| Brand | DOLD |
|---|---|
| Housing width | 35 mm |
| Enclosure design | Distribution board |
| Order number | 0055137 |
DOLD IL 5882 – Residual current monitor, Type A
- Brand
- DOLD
- Part number
- IL 5882
- Order number
- 0055137
Residual current monitor, Type A
- Preventive fire and system protection
- Increasing the availability of plants by early fault detection
- With external residual current transformer
- Protection against manipulation by sealable transparent cover over setting switches
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The residual current monitors IL/SL 5882 of the VARIMETER RCM series are suitable for detecting insulation faults in earthed systems as well as for monitoring and preventive maintenance of electrical systems. Insulation deterioration can be detected at an early stage and indicated to the operator of the installation without immediately causing an interruption of operation.
Features
- According to IEC/EN 62020
- For AC and pulsating DC currants Type A to IEC/TR 60755
- 9 tripping values from 10 mA to 10 A or from 10 mA … 30 A
- Frequency range 20 … 2000 Hz
- Selection of manual or automatic reset
- With prewarning
- With test and reset button
- Broken wire detection
- Short reaction time
- With adjustable delay tv
- De-energized on trip
- LED indication for auxiliary supply and state of contact
- 2 x 1 changeover contact
- Devices available in 3 enclosure versions:IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43880- Width 35 mm- For connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts- Width 35 mm- For connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014
Technical specifications
| Adjustable measuring ranges | 0,01 – 10 A, 0,01 – 30 A |
|---|---|
| Broken conductor detection | Yes |
| Classification | Type A (AC, DC pulsating) |
| Clear key | Yes |
| Enclosure design | Distribution board |
| Operate delay | Yes |
| Relay contact / output | Yes |
| Test key | Yes |
| Type of voltage | AC, DC pulsating |
| Width | 35 mm |
| Type | IL 5882 |
Available variants
| Auxiliary voltage | AC/DC 12 V · AC/DC 24 – 230 V |
|---|---|
| Contact equipping | 1 changeover contact for prewarning, 1 changeover contact for alarm · 2 changeover contact for warning, without prewarning |
| Measuring range | 10 A · 30 A |
| Time delay | 5 s |
| Approvals and Markings | UKCA, CCC |
Tell us the variant you need in your quote request.