| Brand | DOLD |
|---|---|
| Housing width | 17.5 mm |
| Output contacts | 1 C/O contact |
| Enclosure design | Distribution board |
| Phases | 1 |
| Order number | 0047645 |
DOLD IK 9173 – Undervoltage Relay, Single-Phase
- Brand
- DOLD
- Part number
- IK 9173
- Order number
- 0047645
Undervoltage Relay, Single-Phase
- Preventive maintenance
- For better productivity
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The IK 9173 and SK 9173 voltage relays in the VARIMETER series monitor AC voltage networks for undervoltage. The measurement is very simple and does not require a lot of wiring, as no separate auxiliary voltage is required. Early detection of impending failures and preventive maintenance prevent costly damage and, as a user, you benefit from the operational reliablility and high availability of your system.
Features
- According to IEC/EN 60255-1
- Monitoring of undervoltage
- Without auxiliary supply
- Optionally fixed or settable response value
- N.C. circuit operation
- Optionally with off-delay t1
- Optionally with on-delay t2
- LED indicator for state of output relay
- 1 changeover contact
- Devices available in 2 enclosure versions:IK 9173: Depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880SK 9173: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
- Width 17.5 mm
Technical specifications
| 1- / 3-phase | 1 |
|---|---|
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Nominal voltage max. | AC 230 V, DC 125 V |
| Operate delay | Yes |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 9173 |
Available variants
| Contact equipping | 1 changeover contact |
|---|---|
| Nominal voltage | AC 24 V · AC 42 V · AC 48 V · AC 60 V · AC 110 V · AC 127 V · AC 220 V · AC 230 V · AC 400 V · DC 24 V · DC 48 V · DC 60 V · DC 110 V · DC 125 V |
| Response value | 0,7 – 1,0 Un 4% · 0,7 Un 4% · 0,7/0,9 Un · 0,55 – 1,05 Un 4% · 0,75 Un 4% · 0,85 Un 4% |
| Time delay | 0,5 – 20 s · 2 – 200 s · 5 – 15 min · without |
| Variant | De-energized on trip. Without time delay. Settable response value · Energized on trip. Settable time delay t2. Settable response value · NC circuit operation. Settable time delay t1. Fixed response value · NC circuit operation. Settable time delay t1. Settable response value · NC circuit operation. Settable time delay t2. Fixed response value · NC circuit operation. Settable time delay t2. Settable response value · NC circuit operation. Without time delay. Fixed response value · NO circuit operation. Settable time delay t1. Settable response value · NO circuit operation. Without time delay. Settable response value |
Tell us the variant you need in your quote request.