SMX Compact base modules include: SMX 10/2, SMX 10A/2, SMX 11/2, SMX 11-2/2, SMX 11-PXV/2, SMX 12/2, SMX 12A/2, SMX 12-2/2, SMX 12-2A/2, SMX 12-1-PXV/2
i

SMX 10/2
Free programmable and configurable compact-type safety controller
- 14 Safe digital inputs
- 2 Safe relay outputs
- 2 Pulse outputs
- 2/4 pn- or pp-switching outputs
- Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- optional: safe/non-safe communication interface
Variants
SMX 10/2/D | Free programmable and configurable compact-type safety controller
|
SMX 10/2/DNM | Free programmable and configurable compact-type safety controller
|
SMX 10/2/xNM | Free programmable and configurable compact-type safety controller
|
SMX 10/2/xxM | Free programmable and configurable compact-type safety controller
|
SMX 10/2/DBM | Free programmable and configurable compact-type safety controller
|
SMX 10/2/xBM | Free programmable and configurable compact-type safety controller
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
• max. 42 safe digital inputs,
• max. 12 safe digital outputs,
• max. 20 safe digital I/O‘s,
• max. 11 safe relay outputs,
• max. 10 auxiliary outputs - Logic processing up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
- Freely programmable for safe processing of EMERGENCY STOP pushbutton, two-hand control, light grid, operating mode selector switch, etc.
- Function-plan oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Monitored relay outputs for safety relevant functions
- Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Status monitoring by coded 7-segment-display and status LEDs
- Multifunction button (quit, start, reset) can be operated from the front side
- Configurable via SafePLC² Seriel USB-adapter or Ethernet-based fieldbus
- Optional: Communication interface:
- Standard and safe field bus protocols for communication with a higher level controller
(PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE) - Safe cross communication (SMMC) for data exchange between multiple base devices
- Field bus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchnage with distrubted I/O systems
- Standard and safe field bus protocols for communication with a higher level controller
- The mechanical construction of the SMX10/2 (/x*) is dependent on the respective forms of the base module
* Optional: integrated communication interface (/DNM, /DBM)
|

SMX 10A/2
Free programmable and configurable compact safety conttroller with analog option
- 14 safe digital inputs
- 2 safe analog inputs (voltage + current)
- Up to 5 safe switch-off channels
- 2 auxiliary outputs
- Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- optional: safe/non-safe fieldbus interface
Variants

SMX 10A-I/2
Free programmable and configurable compact-type safety controller
- 14 Safe digital inputs
- 2 Safe relay outputs
- up to 5 safe switch-off channels
- 2 Auxiliary outputs
- Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- optional: safe / non-safe fieldbus interface
- 2 Safe analog inputs (current)
|

SMX 11/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for 1 axis
- 3 encoder interfaces*
- 14 safe digital inputs
- up to 4 safe digital outputs
- Up to 5 safe switch-off channels
- Small safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
|

SMX 11-2/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for 1 axis with extended encoder functionality
- 5 encoder interfaces*
- 14 safe digital inputs
- Up to 5 safe switch-off channels
- Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 42 safe digital inputs,
- max. 12 safe digital outputs,
- max. 20 safe digital I/O‘s,
- max. 9 safe relay outputs,
- max. 10 auxiliary outputs,
- max. 1 safe axis
- Logic processing upto PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
- Movement monitoring for one axis up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
- Speed monitoring:
- RPM-monitoring
- Standstill monitoring
- Sense of rotation monitoring
- Safe incremental dimension
- Emergency Stop monitoring
- Position monitoring
- Position range monitoring
- Trend range monitoring
- Target position monitoring
- Freely programmable modular controller for up to 800 IL instructions
- Logic diagram oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact mon itoring of connected switchgear (EMU)
- Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
- Monitored relay outputs for safety relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Coded status display via front-side 7 segment display and status LEDs
- Multifunction button (quit, start, reset) can be operated from the front side
- Configurable via SafePLC² über USB serial adapter or ethernet based field bus
- Extended functionality:
- allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
- 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
- Optional: integrated Communication interface :
- Standard and safe field bus protocols for communication with a higher level controller
(PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE) - Safe cross communication (SMMC) for data exchange between multiple base devices
- Field bus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchange with distributed I/O systems
- Standard and safe field bus protocols for communication with a higher level controller
- The mechanical structure of SMX11-2/2 (/x*) is depended on the respective forms of the base module
* Optional: integrated communication interface (/DNM, /DBM)
|

