DOLD IK 9065 – Underload monitor (Cos-phi monitor)

Brand
DOLD
Part number
IK 9065
Order number
0055534

Underload monitor (Cos-phi monitor)

Category: SKU: DOLD-0055534 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

17.5 mm

Output contacts

1 C/O contact

Enclosure design

Distribution board

Phases

1, 3

Order number

0055534

The underload monitor IK / SK / SL 9065 measures the phase shift between voltage and current. The phase angle changes with changing load. This measuring method is suitable to monitor asynchronous motors on underload and no load independent of motor size. The early detection of up-coming break downs and preventive maintenance avoid expensive damages. As user you profit from the reliability and availability of your plant.

Features

  • According to EN 60255-1
  • Detection of underload (cos ϕ)
  • Without auxiliary supply
  • Current up to 8 A Motors up to 5 A nominal current can be connected directly
  • Higher currents via current transformer
  • SL 9065CT with integrated current transformer for currents up to 100 A
  • Adjustable response value
  • Automatic reset (Alarm auto reset)
  • Adjustable operate delay up to 100 s
  • De-energized on trip
  • For single and 3-phase loads e.g. motors
  • Independent of phase sequence
  • 1 changeover contact
  • LED indicator voltage supply and alarm
  • DIN rail or screw mounting
  • Devices available in 2 enclosure versions:IK 9065: Depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880SK 9065, SL 9065CT: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
  • IK 9065, SK 9065 width 17.5 mm
  • SL 9065CT width 35 mmIK/SK 9065/100: as IK/SK 9065 but:
  • Programmable for- Automatic reset or manual reset (latched alarm)- Energized or de-energized on trip
  • With reset button
  • Remote reset

Technical specifications

1- / 3-phase 1, 3
Auxiliary voltage Without
Enclosure design Distribution board
Measuring range max. 8 A
Operate delay Yes
Output contacts 1 C/O contact
Width 17,5 mm
Type IK 9065

Available variants

Contact equipping 1 changeover contact
Current range 0,1 – 2 A · 0,4 – 8 A
Nominal voltage 3AC 230 V · 3AC 400 V
Operate delay 1 – 100 s
Variant Without auxiliary supply. Manual reset programmable. Selection de-energized or energized on trip · Without auxiliary supply. Without alarm reset. De-energized on trip

Tell us the variant you need in your quote request.