Compact Base Modules

You are here:

SMX Compact base modules include: SMX 10/2, SMX 10A/2, SMX 11/2, SMX 11-2/2, SMX 11-PXV/2, SMX 12/2, SMX 12A/2, SMX 12-2/2, SMX 12-2A/2, SMX 12-1-PXV/2

 

i

SMX 10/2

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • optional: safe/non-safe communication interface

SMX 10/2/D

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe communication interface
  • Decentral communication

SMX 10/2/DNM

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 10/2/xNM

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 10/2/xxM

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Memory Card for safety program

SMX 10/2/DBM

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 10/2/xBM

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • 2 Pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for saftey program

Characteristic of the module

  • Extendable up to:
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/O‘s,
    • max. 11 safe relay outputs,
    • max. 10 auxiliary outputs
  • Logic processing up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Freely programmable for safe processing of EMERGENCY STOP pushbutton, two-hand control, light grid, operating mode selector switch, etc.
  • Function-plan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Monitored relay outputs for safety relevant functions
  • Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Status monitoring by coded 7-segment-display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² Seriel USB-adapter or Ethernet-based fieldbus
  • Optional: Communication interface:
    • Standard and safe field bus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchnage with distrubted I/O systems
  • The mechanical construction of the SMX10/2 (/x*) is dependent on the respective forms of the base module

* Optional: integrated communication interface (/DNM, /DBM)

|

SMX 10A/2

Free programmable and configurable compact safety conttroller with analog option

  • 14 safe digital inputs
  • 2 safe analog inputs (voltage + current)
  • Up to 5 safe switch-off channels
  • 2 auxiliary outputs
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • optional: safe/non-safe fieldbus interface

SMX 10A-I/2

Free programmable and configurable compact-type safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs
  • up to 5 safe switch-off channels
  • 2 Auxiliary outputs
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • optional: safe / non-safe fieldbus interface
  • 2 Safe analog inputs (current)

|

SMX 11/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for 1 axis
  • 3 encoder interfaces*
  • 14 safe digital inputs
  • up to 4 safe digital outputs
  • Up to 5 safe switch-off channels
  • Small safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

|

SMX 11-2/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for 1 axis with extended encoder functionality
  • 5 encoder interfaces*
  • 14 safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

Characteristic of the module

  • Extendable up to:
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/O‘s,
    • max. 9 safe relay outputs,
    • max. 10 auxiliary outputs,
    • max. 1 safe axis
  • Logic processing upto PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Movement monitoring for one axis up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
  • Speed monitoring:
  • RPM-monitoring
  • Standstill monitoring
  • Sense of rotation monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Freely programmable modular controller for up to 800 IL instructions
  • Logic diagram oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact mon itoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² über USB serial adapter or ethernet based field bus
  • Extended functionality:
    • allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
    • 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
  • Optional: integrated Communication interface :
    • Standard and safe field bus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchange with distributed I/O systems
  • The mechanical structure of SMX11-2/2 (/x*) is depended on the respective forms of the base module

* Optional: integrated communication interface (/DNM, /DBM)

|

SMX 11-PXV/2

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • optional: safe/non-safe fieldbus interface

SMX11-PXV/2/D

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • Decentral communication (/D)

SMX11-PXV/2/DNM

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • Decentral communication
  • Ethernet based fieldbus interface, safe / non-safe
  • MemoryCard for safety program
  • optional: with FSoE

SMX11-PXV/2/xNM

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • Ethernet based fieldbus interface, safe / non-safe
  • MemoryCard for safety program
  • Optional: with FSoE

SMX11-PXV/2/xxM

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • MemoryCard for safety program

SMX11-PXV/2/DBM

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • Decentral communication
  • CAN based fieldbus interface, safe / non-safe
  • MemoryCard for safety program

SMX11-PXV/2/xBM

Open programmable compact safety controller

  • Integrated movement monitoring of one axis with one safePXV-encoder interface
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • 2 Relay outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • CAN based fieldbus interface, safe / non-safe
  • MemoryCard for safety program

Characteristic of the module

  • Extendable up to:
    • max. 42 safe digital inputs
    • max. 12 safe digital outputs
    • max. 20 safe digital I/O‘s
    • max. 9 safe relay outputs
    • max. 10 auxiliary outputs
    • max. 1 safe axis
  • Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, light grids, mode selectors, etc.
  • Complete speed and position-related safety functions for drive monitoring IEC 61800-5-2 integrated into firmware
  • Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
  • Speed monitoring
  • Standstill monitoring
  • Direction monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Open programmable for up to 800 IL-instructions
  • Logic diagram oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction button (quit, start, reset), operated from the front side
  • Configurable via SafePLC² über USB serial adapter or ethernet based fieldbus
  • Extended functionality: SafePXV-encoder interface
  • Integrated Memory Card
  • Optional: integrated Communication interface:
    • Standard and safe fieldbus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchange with distributed I/O systems
  • The mechanical structure of SMX11-PXV/2 (/x*) is depended on the respective form of the base module

* Optional: integrated communication interface (/DNM, /DBM)

|

SMX 12/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 4 encoder interfaces*
  • 14 safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

|

SMX 12-2/2

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

SMX 12-2/2/D

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication

SMX 12-2/2/DNM

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 12-2/2/xNM

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 12-2/2/xxM

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Memory Card for safety program

SMX 12-2/2/DBM

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 12-2/2/xBM

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 Encoder interfaces
  • 14 Safe digital inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

