Safety relays with forcibly guided contacts

You are here:
Relay with mechanically forcibly guided contacts

Safety technology is becoming increasingly important in mechanical and plant engineering. Safety modules or even safety controllers are used everywhere. Despite the increasing use of semiconductors, electromechanical relays are still an important component. 

Next Product

Safety relays OA 5669

Product description

  • Switchgear for safety technology
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology

Technical specifications

Contact equipping:2
Continuous current:2 x 5 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,8 – 1,6
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:29 x 13 x 25,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 70 °C
Type acc. to DIN EN 61810-3:A/B
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5669

Safety relays OA 5669/3___

Product description

  • Switchgear for safety technology
  • Press controls

Technical specifications

Contact equipping:2
Continuous current:2 x 5 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,4
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:29 x 13 x 25,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A/B
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5669/3___

Safety relays OA 5667

Product description

  • Switchgear for safety applications
  • Press controls

Technical specifications

Contact equipping:2
Continuous current:2 x 6 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,3
Protection type:RT II (flux-proof relay)
Size L x W x H:37 x 25 x 10,8 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A/B
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5667

Safety relays OA 5667/____4

Product description

  • Switchgear for safety technology
  • Press controls

Technical specifications

Contact equipping:2
Continuous current:2 x 6 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,3
Protection type:RT II (flux-proof relay)
Size L x W x H:27 x 25 x 10,8 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A/B
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5667/_____4

Safety relays OA 5670

Product description

  • Switchgear for safety technology
  • Press controls

Technical specifications

Contact equipping:4
Continuous current:3 x 6 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,4
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:35 x 13 x 25,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 75 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5670

Safety relays OA 5611

Product description

  • To be used in circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:4
Continuous current:3 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,4
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:41,9 x 14,5 x 30,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5611

Safety relays OA 5611/___S

Product description

  • To be used in electrical circuits for safety applications.
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:4
Continuous current:3 x 6 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,8
Protection type:RT II (flux-proof relay)
Size L x W x H:41,9 x 14,5 x 30,35 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5611/____S

Safety relays, according DIN EN 50578 OA 5611/31__L1

Product description

  • To be used in electrical circuits for safety applications.
  • For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004)

Technical specifications

Contact equipping:4
Continuous current:3 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,4
Protection type:RT II (flux-proof relay)
Size L x W x H:41,9 x 14,5 x 30,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 70 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5611/31__L1

Safety relays OA 5612

Product description

  • To be used in circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:6
Continuous current:5 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,4
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:51,5 x 14,5 x 30,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5612

Safety relays, sensitiv OA 5612/____S

Product description

  • To be used in electrical circuits for safety applications.
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:6
Continuous current:5 x 6 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,8
Protection type:RT II (flux-proof relay)
Size L x W x H:51,5 x 14,5 x 30,35 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5612/____S

Safety relays OA 5621

Product description

  • To be used in electrical circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology
  • Medical technology

Technical specifications

Contact equipping:4
Continuous current:3 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,4
Protection type:RT III (wash-tight)
Size L x W x H:46,5 x 22 x 15,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 80 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5621

Safety relays with double contacts OA 5621_D

Product description

  • To be used in electrical circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:4
Continuous current:3 x 5 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,2
Protection type:RT III (wash-tight)
Size L x W x H:46,5 x 22 x 15,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 80 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgNi + 5 µm Au
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5621_D

Safety relays OA 5622

Product description

  • To be used in electrical circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology
  • Medical technology

Technical specifications

Contact equipping:6
Continuous current:5 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,4
Protection type:RT III (wash-tight)
Size L x W x H:55 x 22 x 15,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 80 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5622

Safety relays with double contacts OA 5622_D

Product description

  • To be used in electrical circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology

Technical specifications

Contact equipping:6
Continuous current:5 x 5 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,2
Protection type:RT III (wash-tight)
Size L x W x H:55 x 22 x 15,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 80 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgNi + 5 µm Au
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5622_D

Safety relays OA 5623

Product description

  • Railway and signalling applications
  • Automation
  • Medical devices
  • Radio- and telecontrol applications
  • Fuel applications
  • Process applications
  • Elevator applications

Technical specifications

Contact equipping:8
Continuous current:7 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,8 – 1,2
Protection type:RT III (wash-tight)
Size L x W x H:67 x 22 x 15,8 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 80 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5623

Safety relays OA 5601

Product description

  • To be used in circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology
  • Medical technology

Technical specifications

Contact equipping:4
Continuous current:3 x 16 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:57 x 20 x 39,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5601

Safety relays OA 5602

Product description

  • To be used in circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology
  • Medical technology

Technical specifications

Contact equipping:6
Continuous current:4 x 16 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:67 x 20 x 39,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5602

Safety relays OA 5603

Product description

  • To be used in circuits for safety applications
  • Escalators and walkways
  • Elevators for men and load
  • Railway technology
  • Medical technology

Technical specifications

Contact equipping:8
Continuous current:4 x 16 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:77,1 x 20 x 39,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 75 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5603

Safety relays, according DIN EN 50578 OA 5603/39__L1

Product description

  • To be used in electrical circuits for safety applications.
  • For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004 Typ C)

Technical specifications

Contact equipping:8
Continuous current:6 x 10 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,75 – 1,4
Protection type:RT II (flux-proof relay), optional RT III (wash-tight)
Size L x W x H:77,1 x 20 x 39,5 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 75 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:8 mm
Relay type:OA 5603/39__L1

Safety relays OA 5642

Product description

  • Switchgear for safety technology
  • Safety controls
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology

Technical specifications

Contact equipping:2
Continuous current:8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT III (wash-tight)
Size L x W x H:26,6 x 25 x 10,3 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5642

Safety relays OA 5643

Product description

  • Switchgear for safety technology
  • Safety controls
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology

Technical specifications

Contact equipping:3
Continuous current:2 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT III (wash-tight)
Size L x W x H:34,2 x 25 x 10,3 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5643

Safety relays OA 5644

Product description

  • Switchgear for safety technology
  • Safety controls
  • Escalators and walkways
  • Elevators for men and load
  • Press controls
  • Railway technology

Technical specifications

Contact equipping:4
Continuous current:3 x 8 A
Nominal voltage:DC 6 – 110 V
Voltage Range UN:0,7 – 1,6
Protection type:RT III (wash-tight)
Size L x W x H:41,7 x 25 x 10,3 mm
Test voltage (AC) contact set – coil:≥ 4 kV eff
Type of relay:Monostable
Temperature range (- / +):-40 – 85 °C
Type acc. to DIN EN 61810-3:A
Approvals:TÜV
Contact material:AgSnO2, AgNi
Clearance and creepage distances, contact set – coil ≥:5,5 mm
Relay type:OA 5644

For all your automation project needs:

Get in touch with us today!