Current Relay

  • Preventive maintenance
  • For better productivity
  • Quicker fault locating
  • Precise and reliable
Category: SKU: DOLD-0063176 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

22.5 mm

Output contacts

2 C/O contacts

Enclosure design

Switch cabinet

Phases

1

Order number

0063176

The current relay MK 9053N of the VARIMETER series monitors single phase DC or AC voltage systems (with 1 Measuring range for AC and DC). The adjustment is made via potentiometers on the front of the device. Early recognition and preventive maintenance avoid interruptions of electrical plants and provides a higher operational and plant safety.

Features

  • According to IEC/EN 60255-1, IEC/EN 60947-1
  • To: Monitor DC and AC
  • Measuring ranges from 2 mA up to 10 A
  • High overload possible
  • Input frequency up to 5 kHz
  • Galvanic separation between auxiliary circuit – measuring ciruit
  • With start-up delay
  • With time delay, up to max. 100 sec
  • As option with remote potentiometer
  • As option with manual reset
  • Option with fixed settings possible
  • LED indicators for operation and contact position
  • As option with pluggable terminal blocks for easy exchange of devices- With screw terminals- Or with cage clamp terminals
  • Width: 22.5 mm

Technical specifications

1- / 3-phase 1
Auxiliary voltage AC/DC
Enclosure design Switch cabinet
Measuring range AC, DC 0,002 – 10 A
Operate delay Yes
Output contacts 2 C/O contacts
Width 22,5 mm
Type MK 9053N

Available variants

Auxiliary voltage AC/DC 24 – 80 V · AC/DC 80 – 230 V
Contact equipping 2 changeover contacts
Measuring range AC 0,1 – 1 A · AC 0,5 – 5 A · AC 1 – 10 A · AC 2 – 20 mA · AC 16 2/3 Hz 20 – 200 mA · AC 20 – 200 Ma · AC 30 – 300 mA · AC 50 – 500 mA · AC 80 – 800 mA
Start up delay 0,1 – 20 s · 0,1 – 60 s · 1 – 100 s
Switching delay 0 – 20 s · 0 – 60 s · 0 – 100 s
Terminal type plug in cage clamp terminal · plug in screw terminal · screw terminal fixed
Approvals and Markings CCC
Variant Overcurrent relay, de-energized on trip · Overcurrent relay, de-energized on trip. With remote potentiometer · Overcurrent relay, energized on trip · Overcurrent relay, energized on trip. With manual reset, resetting by disconnecting the power supply · Overcurrent relay, energized on trip. With remote potentiometer · Undercurrent relay, de-energized on trip · Undercurrent relay, energized on trip · Undercurrent relay, energized on trip. With manual reset, resetting by disconnecting the power supply

Tell us the variant you need in your quote request.