Guided Linear Unit with Incremental Encoder e. g. for press brakes

  • Free adjustable index impulse
  • Max. resolution of 0.001 mm* (at 4-edge triggering)
  • Power supply / signal level 5 V or 10-30 V
  • Differential signals / reference plus
Category: SKU: ELGO-GSI Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

ELGO

Order number

GSI2

*depending on order

Features

  • Free adjustable index impulse
  • Max. resolution of 0.001 mm* (at 4-edge triggering)
  • Power supply / signal level 5 V or 10-30 V
  • Differential signals / reference plus
  • Measuring length up to 1 meter
  • High-quality guiding system
  • Speed proportional square wave outputs
  • Robust, dirt and shock resistant
  • Cost-effective alternative to glass scales

Technical data

Mechanical data

Measuring principle incremental
Measuring length max. 1000 mm
Distance sensor / tape fixed by guide carriage
Housing dimensions (L x W x H) guide unit: 80 x 54 x 31 mm (without cable), guide rail: (150 + measuring length) x 55 x 20 mm
Housing material sensor head: zinc die cast, guiding carriage: aluminium
Connection type open cable ends, connectors optionally
Sensor cable 1.5 m standard length, others on request, drag chain suitable
Weight approx. 620 g at 330 mm measuring length

Electrical data

Power supply voltage 10 … 30 VDC or 5 VDC
Residual ripple 10 … 30 VDC: <10%, 5 VDC: ± 25 mV
Consumption 10 … 30 VDC: max. 50 mA, 5 VDC: max. 100 mA (with unloaded outputs)
Repeat accuracy ± 1 increment (without consideration of mechanical influences)
System accuracy ± (25 + 20 x L) L= measuring length in meter (without consideration of mechanical influences)
Output signals channels A, A’, B, phases shifted by 90° (phase shift ± 20%)
Output level HTL or TTL (depends on order information)
Reference pulse position adjustable
Output current max. 20 mA per channel
Resolution (at 4 edge evaluation) depends on order information
Max. output frequency per channel depends on selected resolution
Max. operating speed depends on selected resolution, e.g. mx. m/ss at 0.1 mm resolution

Environmental conditions

Storage temperature -25 … +85 °C
Operating temperature -10 … +70 °C, -25 … +85 °C on request
Humidity 95%, non-condensing
Protection class sensor head: IP67, mechanical parts: IP54