SMX 11-PXV/2
Open programmable compact safety controller
- Integrated movement monitoring of one axis with one safePXV-encoder interface
- 14 safe digital inputs
- Up to 4 safe digital outputs
- 2 Relay outputs
- Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
- optional: safe/non-safe fieldbus interface
Variants
SMX11-PXV/2/D | Open programmable compact safety controller
|
SMX11-PXV/2/DNM | Open programmable compact safety controller
|
SMX11-PXV/2/xNM | Open programmable compact safety controller
|
SMX11-PXV/2/xxM | Open programmable compact safety controller
|
SMX11-PXV/2/DBM | Open programmable compact safety controller
|
SMX11-PXV/2/xBM | Open programmable compact safety controller
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 42 safe digital inputs
- max. 12 safe digital outputs
- max. 20 safe digital I/O‘s
- max. 9 safe relay outputs
- max. 10 auxiliary outputs
- max. 1 safe axis
- Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, light grids, mode selectors, etc.
- Complete speed and position-related safety functions for drive monitoring IEC 61800-5-2 integrated into firmware
- Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
- Speed monitoring
- Standstill monitoring
- Direction monitoring
- Safe incremental dimension
- Emergency Stop monitoring
- Position monitoring
- Position range monitoring
- Trend range monitoring
- Target position monitoring
- Open programmable for up to 800 IL-instructions
- Logic diagram oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
- Monitored relay outputs for safety relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Coded status display via front-side 7 segment display and status LEDs
- Multifunction button (quit, start, reset), operated from the front side
- Configurable via SafePLC² über USB serial adapter or ethernet based fieldbus
- Extended functionality: SafePXV-encoder interface
- Integrated Memory Card
- Optional: integrated Communication interface:
- Standard and safe fieldbus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between multiple base devices
- Field bus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchange with distributed I/O systems
- The mechanical structure of SMX11-PXV/2 (/x*) is depended on the respective form of the base module
* Optional: integrated communication interface (/DNM, /DBM)
|

SMX 12/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes
- 4 encoder interfaces*
- 14 safe digital inputs
- Up to 5 safe switch-off channels
- Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
|

SMX 12-2/2
Freely programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes with extended encoder functionality
- 8 Encoder interfaces
- 14 Safe digital inputs
- Up to 5 safe switch-off channels
- Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
SMX 12-2/2/D | Freely programmable and configurable compact safety controller
|
SMX 12-2/2/DNM | Freely programmable and configurable compact safety controller
|
SMX 12-2/2/xNM | Freely programmable and configurable compact safety controller
|
SMX 12-2/2/xxM | Freely programmable and configurable compact safety controller
|
SMX 12-2/2/DBM | Freely programmable and configurable compact safety controller
|
SMX 12-2/2/xBM | Freely programmable and configurable compact safety controller
|
Characteristic of the module
Characteristic of the module
- Expandable up to:
- max. 42 safe digital inputs,
- max. 12 safe digital outputs,
- max. 20 safe digital I/Os,
- max. 9 safe relay outputs,
- max. 10 auxiliary outputs,
- max. 2 safe axes
- Freely programmable for the safe processing of emergency stop buttons, two-hand operation, light curtains, operating mode selector switches, etc.
- Complete speed and position-related safety functions for drive monitoring of one or two axes
- Speed monitoring
- Standstill monitoring
- Direction of rotation monitoring
- Safe increment
- Emergency stop monitoring
- Position monitoring
- Position/travel range monitoring
- Target position monitoring
- Freely programmable small controller for up to 800 AWL instructions
- Function plan-oriented programming using SafePLC2
- Pulse outputs for cross-circuit detection of digital input signals
- External contact monitoring of connected switching devices (EMU)
- Switchable safe outputs pn-, pp-switching for safety-relevant functions
- Monitored relay outputs for safety-relevant functions
- Extensive diagnostic functions integrated
- Parameter management for expansion modules in the base module
- Coded status display via 7-segment display on the front and status LEDs
- Multifunction button (Quit, Start, Reset) can be operated from the front
- Configurable with SafePLC2 via USB serial adapter or Ethernet-based fieldbus
- Extended functionality:
- Allows the connection of up to 2 encoders per axis (SSI, TTL, HTL proximity sensor)
- Extended encoder interface additionally supports a high-resolution HTL (200 kHz), sin/cos high-resolution and resolver
- Optional: integrated communication interface :
- Standard and safe fieldbus protocols for communication with a higher-level controller (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross-communication (SMMC) for data exchange between several base devices
- Fieldbus protocols with the same hardware can be switched using SafePLC2
- Safe remote IO communication for data exchange with distributed IO systems
- The mechanical structure of the SMX12-2/2 (/x*) depends on the respective version of the base module
* Optional: integrated communication interface (/DNM, /DBM)
|

