Insulation fault location during operation in unearthed power supplies (IT systems) – VARIMETER EDS
A device for insulation fault location, also called IFLS (Insulation Fault Location System), enables insulation faults to be located within a very short time and is used in addition to an insulation monitor. In the event of a fault, it impresses a test current between the live conductors and earth. Components that are pre-damaged with regard to insulation can be located as quickly as possible and replaced before a failure occurs, i.e. there is no need to shut down the system.
Locating current injector RR 5886

Product Overview
Advantages
- Quick correction of insulation faults in complex power networks
- Universal auxiliary voltage range
Features
- Insulation troubleshooting in AC, DC and AC/DC networks (IT systems) in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
- Insulation coordination according to IEC 60664-1
- External control via insulation monitor possible
- Positive and negative test current to monitor DC networks and networks with simultaneous alternating current and direct current portions present
- RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the Modbus RTU field bus
- Modbus RTU interface for controlling the insulation fault location and readout of insulation fault currents
- Pushbutton for manual test current output
- Terminal connection for automatic test current output
- Status output of insulation fault detection via external switching output
- Width: 105 mm
Datasheet Download
Insulation fault locator RR 5887

Product Overview
Advantages
- Quick correction of insulation faults in complex power networks
- Universal auxiliary voltage range
- Easy operation
Features
- Insulation troubleshooting in AC, DC and AC/DC networks (IT systems) in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
- Insulation coordination according to IEC 60664-1
- Connection of max. 4 or 8 current transformers depending on the design
- RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the Modbus RTU field bus
- Status output of insulation fault detection via external switching output
- Memory characteristics adjustable via bridge X1-X2
- Collective signalling relay to output preliminary warning and alarm states
- Pushbutton for manual reset of alarm states as well as testing of current transformers and their calibration
- Terminal connection for the storage of alarm states
- Width: 105 mm