| Brand | DOLD |
|---|---|
| Housing width | 45 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | AC/DC, DC |
| Approvals | UL |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Order number | 0063472 |
DOLD UH 5947 – Speed and standstill monitor
- Brand
- DOLD
- Part number
- UH 5947
- Order number
- 0063472
Speed and standstill monitor
- Three in one- Safe speed monitoring in automatic and set up operation- Safe standstill monitoring- Safe integrated gate monitoring
- For safety applications up to PL e / Cat 4 and SIL 3
- Space and costsaving, no external safe gate monitoring required
- Simple and time saving setup without PC
- Comfortable, menu guided configuration via frontside display
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The speed monitor UH 5947 provides safe monitoring of motors and rotating equipment. It is used in machines and plants where machine movements or moving parts can be a danger to men and machine. Using the front side display the parameters can be easily and comfortably adapted to the individual application or changed when necessary.
Features
- According to- PL e and category 4 to EN ISO 13849-1- SIL 3 to EN 61508
- Can be used in safety applications as follows:- Up to maximum SIL 3 according to EN IEC 62061
- Suitable for STO, SOS, SLS, SSM, SSR, SDL acc. to EN 61800-5-2
- Device setting on menu-driven display or via RJ45 (FCC Western-Modular 8P8C) with connection cable (copy function)
- Change tracking
- Adjustable operation mode- Automatic mode: Monitoring of automatic rotational speed window and standstill speed.- Setup mode: Monitoring of setup rotational speed window. Standstill is permanently enabled.
- Single or 2-channel safety gate monitoring
- Integrated user friendly display for parameters and operation status- For set point and actual value of U/min or m/min- Set point display also as frequency value- With numerous diagnostic features
- Adjustable start up delay (0 … 999 s)
- Adjustable time delay for standstill detection (13/14, 23/24) (0 … 999 s)
- Adjustable monitoring time for feedback circuit RF1 (0,5 … 999 s)
- Monitoring of an release magnet
- Monitoring of feedback circuits
- Activation of the output path 43/44, 53/54 with on/off pushbutton with short circuit detection or automatic making function
- Adjustable PNP- or NPN-sensors
- Connection of different encodern possible (sin/cos, TTL, HTL)
- 2-channel function
- Forcibly guided contacts
- LED-indicators and 2 semiconductor monitoring output
- With pluggable terminal blocks for easy exchange of devices- With screw terminals- Or with cage clamp terminals
- Width 45 mm
Technical specifications
| 1- / 2-channel | 2 |
|---|---|
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | For initiators and encoders |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 x 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| Nominal voltage | AC/DC, DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | UH 5947 |
Available variants
| Contact equipping | 4 NO contacts |
|---|---|
| Nominal voltage | AC/DC 110 – 240 V · DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with cage clamp terminals 2-wire · pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | At sensor selection E1+E2: The semiconductor outputs give out the incoming signal of E1 with a ratio 1:2. Other sensor selection: The emiconductor outputs have no function. For NAMUR sensors · For NAMUR sensors. At sensor selection E1+E2: The semiconductor outputs give out the incoming signal of E1 with a ratio 1:2. Other sensor selection: The emiconductor outputs have no function · For NAMUR sensors. Function standard · For PNP- NPN sensors. At sensor selection E1+E2: The semiconductor outputs give out the incoming signal of E1 with a ratio 1:2. Other sensor selection: The emiconductor outputs have no function · For PNP- NPN sensors. Function standard · For PNP- NPN sensors. The transistor outputs 38 and 68 are continuously on when the unit is on operation and are switched off as soon as failure is detected |
Tell us the variant you need in your quote request.