Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,8 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 29 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 70 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5669 |
Datasheet Download
Safety relays OA 5669/3___

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 29 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5669/3___ |
Datasheet Download
Safety relays OA 5667

Product Overview
Product description
- Switchgear for safety applications
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,3 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 37 x 25 x 10,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5667 |
Datasheet Download
Safety relays OA 5667/____4

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,3 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 27 x 25 x 10,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5667/_____4 |
Datasheet Download
Safety relays OA 5670

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 35 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5670 |
Datasheet Download
Safety relays OA 5611

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 41,9 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611 |
Datasheet Download
Safety relays OA 5611/___S

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,8 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 41,9 x 14,5 x 30,35 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611/____S |
Datasheet Download
Safety relays, according DIN EN 50578 OA 5611/31__L1

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004)
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 41,9 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 70 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611/31__L1 |
Datasheet Download
Safety relays OA 5612

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 51,5 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5612 |
Datasheet Download
Safety relays, sensitiv OA 5612/____S

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,8 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 51,5 x 14,5 x 30,35 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5612/____S |
Datasheet Download
Safety relays OA 5621

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 46,5 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5621 |
Datasheet Download
Safety relays with double contacts OA 5621_D

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 46,5 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgNi + 5 µm Au |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5621_D |
Datasheet Download
Safety relays OA 5622

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 55 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5622 |
Datasheet Download
Safety relays with double contacts OA 5622_D

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 55 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgNi + 5 µm Au |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5622_D |
Datasheet Download
Safety relays OA 5623

Product Overview
Product description
- Railway and signalling applications
- Automation
- Medical devices
- Radio- and telecontrol applications
- Fuel applications
- Process applications
- Elevator applications
Technical specifications
Contact equipping: | 8 |
Continuous current: | 7 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,8 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 67 x 22 x 15,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5623 |
Datasheet Download
Safety relays OA 5601

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 57 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5601 |
Datasheet Download
Safety relays OA 5602

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 4 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 67 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5602 |
Datasheet Download
Safety relays OA 5603

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 8 |
Continuous current: | 4 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 77,1 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5603 |
Datasheet Download
Safety relays, according DIN EN 50578 OA 5603/39__L1

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004 Typ C)
Technical specifications
Contact equipping: | 8 |
Continuous current: | 6 x 10 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 77,1 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5603/39__L1 |
Datasheet Download
Safety relays OA 5642

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 2 |
Continuous current: | 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 26,6 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5642 |
Datasheet Download
Safety relays OA 5643

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 3 |
Continuous current: | 2 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 34,2 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5643 |
Datasheet Download
Safety relays OA 5644

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 41,7 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5644 |