You are here:

DOLD RN 5884 – Residual Current monitor, Type B

Brand
DOLD
Part number
RN 5884
Order number
0068738

Residual Current monitor, Type B

  • Preventive fire and system protection
  • Increasing the availability of plants by early fault detection
  • Universal usage at AC/DC mains
  • Protection against manipulation by sealable transparent cover over setting switches
Category: SKU: DOLD-0068738 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

52.5 mm

Enclosure design

Distribution board

Order number

0068738

The AC/DC sensitive residual current monitor RN 5884 from the VARIMETER RCM series allows an early detection of insulation faults and detects differential currents with AC as well as DC components in grounded voltage systems (type B). The measurement takes place via an external current transformer.

The residual current monitors can be easily parameterised and set via the operating buttons. If the measured differential current exceeds the set response values, this is signalled via the output relays K1 or K2. In order to detect faults in the system at an early stage, the residual current is shown visually on a display.

All versions have 2 output relays. Units for a connectable current transformer give an alarm at output relay K1 and a pre-alarm at output relay K2. Units for 2 current transformers output an alarm message separately for each measuring channel (CT1) at relay K1 or (CT2) at relay K2.

Other features include wire break detection, test function and adjustable switching delays. Thus, the residual current monitor RN 5884 provides an information head start for targeted and cost-effective maintenance measure before the system comes to a standstill.

Features

  • According to IEC/EN 62020-1, VDE 0663
  • For AC and DC systems Type B
  • To detect earth faults in grounded voltage systems
  • Setting range from 30 mA … 5 A
  • Manual / auto reset, with alarm and pre-warning
  • With adjustable switching delay
  • Energized or de-energized on trip
  • Set parameters directly on the device
  • Display
  • LED indicator for RUN- / SET- Mode; BUS, Error
  • With test function
  • As option with analogue output
  • As option with Modbus RTU-interface
  • Broken wire detection
  • Width 52.5 mm

Technical specifications

Adjustable measuring ranges 0,03 – 5 A
Broken conductor detection Yes
Classification Type B (AC, DC even and pulsating)
Clear key Yes
Enclosure design Distribution board
Operate delay Yes
Relay contact / output Yes
Test key Yes
Type of voltage AC, DC
Width 52,5 mm
Type RN 5884

Available variants

Auxiliary voltage AC/DC 24 – 100 V · AC/DC 80 – 240 V
Contact equipping 1 changeover contact for alarm CT1, 1 changeover contact for alarm CT2 · 1 changeover contact for prewarning, 1 changeover contact for alarm
Measuring range 30 – 5000 mA
Time delay 0 – 10 s
Variant 1 measuring channel · 1 measuring channel. With Modbus RTU · 2 measuring channels · 2 measuring channels. With Modbus RTU

Tell us the variant you need in your quote request.