| Brand | DOLD |
|---|---|
| Housing width | 45 mm |
| Output contacts | 2 C/O contacts |
| Enclosure design | Switch cabinet |
| Phases | 1 |
| Order number | 0051065 |
DOLD BA 9054 – Voltage relay
- Brand
- DOLD
- Part number
- BA 9054
- Order number
- 0051065
Voltage relay
- Protection against defect by overvoltage
- Preventive maintenance
- For better productivity
- Quicker fault locating
- Precise and reliable
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The voltage relay BA 9054 of the VARIMETER series monitors single phase DC or AC voltage systems (with 1 Measuring range for AC and DC). The adjustment is made via potentiometers on the front of the device. Early recognition and preventive maintenance avoid interruptions of electrical plants and provides a higher operational and plant safety.
Features
- According to IEC/EN 60255-1, IEC/EN 60947-1
- To: monitor DC and AC
- With measuring ranges from 15 mV to 1000 V
- High overload possible
- Input frequency up to 5 kHz
- Galvanic separation between Auxiliary Circuit – measuring ciruit
- Auxiliary supply AC and AC/DC
- Optionally with start-up delay
- With time delay, up to max. 100 sec
- Optionally with safe separation to IEC/EN 61140 (on request)
- As option with manual reset
- LED indicators for operation and contact position
- Width: 45 mm
Technical specifications
| 1- / 3-phase | 1 |
|---|---|
| Auxiliary voltage | AC, AC/DC, DC |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 1000 V, DC 900 V |
| Operate delay | Yes |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9054 |
Available variants
| Auxiliary voltage | AC/DC 24 – 80 V · AC/DC 80 – 230 V · AC 24 V · AC 42 V · AC 48 V · AC 110 V · AC 115 V · AC 127 V · AC 230 V · AC 240 V · AC 400 V · DC 12 V |
|---|---|
| Contact equipping | 1 changeover contact · 2 changeover contacts |
| Measuring range | AC 0,5 – 5 V · AC 1 – 10 V · AC 5 – 50 V · AC 10 – 150 Hz 25 – 250 V · AC 10 Hz 50 – 500 V · AC 15 – 150 mV · AC 16 2/3 Hz 5 – 50 V · AC 16 2/3 Hz 25 – 250 V · AC 16 2/3 Hz 50 – 500 V · AC 25 – 250 V · AC 50 – 500 V · AC 50 – 500 mV · AC 70 – 700 V · AC 100 – 1000 V · DC 1 – 10 V |
| Start up delay | 1 – 20 s · 1 – 30 s · 1 – 60 s · 1 – 100 s · Without |
| Switching delay | 0 – 2 s · 0 – 20 s · 0 – 30 s · 0 – 60 s · 0 – 100 s · 0 – 300 s · 20 s |
| Approvals and Markings | UKCA · UKCA, CCC |
| Variant | Overvoltage relay. De-energized on trip. Time delay at setting value · Overvoltage relay. De-energized on trip. Time delay at setting value. Overloadable up to AC 1000 V · Overvoltage relay. De-energized on trip. Time delay at setting value. With manual reset, resetting by disconnecting the power supply · Overvoltage relay. Energized on trip. Time delay at setting value · Overvoltage relay. Energized on trip. Time delay at setting value. Overloadable up to AC 1000 V · Overvoltage relay. Energized on trip. Time delay at setting value. With manual reset, resetting by disconnecting the power supply · Undervoltage relay. De-energized on trip. Time delay at hysteresis value · Undervoltage relay. De-energized on trip. Time delay at hysteresis value. Overloadable up to AC 1000 V · Undervoltage relay. De-energized on trip. Time delay at hysteresis value. With manual reset, resetting by disconnecting the power supply · Undervoltage relay. Energized on trip. Time delay at hysteresis value · Undervoltage relay. Energized on trip. Time delay at hysteresis value. Overloadable up to AC 1000 V |
Tell us the variant you need in your quote request.