| Brand | ELOBAU |
|---|---|
| Order number | 424D.1…, 424D.7… |
ELOBAU Angle sensor 424D
- Brand
- ELOBAU
- Part number
- 424D
- Order number
- 424D.1...+1 variants, see Ordering information
Current or voltage output signal
- Long lifetime and extremely reliable from contactless measurement with Hall principle
- Angle measuring range between 20° and 360°
- IP67 protection class for harsh environmental conditions
- Temperature range -40 °C to +85 °C
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
General information The angle measuring range lies between 20° and 359°. The measuring principle is contactless, based on a magnetic field rotating above the 2D Hall sensor. The system is short-circuit proof. There is no mechanical limit stop. Housing material: PBT.
The 360° angle sensor 424D is used for the detection of rotary movements from 20° to 360°. Angle sensor 424D is based on the contactless Hall measurement principle, which is extremely reliable and ensures a long service life.
Angle sensors are used, for example, in foot pedals for controlling mobile machinery or for position determination in cranes. Additionally, the 424D is ideal for use in excavators, robots or wind turbines thanks to its robust design.
Features
- Long lifetime and extremely reliable from contactless measurement with Hall principle
- Angle measuring range between 20° and 360°
- IP67 protection class for harsh environmental conditions
- Temperature range -40 °C to +85 °C
- Resolution 12 bit
Technical specifications
| Polarity reversal protection | yes |
|---|---|
| Output signal min. | 0.5 V DC |
| Output signal max. | 4.5 V DC |
| Output signal min. | 4 mA |
| Output signal max. | 20 mA |
| Output signal – centre position/zero position | 2.5 V DC |
| Output signal – centre position/zero position | 12 mA |
| Resolution | 0.09 ° |
| Operating voltage min. | 10 V DC |
| Operating voltage max. | 30 V DC |
| Current consumption | 30 mA |
| Load resistance min. | 100000 Ohm |
| Load resistance max. | 200 Ohm |
| Linearity error | < ±1 % / < ± 1 % |
| Signal sequence | CCW or CW/CCW |
| Signal update rate | 1600 Hz |
| Outputs (quantity, type) | 1 or 2 |
| Technology | Hall |
| Angle measuring range | 20°…360 ° |
| Outputs | 4…20mA / 0,5…4,5V |
| MTTF | 79.6 a / 115.9 a |
| Temperature coefficient | < ±1.2 % |
| EMC Agricultural and forestry machines (Norm) | EN ISO 14982pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 |
| EMC Earth-moving and building construction machinery (Norm) | DIN EN ISO 13766-1pulse “load dump”: max. voltage 35V (absolute) |
| EMC Industrial trucks (Norm) | DIN EN 12895 |
| Max. shaft load, axial | 50 N |
| Max. shaft load, radial | 100 N |
| Mechanical stop | no |
| Actuating lever | Selectable |
| Protection class | IP67 DIN EN 60529 |
| Operating temperature min. | -40 °C |
| Max. operating temperature | 85 °C |
| Min. storage temperature | -40 °C |
| Max. storage temperature | 85 °C |
| Torque for fastening screws | 2.5 N m |
| Connector type | Deutsch DT04-6P |