Relay with mechanically forcibly guided contacts
Safety technology is becoming increasingly important in mechanical and plant engineering. Safety modules or even safety controllers are used everywhere. Despite the increasing use of semiconductors, electromechanical relays are still an important component.
Next Product
Safety relays OA 5669

Product Overview
Product description
- Switchgear for safety technology
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,8 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 29 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 70 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5669 |
Datasheet Download
Safety relays OA 5669/3___

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 29 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5669/3___ |
Datasheet Download
Safety relays OA 5667

Product Overview
Product description
- Switchgear for safety applications
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,3 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 37 x 25 x 10,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5667 |
Datasheet Download
Safety relays OA 5667/____4

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 2 |
Continuous current: | 2 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,3 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 27 x 25 x 10,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A/B |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5667/_____4 |
Datasheet Download
Safety relays OA 5670

Product Overview
Product description
- Switchgear for safety technology
- Press controls
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 35 x 13 x 25,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5670 |
Datasheet Download
Safety relays OA 5611

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 41,9 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611 |
Datasheet Download
Safety relays OA 5611/___S

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,8 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 41,9 x 14,5 x 30,35 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611/____S |
Datasheet Download
Safety relays, according DIN EN 50578 OA 5611/31__L1

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004)
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 41,9 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 70 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5611/31__L1 |
Datasheet Download
Safety relays OA 5612

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 51,5 x 14,5 x 30,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5612 |
Datasheet Download
Safety relays, sensitiv OA 5612/____S

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 6 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,8 |
Protection type: | RT II (flux-proof relay) |
Size L x W x H: | 51,5 x 14,5 x 30,35 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5612/____S |
Datasheet Download
Safety relays OA 5621

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 46,5 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5621 |
Datasheet Download
Safety relays with double contacts OA 5621_D

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 46,5 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgNi + 5 µm Au |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5621_D |
Datasheet Download
Safety relays OA 5622

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 55 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5622 |
Datasheet Download
Safety relays with double contacts OA 5622_D

Product Overview
Product description
- To be used in electrical circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 5 x 5 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 55 x 22 x 15,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgNi + 5 µm Au |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5622_D |
Datasheet Download
Safety relays OA 5623

Product Overview
Product description
- Railway and signalling applications
- Automation
- Medical devices
- Radio- and telecontrol applications
- Fuel applications
- Process applications
- Elevator applications
Technical specifications
Contact equipping: | 8 |
Continuous current: | 7 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,8 – 1,2 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 67 x 22 x 15,8 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 80 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5623 |
Datasheet Download
Safety relays OA 5601

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 57 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5601 |
Datasheet Download
Safety relays OA 5602

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 6 |
Continuous current: | 4 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 67 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5602 |
Datasheet Download
Safety relays OA 5603

Product Overview
Product description
- To be used in circuits for safety applications
- Escalators and walkways
- Elevators for men and load
- Railway technology
- Medical technology
Technical specifications
Contact equipping: | 8 |
Continuous current: | 4 x 16 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 77,1 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5603 |
Datasheet Download
Safety relays, according DIN EN 50578 OA 5603/39__L1

Product Overview
Product description
- To be used in electrical circuits for safety applications.
- For railway signalling circuits according to DIN EN 50578 (UIC 736 R: 2004 Typ C)
Technical specifications
Contact equipping: | 8 |
Continuous current: | 6 x 10 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,75 – 1,4 |
Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
Size L x W x H: | 77,1 x 20 x 39,5 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 75 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 8 mm |
Relay type: | OA 5603/39__L1 |
Datasheet Download
Safety relays OA 5642

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 2 |
Continuous current: | 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 26,6 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5642 |
Datasheet Download
Safety relays OA 5643

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 3 |
Continuous current: | 2 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 34,2 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5643 |
Datasheet Download
Safety relays OA 5644

Product Overview
Product description
- Switchgear for safety technology
- Safety controls
- Escalators and walkways
- Elevators for men and load
- Press controls
- Railway technology
Technical specifications
Contact equipping: | 4 |
Continuous current: | 3 x 8 A |
Nominal voltage: | DC 6 – 110 V |
Voltage Range UN: | 0,7 – 1,6 |
Protection type: | RT III (wash-tight) |
Size L x W x H: | 41,7 x 25 x 10,3 mm |
Test voltage (AC) contact set – coil: | ≥ 4 kV eff |
Type of relay: | Monostable |
Temperature range (- / +): | -40 – 85 °C |
Type acc. to DIN EN 61810-3: | A |
Approvals: | TÜV |
Contact material: | AgSnO2, AgNi |
Clearance and creepage distances, contact set – coil ≥: | 5,5 mm |
Relay type: | OA 5644 |