SMX Base Modules include: SMX 100-1/2, SMX 100-2/2, SMX 100-4/2
i

SMX 100-1/2
Free programmable and configurable modular safety controller
- 14 Safe digital inputs
- 2 Safe relay outputs, 2 pulse outputs
- 2/4 pn- pp-switching outputs
- 2 Auxiliary outputs
- With integrated drive monitoring for up to 12 axes
- Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe / non-safe fieldbus interface
Variants
SMX 100-1/2/D | Free programmable and configurable modular safety controller
|
SMX 100-1/2/DNM | Free programmable and configurable modular safety controller
|
SMX 100-1/2/xNM | Free programmable and configurable modular safety controller
|
SMX 100-1/2/xxM | Free programmable and configurable modular safety controller
|
SMX 100-1/2/DBM | Free programmable and configurable modular safety controller
|
SMX 100-1/2/xBM | Free programmable and configurable modular safety controller
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 126 safe digital inputs
- max. 36 siafe digital outputs,
- max. 120 safe digital I/O‘s,
- max. 50 safe relay outputs,
- max. 34 auxiliary outputs
- and/or 12 safe axes
- Freely programmable modular controller for up to 3000 IL instructions
- Complete speed and position-based safety functions for drive monitoring in accordance with IEC 61800-5-2 are integrated in firmware
- Spatial functions for safe speed and are monitoring are possible
- Functionplan oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Monitored relay outputs for safety relevant functions
- Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Status monitoring by coded 7-segment-display and status LEDs
- Multifunction button (quit, start, reset) can be operated from the front side
- Configurable via SafePLC² Seriel USB-adapter or ethernet-based fi eldbus
- Optional fieldbus interface (Expansion module for PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP/IP, PROFIsafe, FSoE)
- Optional: Communication interface (/DNM, /DBM):
- Standard and safe fi eld bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between multiple base devices
- Fieldbus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchnage with distrubted I/O systems
- The mechanical construction of the SMX100-1/2 (/x*) is dependent on the respective forms of the base module
|

SMX 100-2/2
Free programmable and configurable modular safety control
- 14 Safe digital inputs
- 6 Auxiliary outputs
- 20 Safe digital I/O‘s
- 2 Safe relay outputs, 2 pulse outputs
- 2/4 pn- or pp-switching outputs
- Integrated drive monitoring for up to 12 axes
- Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
SMX 100-2/2/D | Free programmable and configurable modular safety control
|
SMX 100-2/2/DNM | Free programmable and configurable modular safety control
|
SMX 100-2/2/xNM | Free programmable and configurable modular safety control
|
SMX 100-2/2/xxM | Free programmable and configurable modular safety control
|
SMX 100-2/2/DBM | Free programmable and configurable modular safety control
|
SMX 100-2/2/xBM | Free programmable and configurable modular safety control
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 126 safe digital inputs
- max. 36 siafe digital outputs,
- max. 120 safe digital I/O‘s,
- max. 50 safe relay outputs,
- max. 34 auxiliary outputs
- and/or 12 safe axes
- Free programmable modular controller for up to 3000 IL instructions
- Complete speed and position-based safety functions for drive monitoring in accordance with IEC 61800-5-2 are integrated in firmware
- Spatial functions for safe speed and are monitoring are possible
- Functionplan oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Monitored relay outputs for safety relevant functions
- Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
- Comprehensive diagnostics functions integrated
- Status monitoring by coded 7-segment-display and status LEDs
- Multifunction button (quit, start, reset) can be operated from the front side
- Configurable via SafePLC² Seriel USB-adapter or ethernet-based fieldbus
- Optional: Communication interface (/DNM, /DBM):
- Standard and safe fieldbus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between multiple base devices
- Fieldbus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchnage with distrubted I/O systems
- The mechanical construction of the SMX100-2/2 (/x*) is dependent on the respective forms of the base module
|

SMX 100-4/2
Free programmable and configurable modular safety control
- 14 Safe digital inputs
- 10 Auxiliary outputs
- 40 Safe digital I/O‘s
- 2 Safe relay outputs, 2 pulse outputs
- Integrated drive monitoring for up to 12 axes
- Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
SMX 100-4/2/D | Free programmable and configurable modular safety control
|
SMX 100-4/2/DNM | Free programmable and configurable modular safety control
|
SMX 100-4/2/xNM | Free programmable and configurable modular safety control
|
SMX 100-4/2/xxM | Free programmable and configurable modular safety control
|
SMX 100-4/2/DBM | Free programmable and configurable modular safety control
|
SMX 100-4/2/xBM | Free programmable and configurable modular safety control
|
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 126 safe digital inputs
- max. 36 siafe digital outputs,
- max. 120 safe digital I/O‘s,
- max. 50 safe relay outputs,
- max. 34 auxiliary outputs
- and/or 12 safe axes
- Free programmable modular controller for up to 3000 IL instructions
- Complete speed and position-based safety functions for drive monitoring in accordance with
IEC 61800-5-2 are integrated in firmware- Spatial functions for safe speed and are monitoring are possible
- Functionplan oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Monitored relay outputs for safety relevant functions
- Switchable safe semi-conductor outputs pn-, pp-switching for safety-relevant functions
- Comprehensive diagnostics functions integrated
- Status monitoring by coded 7-segment-display and status LEDs
- Multifunction button (quit, start, reset) can be operated from the front side
- Configurable via SafePLC² Seriel USB-adapter or ethernet-based fieldbus
- Optional: Communication interface (/DNM, /DBM):
- Standard and safe fieldbus protocols for communication with a higher level controller
(PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE) - Safe cross communication (SMMC) for data exchange between multiple base devices
- Fieldbus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchnage with distrubted I/O systems
- Standard and safe fieldbus protocols for communication with a higher level controller
- The mechanical construction of the SMX100-4/2 (/x*) is dependent on the respective forms of the base module