Ultrasonic reflex sensor
- Mounting: Flush
- Switch type: Analog
- Signal Type: Analog voltage
- Connection: Connector
- Operating voltage: 15 – 30 V DC
Download datasheet (PDF)Ask an engineer
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The distance to an object will be calculated by the measured lead time from emission and receiving of an acoustic pulse. Because of high dependency from temperature the result is temperature compensated. According to the sensor type the output signal is analogue 0 … 10 V or 4 … 20 mA respectively digital PNP or NPN.
Product details
| Mounting | Flush |
|---|---|
| Switch type | Analog |
| Signal Type | Analog voltage |
| Connection | Connector |
| Dimension (in mm) | 36 x 32.5 x 101 |
Technical specification
| Operating voltage | 15 – 30 V DC |
|---|---|
| Max. load current | 40 mA |
| Operating temperature | -15 ° C to +70 ° C |
| Repeat accuracy | +/- 1mm|+/-0,2 % |
| Linearity | < 0,3 % |
| Switching state | LED |
| Analog output | yes 0-10V |
| Time delay | 100 ms |
| Sound beam | approx. 8 |
| Pulse rate of rise | teach in |
| Measuring range | 6-50 cm |
| Short-circuit proof | yes |
| Overload protection | yes |
| Reverse voltage protection | yes |
| Protection category | IP67 |
| EMC-level | DIN EN 60947-5-7:2004-06/DIN EN 60947-5-2:2008 |
| Housing material | Plastic |
| Termination | Connector M12 5-pin |
Downloads
- Data sheet KURT500-Q100KB-ANU-V2