You are here:

DOLD IL 8701 – Input-Output interface relay

Brand
DOLD
Part number
IL 8701
Order number
0040284

Input-Output interface relay

  • Optionally contacts with up to a maximum 4 changeover contacts
  • Optionally for 2-wire initiator activation
  • Optionally for switching low loads
  • Optionally for switching lamps with parallel compensation (e.g. HQ lamps)
  • Optionally for switching large inductive direct current loads
Category: SKU: DOLD-0040284 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

35 mm

Supply voltage type

AC, AC/DC, DC

Output contacts

3 C/O contacts

Enclosure design

Distribution board

Order number

0040284

  • For switching lamp loads
  • Input interface relay, e.g. for activation of PLC
  • Output interface relay, e.g. for PLC-controlled loads

Features

  • According to EN 60947-5-1
  • Pushbutton for manual actuation of the contact
  • Operating position display
  • High thermal current Ith
  • Width: 17.5 or 35 or 52.5 mm

Technical specifications

Enclosure design Distribution board
Initiator triggering Yes
Nominal voltage AC, AC/DC, DC
Output contacts max. 3 C/O contacts
Suppressor circuit on the coil input Yes
Thermal current Ith max. 16 A
Width 35 mm
Type IL 8701

Available variants

Contact equipping 1 NO contact, 1 NC contact · 2 NC contacts · 2 NO contacts · 3 changeover contacts · 4 NO contacts · 4 changeover contacts
Nominal voltage AC/DC 24 V · AC/DC 110 V · AC 24 V 50 Hz · AC 42 V 50 Hz · AC 60 V 50 Hz · AC 63,5 V 50 Hz · AC 67 V 60 Hz · AC 110 V 50 Hz · AC 115 V 50 Hz · AC 120 V 50 Hz · AC 120 V 60 Hz · AC 125 V 50 Hz · AC 230 V 50 Hz · AC 230 V 60 Hz · AC 240 V 50 Hz · AC 400 V 50 Hz · DC 12 V · DC 24 V · DC 48 V · DC 60 V · DC 110 V · DC 125 V · DC 220 V · DC 230 V · DC 240 V
Variant – · 6 mm contact opening, for switching large inductive direct current voltage loads · Can be activated with 2-wire initiators · For switching low loads · For switching low loads. With protection diode to protect against wrong polarity and recovery diodes to reduce switching spikes. Plus on A2+ · With protection diode to protect against wrong polarity and recovery diodes to reduce switching spikes. Plus on A1+ · With protection diode to protect against wrong polarity and recovery diodes to reduce switching spikes. Plus on A2+ · With recovery diodes to reduce switching spikes. Plus on A1+ · With recovery diodes to reduce switching spikes. Plus on A1+. 6 mm contact opening · With recovery diodes to reduce switching spikes. Plus on A2+. Contact gab 6 mm

Tell us the variant you need in your quote request.

Downloads