Timers On-delayed

You are here:

Time relays with contact delay for forward switching

With contact delayed time relays, the start is triggered by the activation of the operating voltage. The relay switches to the work position after the expiration of the configured delay time.

Timer, On-delay IK 7813

Features

  • Power ON-delay relay according to EN 61812-1
  • 1 changeover contact
  • Delay up to 60 min.
  • Repeat accuracy ≤ 1 %
  • LED indicator for contact position
  • Devices available in 2 enclosure versions:
    IK 7813: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 7813: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable ducts
  • Width 17.5 mm

Timer, On-delay IK 7814

Features

  • Power ON-delay relay according to EN 61812-1
  • 4 time ranges up to 640 min.
  • Repeat accuracy ≤ 1 %
  • LED indicator for contact position
  • 1 changeover contact
  • Devices available in 2 enclosure versions:
    IK 7814: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
    SK 7814: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable ducts
  • Width 17.5 mm
 

Timer, On-delay IK 7825

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay of 0.05 s … 60 min.
  • Repeat accuracy ≤ 0.5 % + 10 ms
  • Pushbutton for manual actuation of the contact
  • 1 or 2 changeover contacts for 16 A
  • Width 17.5 mm

Timer, On-delay IK 8808

Features

  • For two-wire technology
  • Power ON-delay relay according to EN 61812-1
  • Programmable time ranges between 0.06 … 160 s or 0.06 … 160 min
  • Programmable nominal voltage AC/DC 24 … 240 V
  • Repeat accuracy ≤ ± 1 %
  • Thyristor output for 10 … 800 mA
  • Width 17.5 mm

Timer, On-delay IK 9906

Features

  • Power ON-delay relay according to EN 61812-1
  • 8 time ranges from 0.05 s to 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • Adjustment aid for quick setting of long time values
  • Suitable for 2-wire proximity sensor control
  • 1 changeover contact
  • As option connection of a remote potentiometer 10 kΩ
  • As option with time interruption / time adding input
  • LED indicators for operation, contact position and time delay
  • Devices available in 2 enclosure versions:
    IK 9906: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 9906: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct.
  • 17.5 mm width

Timer, On-delay RK 7813

Advantages

  • Timers in compact design enclosures for consumer units
    – Timer RK 7813 on delayed
    – Timer RK 7814 on delayed
    – Fleeting action relay RK 7815
    – Flusher relay RK 7816

Features

  • According to IEC/EN 61812-1
  • RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
  • RK 7814: 4 time ranges up to 16 h
  • LED indicator for state of contact
  • Dual-voltage-version AC 230 V + AC/DC 24 V or AC 110 … 127 V + AC/DC 24 V
  • 1 changeover contact
  • As option units with second changeover contact (only for voltage AC 230 V + AC/DC 24 )
    – On delayed
    – As instantaneous contact
  • Start with impuls only for version RK 7816
  • Start with space only for version RK 7816._ _ /_10
  • Width: 17.5 mm

Timer, On-delay RK 7814

Advantages

  • Timers in compact design enclosures for consumer units
    – Timer RK 7813 on delayed
    – Timer RK 7814 on delayed
    – Fleeting action relay RK 7815
    – Flusher relay RK 7816

Features

  • According to IEC/EN 61812-1
  • RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
  • RK 7814: 4 time ranges up to 16 h
  • LED indicator for state of contact
  • Dual-voltage-version AC 230 V + AC/DC 24 V or AC 110 … 127 V + AC/DC 24 V
  • 1 changeover contact
  • As option units with second changeover contact (only for voltage AC 230 V + AC/DC 24 )
    – On delayed
    – As instantaneous contact
  • Start with impuls only for version RK 7816
  • Start with space only for version RK 7816._ _ /_10
  • Width: 17.5 mm

Timer, On-delay SK 7813

Features

  • Power ON-delay relay according to EN 61812-1
  • 1 changeover contact
  • Delay up to 60 min.
  • Repeat accuracy ≤ 1 %
  • LED indicator for contact position
  • Devices available in 2 enclosure versions:
    IK 7813: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 7813: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable ducts
  • Width 17.5 mm

Timer, On-delay SK 7814

Features

  • Power ON-delay relay according to EN 61812-1
  • 4 time ranges up to 640 min.
  • Repeat accuracy ≤ 1 %
  • LED indicator for contact position
  • 1 changeover contact
  • Devices available in 2 enclosure versions:
    IK 7814: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880
    SK 7814: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable ducts
  • Width 17.5 mm

Timer, On-delay SK 9906

Features

  • Power ON-delay relay according to EN 61812-1
  • 8 time ranges from 0.05 s to 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • Adjustment aid for quick setting of long time values
  • Suitable for 2-wire proximity sensor control
  • 1 changeover contact
  • As option connection of a remote potentiometer 10 kΩ
  • As option with time interruption / time adding input
  • LED indicators for operation, contact position and time delay
  • Devices available in 2 enclosure versions:
    IK 9906: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
    SK 9906: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct.
  • 17.5 mm width

Timer, On-delay BC 7930N

Features

  • Power ON-delay relay according to EN 61812-1
  • Time delay between 0.05 s … 10 h
  • Repeat accuracy ≤ 0.5 % + 10 ms
  • Dual voltage supply
  • LED indicator for contact position
  • 1 changeover contact
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
  • Width 22.5 mm

Timer, On-delay BC 7934N

Features

  • Power ON-delay relay according to EN 61812-1
  • 8 switching ranges from 0.05 s … 16 h
  • Infinite variable delay on every range 1 : 10
  • Dual-voltage design as standard (e.g. AC 230 V + AC/DC 24 V)
  • LED indicator for contact position
  • 1 changeover contact
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
  • Width 22.5 mm

