabling inputs
- for connection of 2 channel
– safety gates
– e-stop buttons
– light curtain (LC) Type 4
– change over switch
– enabling swtich - Function combination and behaviour of enabling inputs selectable on
rotary switches - Broken wire and short circuit monitoring function with error indication
- 2 semiconductor outputs for status indication
- LEDs for status indication
- Width: 22.5 mm (BG 5915) or 45 mm (BH 5915)
Datasheet Download
Output module with output contacts BG 5912

Product Overview
Features
- According to
– Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
– SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
– Safety Integrity Level (SIL 3) to IEC/EN 61508 - Safety outputs can be assigned to one or several function modules
(control unit or input modules). - Outputs:
– 4 NO contacts
– 3 NO contacts, 1 NC contact
– 3 NO contacts 0-3 s delay-release time-delay relay
– 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay - Permanently monitored feedback loop for external contact reinforcement
- LEDs for status indication
- Width 22.5 mm
Datasheet Download
Diagnostic module for Profibus DP BH 5552

Product Overview
Features
- For transmitting the status information from the control unit and the input
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display - Electrical isolation
- Automatic recognition of transmission speed
- LED indicators for operating voltage and status
- Width of 45 mm