You are here:

ELGO LIMAX 33CP – Shaft information system

Brand
ELGO
Part number
LIMAX 33CP
Order number
LIMAX33CP

Absolute position detection and safety monitoring in one housing incl. eSGC (electronic safety gear activator)

  • Measuring height up to 262m
  • Operation speed up to 10 m/s
  • CAN/CANopen Interface
  • Available with or without eSGC Activator
Category: SKU: ELGO-LIMAX-33CP Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

ELGO

Order number

LIMAX33CP

Absolute position detection and safety monitoring in one housing incl. eSGC (electronic safety gear activator)

Features

  • Measuring height up to 262m
  • Operation speed up to 10 m/s
  • CAN/CANopen Interface
  • Available with or without eSGC Activator
  • Sensor cable with 3 or 5 m
  • User defined parameter setting

Technical data

Mechanical data

Measuring principle Absolute
Repeat accuracy ±1 increment
System accuracy in µm at 20°C ±(1000 + 100 x L) L = measuring length in meters
Distance sensor / magnetic tape the correct distance is guaranteed by guidance
Basic pole pitch 8 mm
Sensor housing material aluminium
Sensor housing dimensions L x W x H = 354 x 135 x 54 mm
Necessary magnetic tape AB20-80-10-1-R-D-15-BK80
Maximum measuring length 262 m
Connections 2 outlets with open wire ends for PIO and SCA cables(plug connectors on request)M12 4 pole male for eSGC; according to ICE61067-2-101
Sensor cable (PIO, SCA) standard length: 3.0 m (others on request)
Weight approx. 1400 g without cable; cable: approx. 60 g per meter

Electrical data

Supply voltage 18[1] … 30[2] VDC (stabilized). A SELV/PELV power supply must be used
Residual ripple < 100 mV
DZO rating + 24 VDC −20 %, max.200 mA (PNP)
Reverse polarity protection integrated
Power input max. 600 mA at 24 VDC
Interfaces CAN: CANopen DS406 or DS417
Digital input voltage 18 … 30 VDC for high level; open for low level
Relay contact ratingOC, SR1, SR2 · 0…230VAC (max. 250VAC), max. 2A· 24VDC (max. 30VDC), max. 1A· 48VDC (max. 53VDC), max. 600mA· 110VDC (max. 120VDC), max. 250mAeach with a resistive/inductive load with L/R < 40 ms
Rating for external supplyof SGC-actuator 24 VDC, min. 18 V; max. 30 V;constraints for connected trip coil to be observed

Environmental conditions

Storage temperature −25 … +85° C
Operation temperature −20 … +65° C
Humidity max. 95 %, non-condensing
Protection class IP54 (according to EN60529), higher on request
Interference emission / immunity EN 12015 / EN 12016
Vibration / shock resistance EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29
Others –
Maximum operating time 20 years
Safety relay contact reaction time < 55 ms
Solid state contact (eSGC) reaction time < 45 ms