Characteristic of the module

  • Expandable up to:
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/Os,
    • max. 9 safe relay outputs,
    • max. 10 auxiliary outputs,
    • max. 2 safe axes
  • Freely programmable for the safe processing of emergency stop buttons, two-hand operation, light curtains, operating mode selector switches, etc.
  • Complete speed and position-related safety functions for drive monitoring of one or two axes
  • Speed monitoring
  • Standstill monitoring
  • Direction of rotation monitoring
  • Safe increment
  • Emergency stop monitoring
  • Position monitoring
  • Position/travel range monitoring
  • Target position monitoring
  • Freely programmable small controller for up to 800 AWL instructions
  • Function plan-oriented programming using SafePLC2
  • Pulse outputs for cross-circuit detection of digital input signals
  • External contact monitoring of connected switching devices (EMU)
  • Switchable safe outputs pn-, pp-switching for safety-relevant functions
  • Monitored relay outputs for safety-relevant functions
  • Extensive diagnostic functions integrated
  • Parameter management for expansion modules in the base module
  • Coded status display via 7-segment display on the front and status LEDs
  • Multifunction button (Quit, Start, Reset) can be operated from the front
  • Configurable with SafePLC2 via USB serial adapter or Ethernet-based fieldbus
  • Extended functionality:
    • Allows the connection of up to 2 encoders per axis (SSI, TTL, HTL proximity sensor)
    • Extended encoder interface additionally supports a high-resolution HTL (200 kHz), sin/cos high-resolution and resolver
  • Optional: integrated communication interface :
    • Standard and safe fieldbus protocols for communication with a higher-level controller (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross-communication (SMMC) for data exchange between several base devices
    • Fieldbus protocols with the same hardware can be switched using SafePLC2
    • Safe remote IO communication for data exchange with distributed IO systems
  • The mechanical structure of the SMX12-2/2 (/x*) depends on the respective version of the base module

* Optional: integrated communication interface (/DNM, /DBM)

|

SMX 12-2A/2

Freely programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes with extended encoder functionality
  • 8 encoder interfaces
  • 14 safe digital inputs
  • 2 safe analog inputs
  • Up to 5 safe switch-off channels
  • Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

Characteristic of the module

  • Expandable up to:
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/Os,
    • max. 9 safe relay outputs,
    • max. 10 auxiliary outputs,
    • max. 2 safe axes
  • Freely programmable for the safe processing of emergency stop buttons, two-hand operation, light curtains, operating mode selector switches, etc.
  • Complete speed and position-related safety functions for drive monitoring of one or two axes
  • Speed monitoring
  • Standstill monitoring
  • Direction of rotation monitoring
  • Safe increment
  • Emergency stop monitoring
  • Position monitoring
  • Position/travel range monitoring
  • Target position monitoring
  • Function plan-oriented programming using SafePLC2
  • Pulse outputs for cross-circuit detection of digital input signals
  • External contact monitoring of connected switching devices (EMU)
  • Switchable safe outputs pn-, pp-switching for safety-relevant functions
  • Monitored relay outputs for safety-related functions
  • Extensive diagnostic functions integrated
  • Parameter management for expansion modules in the base module
  • Coded status display via 7-segment display on the front and status LEDs
  • Multifunction button (Quit, Start, Reset) can be operated from the front
  • Configurable with SafePLC2 via USB serial adapter or Ethernet-based fieldbus
  • Extended functionality:
    • Allows the connection of up to 2 encoders per axis (SSI, TTL, HTL proximity sensor)
    • Extended encoder interface also supports a high-resolution HTL (200 kHz), sin/cos high-resolution and resolver
  • Optional: integrated communication interface:
    • Standard and safe fieldbus protocols for communication with a higher-level controller (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between several base devices
    • Fieldbus protocols with the same hardware can be switched using SafePLC2
    • Safe remote IO communication for data exchange with distributed IO systems
  • The mechanical design of the SMX12-2A/2 (/x*) depends on the respective version of the base module

* Optional: integrated communication interface (/DNM, /DBM)

|

SMX12-1-PXV/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

SMX12-1-PXV/2/D

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication (/D)

SMX12-1-PXV/2/DNM

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • Ethernet based fieldbus interface, safe / non-safe
  • MemoryCard for safety program
  • optional: with FSoE

SMX12-1-PXV/2/xNM

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet based fieldbus interface, safe / non-safe
  • MemoryCard for safety program

SMX12-1-PXV/2/xxM

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • MemoryCard for safety program

SMX12-1-PXV/2/DBM

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • CAN based fieldbus interface, safe / non-safe
  • MemoryCard for safety program

SMX12-1-PXV/2/xBM

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN based fieldbus interface, safe / non-safe
  • MemoryCard for safety program

Characteristic of the module

  • Extendable up to:
    • max. 42 safe digital inputs
    • max.12 safe digitale outputs
    • max. 20 safe digital I/O‘s
    • max. 9 safe relay outputs
    • max. 10 auxiliary outputs
    • max. 2 safe axis
  • Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, Light grids, mode selectors, etc.
  • Complete speed and position-related safety functions for drive monitoring for one or two axes
  • Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
  • Speed monitoring
  • Standstill monitoring
  • Direction monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Logic diagram oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact mon itoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction button (quit, start, reset)  operated from the front side
  • Configurable via SafePLC² über USB serial adapter or ethernet based field bus
  • Extended functionality: SafePXV-encoder interface
  • Integrated Memory Card
  • Extended functionality:
    • allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
    • 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
  • Optional: integrated Communication interface :
    • Standard and safe field bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchange with distributed I/O systems
  • The mechanical structure of SMX12-1-PXV/2 (/x*) is depended on the respective form of the base module

* Optional: integrated communication interface (/DNM, /DBM)