Safety Relay,ZanderSafety Relay,ZanderSafety Relay,ZanderSafety Relay,ZanderSafety Relay,Zander


Safety Relay from Zander

Safety,Relay,Zander

Emergency Stop Relay SRLC

Stop category: 0
Safety category: 3(4)
1 or 2 channel emergency stop circuit
Contacts: 2 force guided safety contacts AC 250V/6A
Operating Voltage: DC24V, AC230V, AC115V
Dimension: 22,5mm

Safety,Relay,Zander Safety,Relay,Zander

Safety,Relay,Zander

Emergency Stop Relay SR2C

Stop category: 0
Safety category: 4
2 channel emergency stop circuit
Contacts: 2 force guided safety contacts AC 250V/6A
Operating Voltage: DC24V, AC230V, AC115V
Dimension: 22,5mm
Cross-short circuit monitoring and/or shorting to ground monitoring

Safety,Relay,Zander

Emergency Stop Relay SR3C

Stop category: 0
Safety category: 4
2 channel emergency stop circuit
Contacts: 3 force guided safety contacts AC 250V/6A
Operating Voltage: DC24V
Dimension: 22,5mm
Cross-short circuit monitoring and/or shorting to ground monitoring

NEW: Now available with AC230/AC115V operation voltage

Safety,Relay,Zander

Safety Extension Contact Block SREC

Stop category: 0
Safety category: 3
Extension contact block to basic device of SR-Series
Contacts: 3 force guided safety contacts AC 250V/6A, 1 auxiliary contact
Operating Voltage: DC24V,  AC230V, AC115V
Dimension: 22,5mm
Shorting to ground monitoring

Safety,Relay,Zander

Time-delayed Safety Extension Contact Block SRTC

Stop category: 1
Safety category: 3
Extension contact block to basic device of SR-Series
Contacts: 3 force guided safety contacts AC 250V/6A, 1 auxiliary contact
Operating Voltage: DC24V, AC230V, AC115V
Dimension: 22,5mm
Shorting to ground monitoring
Adjustable time delay: 1-30s

Safety,Relay,Zander

Time-delayed Safety Emergency Stop Relay SR4C

Stop category: 1
up to Safety category: 4
3 non-time-delayed contacts and 1 time-delayed contact in just one compact housing
Contacts: 4 force guided safety contacts AC 250V/6A
Operating Voltage: DC24V
Dimension: 22,5mm
Shorting to ground monitoring
Adjustable time delay: 1-30s

Safety,Relay,Zander

Emergency Stop Relay SR1

Stop category: 0
Safety category: 3
1 or 2 channel emergency stop circuit
Contacts: 3 force guided safety contacts AC 400V/8A/2000VA, 2 auxiliary contacts
Operating Voltage: DC24V, AC230V, AC115V
Dimension: 100mm
Shorting to ground monitoring

Safety,Relay,Zander

Safety Two Hand Control Unit S2HC

Stop category: 0
Safety category: 4 / IIIC
2 channel stop circuit
Contacts: 2 force guided safety contacts AC 250V/6A
Operating Voltage: DC24V
Dimension: 22,5mm
Cross-short circuit monitoring and/or shorting to ground monitoring

   

Site Designed And Maintained By Panther Marketing And Design