You are here:

DOLD MH 9143 – Mains Frequency Monitor

Brand
DOLD
Part number
MH 9143
Order number
0060945

Mains Frequency Monitor

  • Monitoring of 50 – and 60 Hz-current supply on over- and underfrequency
  • For precise frequency measuring with fast response time
  • High disturbance immunity
  • Separately adjustable trip points and separate outputs for overand underfrequency (1 or 2 c/o each)
Category: SKU: DOLD-0060945 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

45 mm

Output contacts

2 x 2 C/O contacts

Enclosure design

Switch cabinet

Phases

1

Order number

0060945

The MK 9143N and MH 9143 mains frequency monitors of the VARIMETER series are used to monitor the frequency of 50 and 60 Hz power supplies for over- and underfrequency. They are used for monitoring self-generating systems and local power supplies, as well as for monitoring generators, power units, etc.

Features

  • According to IEC / EN 60255-1
  • Monitoring of local generator sets and voltage supplies
  • MK 9143N / MH 9143:- Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz- Nominal frequency 50 or 60 Hz selectable- Fixed hysteresis optimised for trip point- Time delay for over and underfrequency each adjustable from 0 to 20 s- As option one common output for under and overfrequency- “Window”-mode (MK 9143N/400 / MH 9143/400)
  • MH 9143.38/008: With galvanic separated analogue output (current voltage) and 11 step LED chain for the actual frequency
  • MK 9143N/600 / MH 9143/600:- Variable alarm value in the range of 45 to 65 Hz- Hysteresis adjustable for under- and overfrequency separately adjustable 0 … 20 %- Common output for under and overfrequency “Window”-mode can be selected
  • Start up delay 0 … 30 s selectable
  • Manual or auto reset selectable
  • Output relay energized or de-energized on trip selectable for overfrequency
  • Output relay de-energized on trip for underfrequency
  • Universal frequency measuring input for AC 40 … 550 V
  • Several options for auxiliary supply
  • As option without aux. supply for voltage range AC 18 … 70 V or 70 … 275 V
  • LED indicators for auxiliary supply, input frequency, over and under frequency alarm
  • 2 possible contact arrangementsMK 9143N and MK 9143N/600: 2 x 1 C/O contacts, width 22,5 mmMH 9143 and MH 9143/600: 2 x 2 C/O contacts, width 45 mm

Technical specifications

1- / 3-phase 1
Auxiliary voltage required Yes
Enclosure design Switch cabinet
Measuring range max. 50/60 Hz
Operate delay Yes
Output contacts 2 x 2 C/O contacts
Standard measuring range 50/60 Hz
Width 45 mm
Type MH 9143

Available variants

Alarm delay 0 – 20 s · without
Auxiliary voltage AC/DC 110 – 230 V · AC 115 V · AC 230 V · AC 400 V · DC 24 V
Contact equipping 2 x 1 changeover contact · 2 x 2 changeover contacts
Response value + / – [0.1 – 5] Hz · 45 – 65 Hz
Start up delay 0 – 30 s
Variant Adjustable tripping values via 10-step switch. Adjustable time delay. Start up delay activatable via terminals · Variable tripping values. Adjustable hysteresis. Start up delay activatable via terminals

Tell us the variant you need in your quote request.

Downloads