You are here:

ZANDER AACHEN SR3D – 3NO/1NC safety modules

Part number
SR3D
Order number
472272+11 variants, see Ordering information

3NO/1NC safety modules

SR3D is a universally applicable safety relay with three safety relay outputs, specially designed for the use in furnaces in continuous operation according to EN 50156-1.

Category: SKU: ZANDER-SR3D Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

ZANDER AACHEN

Approvals

CE, GL, TÜV

Housing width

22.5 mm

Cat. / PL (EN ISO 13849-1)

PL e; Cat. 4; SILCL 3

Supply voltage

AC/DC 24 V / AC 115 V / AC 230 V

Order number

472272, 472271, 472270, 474272, 474271, 474270, 475272, 475271, 475270, 472592, 472595, 472596

SR3D is a universally applicable safety relay with three safety relay outputs, specially designed for the use in furnaces in continuous operation according to EN 50156-1. Additionally, it is certified by the Germanischer Lloyd under 32915-06HH and thus, approved for use at sea.For example, it is being successfully used in waste incineration plants on ships.

For contact protection, miniature circuit breakers (MCBs) rated at 3A (max.) with trip characteristics Type A, B, or C are permissible as an equivalent alternative to a fuse.

Technical specifications

Safety function Emergency stop monitoring, safety guard monitoring, light grids monitoring, safe coupling relay
Certified according to EN 60204-1; DIN EN ISO 13849-1; EN 62061; EN 50156-1; 13577-4; IEC 61508 parts 1-2 and 4-7; IEC 61511-1
Approvals CE, TUV, GL
Supply voltage AC/DC 24 V / AC 115 V / AC 230 V
Number of safe relay contacts 3
Max. switching capability of safe relay contacts 8 A / 250 VAC resistive load
Number of auxiliary relay contacts 1
Number of non time-delayed contacts 3
Number of time-delayed contacts –
Starting behavior Automatic start or manual, monitored start
PL; Cat.; SILCL (EN ISO 13849-1; EN 62061) PL e; Cat. 4; SILCL 3
Width 22.5 mm

Ordering information

Fixed screw terminals 472272 (24 V) / 472271 (115 V) / 472270 (230 V)
Incl. plug-in screw terminals 474272 (24 V) / 474271 (115 V) / 474270 (230 V)
Incl. plugable push-in twin spring connector 475272 (24 V) / 475271 (115 V) / 475270 (230 V)
EKLS4; set of plug-in screw terminals 472592
EKLT4; set of push-in twin spring connectors 472595
Spacer for a defined minimum distance between two safety relays (see derating) 472596

Quote the order number of the variant you need in your quote request.

Downloads