You are here:

ZANDER AACHEN MINOS SLxD – safety relay with semiconductor output

Part number
MINOS SLxD
Order number
472800+7 variants, see Ordering information

Safety relay with semiconductor output

MINOS SLxD are safety emergency stop relays for monitoring emergency stop buttons, safety doors and light curtains, as well as contact reinforcement of safe outputs (e.g. safe PLC outputs) to machines and plants.

Category: SKU: ZANDER-MINOS-SLXD Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

ZANDER AACHEN

Approvals

CE, TÜV, UL

Cat. / PL (EN ISO 13849-1)

PL d; Cat. 3; SILCL 2

Supply voltage

UB: DC 24 V (+/- 10 %)

Order number

472800, 472801, 472804, 472805, 472802, 472803, 472806, 472807

MINOS SLxD are safety emergency stop relays for monitoring emergency stop buttons, safety doors and light curtains, as well as contact reinforcement of safe outputs (e.g. safe PLC outputs) to machines and plants.

The modules are also certified for furnaces in continuous operation according to EN 50156-1 as well as EN 746-2. For use in the process industry these modules are certified according to IEC 61511-1.

SLxD:Variant for max. requirements up to PL d / Cat.3 / SILCL 2 (according to EN ISO 13849-1; IEC 62061).

SL1D for dual-channel emergency stop circuit, safety door monitoring with short circuit monitoring

SL2D for light curtains, contact reinforcement, OSSD output or single-channel emergency stop

There are variants with manual start or auto-start.

These Module are available with screw terminals or tensile spring terminals.

Technical specifications

Safety function Safety emergency stop, safety doors, light curtains, contact reinforcement, OSSD, for furnaces in continuous operation, stop category 0
Certified according to EN ISO 13849-1; IEC 62061; IEC 61508; EN 50156-1; EN 746-2IEC 61511-1; EN 60204-1
PL; Cat.; SILCL (EN ISO 13849-1; EN 62061) PL d; Cat. 3; SILCL 2
Approvals CE, TUV, UL
Supply Voltage UB: DC 24 V (+/- 10 %)
Power consumption at UB = 24V 1.8 W (module enabled via S11. No load)
Number dual-channel inputs 1
Number start input 1 (auto-start or manual start each variant)
Max. switching capacity O1 ut UB. max. 2.5 A (see derating in the operating instructions)
Maximum switching capacity auxiliary output C1 max. 100 mA
Max. switch-on delay 10 ms
Off-delay (if requested via the safety circuit) < 13 ms
Ambient temperature -15 °C to 55 °C (see derating in the operating instructions)
Protection IP20
Mounting 35 mm DIN-rail
Dimensions 6.2 x 93.1 x 102.5 mm
Weight 50 g

Ordering information

Manual Start
MINOS SL1D, tensil spring terminal, manual start 472800
MINOS SL1D, screw terminal,manual start 472801
MINOS SL2D, tensil spring terminal, manual start 472804
MINOS SL2D, screw terminal, manual start 472805
Automatic Start
MINOS SL1D, tensil spring terminal, auto-start 472802
MINOS SL1D, screw terminal, auto-start 472803
MINOS SL2D, tensil spring terminal, auto-start 472806
MINOS SL2D, screw terminal, auto-start 472807

Quote the order number of the variant you need in your quote request.