SMX Base Modules

You are here:

SMX Base Modules include: SMX 100-1/2, SMX 100-2/2, SMX 100-4/2

i

SMX 100-1/2

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • 2 Auxiliary outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe / non-safe fieldbus interface

SMX 100-1/2/D

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication

SMX 100-1/2/DNM

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • Ethernet based fieldbus interface, safe / non-safe 
  • Memory Card for safety program

SMX 100-1/2/xNM

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet based fieldbus interface, safe / non-safe 
  • Memory Card for safety program

SMX 100-1/2/xxM

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Memory Card for safety program

SMX 100-1/2/DBM

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentral communication
  • CAN based fieldbus interface, safe / non-safe 
  • Memory Card for safety program

SMX 100-1/2/xBM

Free programmable and configurable modular safety controller

  • 14 Safe digital inputs
  • 2 Auxiliary outputs
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- pp-switching outputs
  • With integrated drive monitoring for up to 12 axes
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN based fieldbus interface, safe / non-safe 
  • Memory Card for safety program

Characteristic of the module

  • Extendable up to:
    • max. 126 safe digital inputs
    • max. 36 siafe digital outputs,
    • max. 120 safe digital I/O‘s,
    • max. 50 safe relay outputs,
    • max. 34 auxiliary outputs
    • and/or 12 safe axes
  • Freely programmable modular controller for up to 3000 IL instructions
  • Complete speed and position-based safety functions for drive monitoring in accordance with IEC 61800-5-2 are integrated in firmware
    • Spatial functions for safe speed and are monitoring are possible
  • Functionplan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Monitored relay outputs for safety relevant functions
  • Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Status monitoring by coded 7-segment-display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² Seriel USB-adapter or ethernet-based fi eldbus
  • Optional fieldbus interface (Expansion module for PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP/IP, PROFIsafe, FSoE)
  • Optional: Communication interface (/DNM, /DBM):
    •  Standard and safe fi eld bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Fieldbus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchnage with distrubted I/O systems
  • The mechanical construction of the SMX100-1/2 (/x*) is dependent on the respective forms of the base module

|

csm_SMX100-2_2_a9e79e7444

SMX 100-2/2

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

SMX 100-2/2/D

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication

SMX 100-2/2/DNM

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety controll suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 100-2/2/xNM

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety controll suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 100-2/2/xxM

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety controll suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Memory Card for safety program

SMX 100-2/2/DBM

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety controll suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

SMX 100-2/2/xBM

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 6 Auxiliary outputs
  • 20 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • 2/4 pn- or pp-switching outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety controll suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN-based fieldbus interface, safe / non-safe
  • Memory Card for safety program

Characteristic of the module

  • Extendable up to:
    • max. 126 safe digital inputs
    • max. 36 siafe digital outputs,
    • max. 120 safe digital I/O‘s,
    • max. 50 safe relay outputs,
    • max. 34 auxiliary outputs
    • and/or 12 safe axes
  • Free programmable modular controller for up to 3000 IL instructions
  • Complete speed and position-based safety functions for drive monitoring in accordance with IEC 61800-5-2 are integrated in firmware
    • Spatial functions for safe speed and are monitoring are possible
  • Functionplan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Monitored relay outputs for safety relevant functions
  • Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
  • Comprehensive diagnostics functions integrated
  • Status monitoring by coded 7-segment-display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² Seriel USB-adapter or ethernet-based fieldbus
  • Optional: Communication interface (/DNM, /DBM):
    • Standard and safe fieldbus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Fieldbus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchnage with distrubted I/O systems
  • The mechanical construction of the SMX100-2/2 (/x*) is dependent on the respective forms of the base module

|

SMX 100-4/2

Free programmable and configurable modular safety control

  • 14 Safe digital inputs
  • 10 Auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

SMX 100-4/2/D

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication

SMX 100-4/2/DNM

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory card for safety program

SMX 100-4/2/xNM

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Ethernet-based fieldbus interface, safe / non-safe
  • Memory card for safety program

SMX 100-4/2/xxM

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface
  • Memory card for safety program

SMX 100-4/2/DBM

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 Safe digital I/O‘s
  • 2 Safe relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Decentralized communication
  • CAN-based fieldbus interface, safe / non-safe
  • Memory card for safety program

SMX 100-4/2/xBM

Free programmable and configurable modular safety control

  • 14 safe digital inputs
  • 10 auxiliary outputs
  • 40 digital I/O’s
  • 2 relay outputs, 2 pulse outputs
  • Integrated drive monitoring for up to 12 axes
  • Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • CAN-based fieldbus interface, safe / non-safe
  • Memory card for safety program

Characteristic of the module

  • Extendable up to:
    • max. 126 safe digital inputs
    • max. 36 siafe digital outputs,
    • max. 120 safe digital I/O‘s,
    • max. 50 safe relay outputs,
    • max. 34 auxiliary outputs
    • and/or 12 safe axes
  • Free programmable modular controller for up to 3000 IL instructions
  • Complete speed and position-based safety functions for drive monitoring in accordance with
    IEC 61800-5-2 are integrated in firmware
    • Spatial functions for safe speed and are monitoring are possible
  • Functionplan oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact monitoring of connected switchgear (EMU)
  • Monitored relay outputs for safety relevant functions
  • Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
  • Comprehensive diagnostics functions integrated
  • Status monitoring by coded 7-segment-display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² Seriel USB-adapter or ethernet-based fieldbus
  • Optional: Communication interface (/DNM, /DBM):
    • Standard and safe fieldbus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Fieldbus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchnage with distrubted I/O systems
  • The mechanical construction of the SMX100-4/2 (/x*) is dependent on the respective forms of the base module