You are here:

DOLD SL 9171 – Undervoltage Relay

Brand
DOLD
Part number
SL 9171
Order number
0051677

Undervoltage Relay

Category: SKU: DOLD-0051677 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

35 mm

Output contacts

2 C/O contacts

Enclosure design

Switch cabinet

Phases

1, 3

Order number

0051677

Monitoring of voltage systems on undervoltage. Automatic switching to emergency supply or of emergency light in the case of phase loss according to DIN VDE 0100-710 or DIN VDE 0108.

Features

  • According to IEC/EN 60255-1
  • Monitoring of undervoltage in 3-phase system
  • Also for single phase
  • Without auxiliary supply
  • Optionally for 3p3w systems
  • LED indicator for state of output relay
  • Independent of phase sequence
  • 1 or 2 changeover contacts
  • Optionally fixed or settable response value
  • As option with phase sequence detection
  • Optionally with or without N
  • Optionally with off-delay t1
  • Opionally with on delay t2
  • Devices available in 2 enclosure versions:I-model: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880S-model: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • Width:IK 9171, SK 9171: 17.5 mmIL 9171, SL 9171: 35 mm

Technical specifications

1- / 3-phase 1, 3
Auxiliary voltage Without
Enclosure design Switch cabinet
Nominal voltage max. 3/N AC 500 / 290 V
Operate delay Yes
Output contacts 2 C/O contacts
Width 35 mm
Type SL 9171

Available variants

Contact equipping 2 changeover contacts
Nominal voltage 3/N AC 110 / 63 V · 3/N AC 220 / 127 V · 3/N AC 400 / 230 V · 3/N AC 480 / 277 V · 3AC 110 V · 3AC 400 V · 3AC 500 V
Response value 0,7 Un · 0,55 – 1,05 Un · 0,85 Un
Time delay 0,5 – 20 s · without
Variant With N. NC circuit operation. Settable time delay t1. Fixed response value · With N. NC circuit operation. Settable time delay t1. Settable response value · With N. NC circuit operation. Settable time delay t2. Fixed response value · With N. NC circuit operation. Settable time delay t2. Settable response value · With N. NC circuit operation. Without time delay. Fixed response value · With N. NC circuit operation. Without time delay. Settable response value · Without N. NC circuit operation. Settable time delay t1. Fixed response value · Without N. NC circuit operation. Settable time delay t1. Settable response value · Without N. NC circuit operation. Settable time delay t2. Fixed response value · Without N. NC circuit operation. Settable time delay t2. Settable response value · Without N. NC circuit operation. Without time delay. Fixed response value · Without N. NC circuit operation. Without time delay. Settable response value

Tell us the variant you need in your quote request.

Downloads