SMX 12-2A/2
Freely programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes with extended encoder functionality
- 8 encoder interfaces
- 14 safe digital inputs
- 2 safe analog inputs
- Up to 5 safe switch-off channels
- Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Characteristic of the module
Characteristic of the module
- Expandable up to:
- max. 42 safe digital inputs,
- max. 12 safe digital outputs,
- max. 20 safe digital I/Os,
- max. 9 safe relay outputs,
- max. 10 auxiliary outputs,
- max. 2 safe axes
- Freely programmable for the safe processing of emergency stop buttons, two-hand operation, light curtains, operating mode selector switches, etc.
- Complete speed and position-related safety functions for drive monitoring of one or two axes
- Speed monitoring
- Standstill monitoring
- Direction of rotation monitoring
- Safe increment
- Emergency stop monitoring
- Position monitoring
- Position/travel range monitoring
- Target position monitoring
- Function plan-oriented programming using SafePLC2
- Pulse outputs for cross-circuit detection of digital input signals
- External contact monitoring of connected switching devices (EMU)
- Switchable safe outputs pn-, pp-switching for safety-relevant functions
- Monitored relay outputs for safety-related functions
- Extensive diagnostic functions integrated
- Parameter management for expansion modules in the base module
- Coded status display via 7-segment display on the front and status LEDs
- Multifunction button (Quit, Start, Reset) can be operated from the front
- Configurable with SafePLC2 via USB serial adapter or Ethernet-based fieldbus
- Extended functionality:
- Allows the connection of up to 2 encoders per axis (SSI, TTL, HTL proximity sensor)
- Extended encoder interface also supports a high-resolution HTL (200 kHz), sin/cos high-resolution and resolver
- Optional: integrated communication interface:
- Standard and safe fieldbus protocols for communication with a higher-level controller (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between several base devices
- Fieldbus protocols with the same hardware can be switched using SafePLC2
- Safe remote IO communication for data exchange with distributed IO systems
- The mechanical design of the SMX12-2A/2 (/x*) depends on the respective version of the base module
* Optional: integrated communication interface (/DNM, /DBM)
|

SMX12-1-PXV/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes
- 6 Encoder interfaces (with one safePXV encoder interface)
- 14 safe digital inputs
- Up to 5 safe switch-off channels
- Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
SMX12-1-PXV/2/D | Free programmable and configurable compact safety controller
|
SMX12-1-PXV/2/DNM | Free programmable and configurable compact safety controller
|
SMX12-1-PXV/2/xNM | Free programmable and configurable compact safety controller
|
SMX12-1-PXV/2/xxM | Free programmable and configurable compact safety controller
|
SMX12-1-PXV/2/DBM | Free programmable and configurable compact safety controller
|
SMX12-1-PXV/2/xBM | Free programmable and configurable compact safety controller
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 42 safe digital inputs
- max.12 safe digitale outputs
- max. 20 safe digital I/O‘s
- max. 9 safe relay outputs
- max. 10 auxiliary outputs
- max. 2 safe axis
- Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, Light grids, mode selectors, etc.
- Complete speed and position-related safety functions for drive monitoring for one or two axes
- Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
- Speed monitoring
- Standstill monitoring
- Direction monitoring
- Safe incremental dimension
- Emergency Stop monitoring
- Position monitoring
- Position range monitoring
- Trend range monitoring
- Target position monitoring
- Logic diagram oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact mon itoring of connected switchgear (EMU)
- Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
- Monitored relay outputs for safety relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Coded status display via front-side 7 segment display and status LEDs
- Multifunction button (quit, start, reset) operated from the front side
- Configurable via SafePLC² über USB serial adapter or ethernet based field bus
- Extended functionality: SafePXV-encoder interface
- Integrated Memory Card
- Extended functionality:
- allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
- 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
- Optional: integrated Communication interface :
- Standard and safe field bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between multiple base devices
- Field bus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchange with distributed I/O systems
- The mechanical structure of SMX12-1-PXV/2 (/x*) is depended on the respective form of the base module
* Optional: integrated communication interface (/DNM, /DBM)