You are here:

DOLD IL 9277 – Over- and Undercurrent Relay

Brand
DOLD
Part number
IL 9277
Order number
0049305

Over- and Undercurrent Relay

  • Detects over- and undercurrent
  • With built in current transformer for 0.5 … 100 A
  • IL 9277, SL 9277 with 4 programmable ranges
  • Separate setting for over- and undercurrent
  • Settable time delay
Category: SKU: DOLD-0049305 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

35 mm

Output contacts

2 C/O contacts

Enclosure design

Distribution board

Phases

1

Order number

0049305

The overcurrent and undercurrent relays of the VARIMETER series are suitable for monitoring currents in three-phase and alternating current networks. If the current exceeds or falls below the switching point, the relays change state after the time has elapsed. The relays can be used universally thanks to the adjustable switching point. The adjustable time delay can be used to take current peaks into account or to suppress them if necessary. Operational readiness and over- or undercurrent are indicated by an LED.

Features

  • According to IEC/EN 60255-1
  • IP 9277, SP 9277, SP 9277CT: 3-phaseIL 9277, SL 9277, SL 9277CT: Single phase
  • Measuring ranges from AC 0.1 … 15 A
  • Settable 0.1 … 1 IN
  • Fixed hysteresis approx. 4 %
  • LED indicators for over-, under- and normal current
  • Optionally energized on trip (output relay activated in case of error)
  • Devices available in 2 enclosure versions:- I-model, e.g. IL _ _ _ _, depth 61 mm with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43880- S-model, e.g. SL _ _ _ _, depth 100 mm with terminals at the top for cabinets with mounting plate and cable duct
  • DIN rail or screw mounting
  • IL 9277, SL 9277, SL 9277CT: 35 mm width IP 9277, SP 9277, SP 9277CT: 70 mm width

Technical specifications

1- / 3-phase 1
Auxiliary voltage AC, AC/DC
Enclosure design Distribution board
Measuring range AC 0,1 – 15 A
Operate delay Yes
Output contacts 2 C/O contacts
Width 35 mm
Type IL 9277

Available variants

Auxiliary voltage AC/DC 24 V · AC 115 – 127 V · AC 220 – 240 V · AC 400 – 440 V
Contact equipping 2 changeover contacts
Measuring range 0,1 – 15 A
Switching delay 0,1 – 20 s
Approvals and Markings CCC
Variant Single phase current relay. De-energized on trip · Single phase current relay. Energized on trip

Tell us the variant you need in your quote request.

Downloads