You are here:

DOLD IL 9837 – Frequency Relay

Brand
DOLD
Part number
IL 9837
Order number
0056555

Frequency Relay

Category: SKU: DOLD-0056555 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

35 mm

Output contacts

1 C/O contact

Enclosure design

Distribution board

Phases

1

Order number

0056555

The frequency relay IL 9837, SL 9837 can be used to monitor the frequency of AC voltage systems, rotor frequency of slip ring motors, control/monitoring of motors on cranes, monitoring the output frequency of inverters (IL9837.11/500).

Features

  • According to IEC/EN 60255-1
  • Overfrequency or underfrequency monitoring of AC voltages
  • Adjustable response value fmin. or fmax 5 … 200 Hz or 15 … 600 Hz
  • Adjustable hysteresis
  • Large voltage range of the measuring input (nominal voltage AC 24 … 440 V)
  • De-energized on trip
  • LED indication for auxiliary voltage, measuring voltage and contact position
  • 1 changeover contact
  • As option for frequency inverters with a range of 1 … 300 Hz
  • 2 changeover contacts available on request
  • As option adjustable start-up delay available
  • Energized on trip function available on request
  • Devices available in 2 enclosure versions:IL 9837: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880SL 9837: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • 35 mm width

Technical specifications

1- / 3-phase 1
Auxiliary voltage required Yes
Enclosure design Distribution board
Measuring range max. 300 Hz
Operate delay Yes
Output contacts 1 C/O contact
Standard measuring range 5 – 200 Hz
Width 35 mm
Type IL 9837

Available variants

Auxiliary voltage AC 115 V · AC 230 V · AC 400 V · DC 12 V · DC 24 V
Contact equipping 1 changeover contact · 2 changeover contacts
Hysteresis 1 – 20 %
Measuring range 1 – 300 Hz · 2 – 500 Hz · 5 – 200 Hz
Start up delay 0,1 – 20 s · Without
Approvals and Markings CCC
Variant Frequency input for frequency inverters, selected with frequency mode. With measuring input for frequency inverters · Frequency input for frequency inverters, selected with frequency mode. With measuring input for frequency inverters. With adjustable start-up delay time · Monitoring from power systems of overfrequency and underfrequency. De-energized on trip

Tell us the variant you need in your quote request.