You are here:

DOLD SK 9272 – Overcurrent Relay

Brand
DOLD
Part number
SK 9272
Order number
0050613

Overcurrent Relay

  • Adjustable switching delay
  • Closed circuit operation (output relay not activated in case of error)
  • Optionally open circuit operation (output relay activated in case of error)
  • Optionally manual reset, reset button on the front
Category: SKU: DOLD-0050613 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

10 mm

Output contacts

1 C/O contact

Enclosure design

Switch cabinet

Phases

1

Order number

0050613

The IK 9272 and SK 9272 overcurrent relays are suitable for monitoring currents in three-phase and alternating current networks. If the switchting point is exceeded, the relays change state after the time has elapsed. The relays can be used universally thanks to the adjustable switching point. Using the adjustable time delay, current peaks can be taken into account or faded out if required. The operational readiness and switching status of the output relay are signalled via an LED.

Features

  • According to IEC/EN 60255
  • Single phase
  • 1 changeover contact
  • Measuring ranges from 0.05 … 10 A
  • Fixed hysteresis approx. 4 %
  • Hysteresis function (auto reset)
  • LED indication for auxiliary voltage and contact position
  • Devices available in 2 enclosure versions:IK 9272: Depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880SK 9272: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • Width 17.5 mm

Technical specifications

1- / 3-phase 1
Auxiliary voltage AC
Enclosure design Switch cabinet
Measuring range AC 0,05 – 10 A
Operate delay Yes
Output contacts 1 C/O contact
Width 10 mm
Type SK 9272

Available variants

Auxiliary voltage AC 115 – 127 V · AC 220 – 240 V
Contact equipping 1 changeover contact
Measuring range 0,1 – 1 A · 0,5 – 5 A · 1 – 10 A · 50 – 500 mA
Switching delay 0,1 – 20 s
Variant 1-phasiges Stromrelais. Arbeitsstromprinzip. Nicht speichernd · 1-phasiges Stromrelais. Ruhestromprinzip. Nicht speichernd · Single phase current relay. De-energized on trip. With manual reset

Tell us the variant you need in your quote request.

Downloads