Timer, On-delay MK 9906N

Advantages

  • 8 time ranges in one unit
  • Simplified storage
  • High accuracy
  • Quick setting of long time values

Features

  • Power ON-delay relay according to EN 61812-1
  • 8 time ranges from 0.05 s to 300 h selectable via rotational switches
  • Voltage range AC/DC 12 … 240 V
  • Adjustment aid for quick setting of long time values
  • Suitable for 2-wire proximity sensor control
  • 2 changeover contacts, one programmable as instantaneous contact
  • LED indicators for operation, contact position and time delay
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
  • As option connection of a remote potentiometer
  • As option with time interruption / time adding input
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • 22.5 mm width

Timer, On-delay MK 9906N/600

Advantages

  • For different time ranges
  • Simplified storage
  • High accuracy

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay from 0.05 s … 100 h
  • Repeat accuracy ≤ ± 0.5 %
  • Setting on absolute scale
  • LED indicators for operation and state of contacts
  • Controlled with 2-wire initiators
  • 2 changeover contacts
  • Wire connection: Also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
  • As option with pluggable terminal blocks for easy exchange of devices
    – With screw terminals
    – Or with cage clamp terminals
  • Width: 22.5 mm

Timer, On-delay AA 7512

Advantages

  • Non sensitive to electromagnetical influence by pneumatic time element

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 180 s
  • Repeat accuracy < ± 5 %
  • 1 changeover contact delayed, 1 changeover contact without delay
  • Width 45 mm

Timer, On-delay AA 7610

Advantages

  • Higher safety when connecting system parts during the start-up phase
  • High repeat accuracy
  • Large setting range
  • Simple unit setting
  • Purely mechanical timing

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % at range 6 s)
  • Time display
  • Delayed and instantaneous contact
  • As option no-voltage safe version
  • AA 7610: 45 mm
    EC 7610: Front surface 48 x 72 mm
    EF 7610: Front surface 72 x 72 mm

Timer, On-delay AA 7616

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • 6 switchable time ranges, adjustable on front side
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
  • Time lapse display
  • Switching position display (except for EH 7616)
  • With instantaneous contact
  • Available no-voltage safe
  • EF 7616: front side, protected against beam water, IP 65
  • AA 7616: width 45 mm
    EC 7616: front surface 48 x 72 mm
    EF 7616: front surface 72 x 72 mm
    EH 7616: front surface 96 x 96 mm

Timer, On-delay AA 9906/200

Features

  • Power ON-delay relay according to EN 61812-1
  • Time delay of 0.05 s … 60 min
  • Repeat accuracy ≤ ± 0.5 %
  • Adjustable on absolute scale
  • MK 9906 as a 2-voltage version
  • AA 9906/200 with wide input range AC/DC 24 … 240 V
  • Available with instantaneous contact
  • LED indicators for operation and contact position
  • Controllable by proximity sensors
  • 2 changeover contacts
  • MK 9906: width 22.5 mm
    AA 9906/200: width 45 mm

Timer, On-delay BA 7905

Advantages

  • Higher safety at connection of machine parts during start up
  • High repeat accuracy
  • Wide setting range
  • Easy setting

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 300 s
  • Repeat accuracy < ± 1 %
  • Voltage up to DC 220 V without series resistor
  • With remote potentiometer connection
  • With LED indication for operation and contact position
  • 1 or 2 changeover contacts
  • Width 45 mm

Timer, On-delay EC 7610

Advantages

  • Higher safety when connecting system parts during the start-up phase
  • High repeat accuracy
  • Large setting range
  • Simple unit setting
  • Purely mechanical timing

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % at range 6 s)
  • Time display
  • Delayed and instantaneous contact
  • As option no-voltage safe version
  • AA 7610: 45 mm
    EC 7610: Front surface 48 x 72 mm
    EF 7610: Front surface 72 x 72 mm

Timer, On-delay EC 7616

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • 6 switchable time ranges, adjustable on front side
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
  • Time lapse display
  • Switching position display (except for EH 7616)
  • With instantaneous contact
  • Available no-voltage safe
  • EF 7616: front side, protected against beam water, IP 65
  • AA 7616: width 45 mm
    EC 7616: front surface 48 x 72 mm
    EF 7616: front surface 72 x 72 mm
    EH 7616: front surface 96 x 96 mm

Timer, On-delay EF 7610

Advantages

  • Higher safety when connecting system parts during the start-up phase
  • High repeat accuracy
  • Large setting range
  • Simple unit setting
  • Purely mechanical timing

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % at range 6 s)
  • Time display
  • Delayed and instantaneous contact
  • As option no-voltage safe version
  • AA 7610: 45 mm
    EC 7610: Front surface 48 x 72 mm
    EF 7610: Front surface 72 x 72 mm

Timer, On-delay EF 7616

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • 6 switchable time ranges, adjustable on front side
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
  • Time lapse display
  • Switching position display (except for EH 7616)
  • With instantaneous contact
  • Available no-voltage safe
  • EF 7616: front side, protected against beam water, IP 65
  • AA 7616: width 45 mm
    EC 7616: front surface 48 x 72 mm
    EF 7616: front surface 72 x 72 mm
    EH 7616: front surface 96 x 96 mm

Timer, On-delay EH 7616

Features

  • Power ON-delay relay according to EN 61812-1
  • Delay up to 60 h
  • 6 switchable time ranges, adjustable on front side
  • Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
  • Time lapse display
  • Switching position display (except for EH 7616)
  • With instantaneous contact
  • Available no-voltage safe
  • EF 7616: front side, protected against beam water, IP 65
  • AA 7616: width 45 mm
    EC 7616: front surface 48 x 72 mm
    EF 7616: front surface 72 x 72 mm
    EH 7616: front surface 96 x 96 mm

For all your automation project needs: