With ATEX approval 2014/34/EU

  • Protection class IP68 (up to 10 bar) ideal for applications in process industries
  • Matching actuators 30420000V, 30420000VS, 30420000VH, 30420000SH
  • Variants in intrinsically safe version for 1G/1D (Zone 0 / 20)
  • Variants in non-intrinsically safe version for 2G/2D (Zone 1 / 21)
Category: SKU: ELOBAU-SAFETY-SENSOR-671 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

ELOBAU

Order number

671V62I40, 671271M40, 671V62M40, 671271IU012, 671271I40, 671271K40, 671271MU0, 671271NU0, 671271N40, 671V62MU0, 671V62NU0, 671V62N40

Features

  • Protection class IP68 (up to 10 bar) ideal for applications in process industries
  • Matching actuators 30420000V, 30420000VS, 30420000VH, 30420000SH
  • Variants in intrinsically safe version for 1G/1D (Zone 0 / 20)
  • Variants in non-intrinsically safe version for 2G/2D (Zone 1 / 21)

Technical specifications

Guideline 2014/34/EU
Type examination certificate BVS 03 ATEX E 126 X
Actuators (standard) 304 200 00V; 304 200 00VH (hygienic version)
Notified body QM CE 0123
Actuators (amplified) 304 200 00VS; 304 200 00SH (hygienic version)
Version gas EX II 1G Ex ia IIC T6/T5 Ga / EX II 2G Ex mb IIC T6/T5 Gb / EX II 1/2G Ex ia IIC T6/T5 Ga/Gb
Contact form NO/NO / NO/NC
Version dust EX II 1D Ex ia IIIC IP68 T200105°C Da / EX II 2D Ex mb IIIC IP68 T105°C Db
Actuation front
Switching principle magnetic
Technology Reed
Ambient temperature range Ta, (Ii total: 0 … 60 mA) T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 … 150 mA) T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 … 60 mA) T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 … 150 mA) T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Use in zone (EX) 0, 1, 2 and 20, 21, 22 / 1 , 2 and 21, 22 / 0/1 , 1, 2 and 20, 21, 22
Switching frequency 5 Hz
Pollution degree 3
Effective internal capacitance (Ci) 2 nF
Effective internal inductance (Li) 10 µH
Series resistor 22 Ohm
Rated voltage Un (mb) 24 V AC/DC
Max. input voltage Ui (i) 24 V AC/DC
Structure acc. to EN ISO 13849-1 Two-channel
Coding acc. to EN ISO 14119 Low
B10d acc. to EN ISO 13849-1 4000000 / 20000000
Type acc. to EN ISO 14119 4
Mission time in years 20 a
Assured switching distance (Sao) with actuator (standard) 4 mm
Assured switching distance (Sao) with actuator (amplified) 7 mm
Minimum switching distance (So min) with actuator (standard) 0.5 mm
Minimum switching distance (So min) with actuator (amplified) 3 mm
Assured switch-off distance (Sar) with actuator (standard) 16 mm
Assured switch-off distance (Sar) with actuator (amplified) 20 mm / 23 mm
Housing design cylindrical
Minimum installation distance (between two sensors) 50 mm
Dimensions M30 x 53 mm
Detent present no
Earth terminal no / yes
Housing material Stainless steel
Cable material PVC
Housing colour silber
Nut material Stainless steel
Protection class IP68 10bar
Min. storage temperature -25 °C
Max. storage temperature 75 °C
Shock resistance (Norm) 30g / 11ms
Vibration resistance (Norm) 10 … 55 Hz
Mounting type Fastening nut
Thread M30
Cable type LIYCYW / Y – UL 2517
Cable colour grau / schwarz
Cable length 1 m

Where several values are listed, they differ between article numbers. Tell us the article number you need, or the values you need, in your quote request.

Ordering information

Available article numbers:

671V62I40, 671271M40, 671V62M40, 671271IU012, 671271I40, 671271K40, 671271MU0, 671271NU0, 671271N40, 671V62MU0, 671V62NU0, 671V62N40