Motor brake relays

You are here:

MINISTOP – High-performance and flexible device solutions

The factors of safety and efficiency are an important argument for the motor braking devices of DOLD. The wear- and maintenance-free devices can be easily installed, even in existing systems. The configurable braking current allows an optimal adjustment to machines and systems.

Motor brake relay BA 9034N

Advantages

  • Higher safety level and more economic by short stopping cycle
  • Cost saving
  • Compact design
  • Easily appliance, no need for current measuring instrument

Features

  • According to IEC/EN 60947-4-2
  • For all single and 3-phase asynchronous motors
  • DC-brake with one way rectification up to max. 32 Aeff
  • Controlled by microcontroller
  • Easily fitted to existing installations
  • Wear free and maintenance free
  • Integrated braking contactor
  • DIN-rail mounting
  • Adjustable braking current (controlled current)
  • With automatic standstill detection
  • Variante /100
    – with braking time control
    – without detection of standstill
  • Width: 45 mm

Motor brake relay BA 9034N/802

Advantages

  • Higher safety level and more economic by short stopping cycle
  • Cost saving
  • Compact design
  • Easily appliance, no need for current measuring instrument
  • Regulated braking current

Features

  • According to IEC/EN 60947-4-2
  • For all single and 3-phase asynchronous motors
  • DC-brake with one way rectification up to max. 32 Aeff
  • Controlled by microcontroller
  • Easily fitted to existing installations
  • Wear free and maintenance free
  • Integrated braking contactor
  • DIN-rail mounting
  • Adjustable braking current (controlled current)
  • Width: 45 mm

Motor brake relay BI 9023

Features

  • According to IEC/EN 60947-4-2
  • DC brake with one way rectified brake voltage
  • Suitable foe all squirrel cage motors
  • Easy to fit also in existing circuits
  • Wear- and maintenance free
  • To mount on 35 mm DIN rail
  • Adjustable brake current to 80 A
  • Adjustable braking time 1 … 20 s
  • 90 mm width

Motor brake relay BI 9034

Advantages

  • Higher safety level and more economic by short stopping cycle
  • Cost saving
  • Compact design
  • Easy to set-up, no need for current measuring instrument

Features

  • According to IEC/EN 60947-4-2
  • For all single and 3-phase asynchronous motors
  • DC-brake with one way rectification up to max. 60 A
  • Controlled by microcontroller
  • Easily fitted to existing installations
  • Wear free and maintenance free
  • Integrated braking contactor
  • DIN-rail mounting
  • Adjustable braking current up to max. 60 A (controlled current)
  • With integrated star-delta starting function
  • With automatic standstill detection
  • Variant /800 with short circuit contactor control for reduced brake delay time
  • 90 mm Width

Motor brake relay BN 9034

Advantages

  • Higher safety and economic efficiency due to shorter run-out times
  • Easy to fit also into existing control circuits
  • Wear and maintenance free

Features

  • According to IEC/EN 60947-4-2
  • DC brake with one way rectifier up to 600 A
  • Can be used on all asynchronous motors
  • Integrated braking contactor for devices up to 60 A
  • Mounting on 35 mm DIN-rail for 25 A units
  • Adjustable braking current
  • With automatic standstill monitoring
  • As option with indicator relay for standstill monitoring
  • As option with star-delta start function
  • As option with thermistor motor protection
  • As option with wide voltage input
    BN 9034: 200 … 575 V, GB 9034: 200 … 690 V
  • Width max. 310 mm

Motor brake relay GB 9034

Advantages

  • Higher safety and economic efficiency due to shorter run-out times
  • Easy to fit also into existing control circuits
  • Wear and maintenance free

Features

  • According to IEC/EN 60947-4-2
  • DC brake with one way rectifier up to 600 A
  • Can be used on all asynchronous motors
  • Integrated braking contactor for devices up to 60 A
  • Mounting on 35 mm DIN-rail for 25 A units
  • Adjustable braking current
  • With automatic standstill monitoring
  • As option with indicator relay for standstill monitoring
  • As option with star-delta start function
  • As option with thermistor motor protection
  • As option with wide voltage input
    BN 9034: 200 … 575 V, GB 9034: 200 … 690 V
  • Width max. 310 mm

For all your automation project needs:

Get in touch with us today!