Multifunctional safety relays

You are here:

SAFEMASTER C – Safety plus multifunctionality

Whether it is used as an individual device or integrated in complex safety systems – with SAFEMASTER C, you always have the right solution for protecting people and machinery. With the compact multifunctional safety switching devices from DOLD, various safety-oriented inputs, such as emergency stop, safety door, et cetera, are assigned to a single output. An additional important advantage of SAFEMASTER C is the cost-savings as a result of its multifunctionality: through taking up less space in the control cabinet than monofunctional safety devices, through reduced storage needs and through the simple and fast calibration of the safety functions and operating modes.

Multifunctional safety timer with instantaneous contacts UG 6960

Advantages

  • Various delay functions adjustable at device:
    – Release delay
    – Release delay retriggerable
    – On delay
    – Fleeting on make / break
    – Delay function settable via potentiometer
  • Various safety functions defined:
    – E-Stop
    – Safety gate
    – Two-hand control
    – Safety mat / Safety edge
    – Exclusive or contacts
    – Light curtain
  • Manual or auto start
  • Instantaneous contact and safety delayed contacts
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: 2 NO instantaneous contact and 2 NO contacts delayed
  • 1 semiconductor output for instantaneous contacts
    1 semiconductor output for delayed contacts
  • LED indicator for operation, safety function, time delay and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • Width: 22.5 mm

Multifunctional safety timer UG 6961

Advantages

  • Various delay functions adjustable at device:
    – Release delay
    – Release delay retriggerable
    – On delay
    – Fleeting on make / break
    – Delay function settable via potentiometer
  • Various safety functions defined:
    – E-Stop
    – Safety gate
    – Two-hand control
    – Safety mat / Safety edge
    – Exclusive or contacts
    – Light curtain
  • Manual or auto start
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: max. 4 NO instantaneous semiconductor monitoring output
  • LED indicator for operation, delay contects and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • Width: 22.5 mm

Multifunctional safety module UG 6970

Advantages

  • 2 independent, separately adjustable safety funcions:
    – E-Stop
    – Safety gate
    – Two-hand control
    – Safety mat / Safety edge
    – Exclusive or contacts
    – Light curtain
  • Only one device, two safety functions at the same time
  • Manual or auto start
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: 2 NO contacts per safety function
  • 1 semiconductor output per safety function
  • LED indicator for operation, safety function 1, 2 and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • Width: 22.5 mm

Multifunctional safety module UG 6980

Advantages

  • Adjustable safety functions:
    – E-Stop
    – Safety gate
    – Two-hand control
    – Safety mat / Safety edge
    – Exclusive or contacts
    – Light curtain
  • Manual or auto start
  • Only one device, different safety functions
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: max. 4 NO instantaneous semiconductor monitoring output
  • LED indicator for operation, delay contects and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    – with screw terminals
    – or with cage clamp terminals
  • Width: 22.5 mm

Multifunction safety module BH 5910

Features

  • According to
    – Performance Level (PL) e and category 4 to EN ISO 13849-1
    – SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    – Safety Integrity Level (SIL 3) to IEC/EN 61508
  • Functions selectable via rotational switches to connect max.:
    – 8 E-stop circuits, single channel or
    – 4 E-stop circuits, 2-channel or
    – 4 light curtains or
    – 2 light curtains and 1 E-stop circuit or
    – 4 safety gates or
    – 2 safety gates and 1 E-stop circuit or
    – 4 pairs of 2-hand-buttons or Typ III A according to EN ISO 13851 or
    – 2 pairs of 2-hand-buttons Typ III C according to EN ISO 13851 and 1 E-stop circuit
  • In addition selectable:
    – Auto or manual reset (simulation input for gate monitor)
    – Continuously monitored feedback circuit to monitor external contactors
  • Cross fault detection
  • Short circuit and broken wire detection
  • Outputs:
    – 3 NO or 2 NO and 1 NC contacts
    – 2 semiconductor outputs short circuit proof and overload protected
  • Under- and overvoltage detection and signalling
  • LED indication for operation (RUN), channel 1/2
  • 45 mm width

For all your automation project needs:

Get in touch with us today!