You are here:

DOLD MK 9054N – Voltage relay

Brand
DOLD
Part number
MK 9054N
Order number
0063227

Voltage relay

  • Protection against defect by overvoltage
  • Preventive maintenance
  • For better productivity
  • Quicker fault locating
  • Precise and reliable
Category: SKU: DOLD-0063227 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

22.5 mm

Output contacts

2 C/O contacts

Enclosure design

Switch cabinet

Phases

1

Order number

0063227

The voltage relay MK 9054N of the VARIMETER series monitors single phase DC or AC voltage systems (with 1 Measuring range for AC and DC). The adjustment is made via potentiometers on the front of the device. Early recognition and preventive maintenance avoid interruptions of electrical plants and provides a higher operational and plant safety.

Features

  • According to IEC/EN 60255-1, IEC/EN 60947-1
  • To: Monitor DC and AC
  • With measuring ranges from 15 mV to 500 V
  • High overload possible
  • Input frequency up to 5 kHz
  • Galvanic separation between auxiliary circuit – measuring ciruit
  • Optionally with start-up delay
  • With time delay, up to max. 100 sec
  • Optionally with remote potentiometer
  • As option with manual reset
  • Option with fixed settings possible
  • LED indicators for operation and contact position
  • As option with pluggable terminal blocks for easy exchange of devices- With screw terminals- Or with cage clamp terminals
  • Width 22.5 mm

Technical specifications

1- / 3-phase 1
Auxiliary voltage AC/DC
Enclosure design Switch cabinet
Nominal voltage max. AC 500 V, DC 450 V
Operate delay Yes
Output contacts 2 C/O contacts
Width 22,5 mm
Type MK 9054N

Available variants

Auxiliary voltage AC/DC 24 – 80 V · AC/DC 80 – 230 V · DC 12 V
Contact equipping 2 changeover contacts
Measuring range AC 0,5 – 5 V · AC 1 – 10 V · AC 5 – 50 V · AC 6 – 60 mV · AC 15 – 150 mV · AC 25 – 250 V · AC 50 – 500 V · AC 50 – 500 mV
Operate delay 0 s · 0,1 – 20 s
Switching delay 0 – 20 s · 0 – 100 s
Terminal type fixed terminal block with screw terminal · pluggable terminal block with cage clamp terminals · pluggable terminal block with screw terminals
Approvals and Markings CCC
Variant Overvoltage relay. Closed circuit operation · Overvoltage relay. Energized on trip · Overvoltage relay. Energized on trip. With remote potentiometer · Undervoltage relay. Closed circuit operation · Undervoltage relay. De-energized on trip. With manual reset. Resetting by disconnecting the power supply · Undervoltage relay. De-energized on trip. With remote potentiometer · Undervoltage relay. Energized on trip · Überspannungsrelais. Arbeitsstromprinzip. Funktion speichernd. Fehlerquittierung durch Unterbrechung der Hilfsspannung

Tell us the variant you need in your quote request.