Safety control unit used to detect the uncontrolled movement of the lift cabin in accordance with EN 81-20.

Category: SKU: STEM-UCM-ELEVATOR-UNCONTROLLED-MOVEMENT-DETECTOR-NCUM50 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

STEM

Order number

NCUM50

Functional description

Safety control unit used to detect the uncontrolled movement of the lift cabin in accordance with EN 81-20.

Application fields

  • Elevator uncontrolled movement detection to be used with overspeed governor (OSG)
  • Leveling and re-leveling circuits

Main features

  • 24V AC/DC power supply
  • Inputs for safety chain
  • Inputs for floor position sensors
  • 1 Safety outputs for UCM
  • 1 Safety output for leveling and re-leveling
  • 2 Auxiliary outputs for UCM and leveling
  • Manual start for UCM circuit; manual or automatic start for leveling
  • Delayed activation of the UCM output dependeng of the landing/car door opening
  • Certified according to EN 81-20 and EN 81-50 as safety circuit for UCM detection
  • UCM test circuit inputs and outputs