Two-hand controls on machinery and plants are used to protect operators against injuries by dangerous closing movements. The control unit is located outside the dangerous area to prevent the operator from getting into this area before a dangerous movement is actually stopped.
Advantages
Save cost by leaving out conventional contactor controls
Type-tested circuits complying with the requirements from the employers' liability insurance association
Compact prewired rail-mounted modules
Technology
Two-hand controls consist of an operating panel featuring two operating elements (control push buttons) which have to be arranged so that both hands must be used for operation. The DOLD evaluator module only releases once both control elements are operated simultaneously within 500 ms. The release command is present as long as both control elements remain operated. When one control element is unhanded a new control command can only occur if the other control element is also unhanded and both elements are operated again.
Applications
DOLD evalutor modules are used on all machines and plants where a dangerous closing movement may cause injuries of the operating personnel.