You are here:

DOLD LH 5946 – Standstill monitor

Brand
DOLD
Part number
LH 5946
Order number
0059266

Standstill monitor

  • Without sensor and safe
  • Fast reaction time
  • Easy to retrofit
  • Combined with Interlock SAFEMASTER STS
Category: SKU: DOLD-0059266 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

45 mm

Cat. / PL (EN ISO 13849-1)

4/e

SIL (IEC/EN 62061)

3

Supply voltage type

AC, DC

Approvals

UL

Connection

Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals

Order number

0059266

The safe sensorless LH 5946 standstill monitor is suitable for detects the standstill of 3-phase and 1-phase electric motors independent of the direction of rotation. This means sensors such as encoders or proximity switches are not required. The standstill monitor measures the induced voltage of the coasting motor. If the induced voltage approaches 0, this means motor standstill for the device and the output relay is activated.

Features

  • According to- Up to PL e and Kategorie 4 according to EN ISO 13849-1- Up to SIL 3 according to EN 61508 and EN 61800-5-2
  • Can be used in safety applications as follows:- Up to maximum SIL 3 according to EN IEC 62061- Up to SIL 3 according to EN 61511
  • Safe standstill detection on 3- and single-phase motors
  • No external sensors necessary
  • Independent of direction
  • Broken wire detection
  • Forcibly guided safety contacts: 3 NO contacts, 1 NC contact for AC 250 V
  • 2 semiconductor monitoring outputs
  • 1 monitoring output (NO contact)
  • Adjustable voltage setting
  • Adjustable standstill time delay
  • LED indicators for standstill, event of line breakage and operation voltage
  • Suitable for operation with inverters
  • Width 45 mm

Technical specifications

1- / 2-channel 2
Approvals UL
Cat. / PL acc. to EN ISO 13849-1 4/e
Classification Sensorless
Connection Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals
Forcibly guided output contacts max. 1 NC contact, 3 NO contacts
Indicator contacts 1 NO contact, 2 Semiconductor monitoring outputs
Measuring motor voltage max. 690 V
Nominal voltage AC, DC
SIL CL acc. to IEC/EN 62061 3
SIL acc. to IEC/EN 62061 3
Thermal current Ith max. 5 A
Width 45 mm
Type LH 5946

Available variants

Auxiliary voltage AC 24 V · AC 115 V · AC 230 V · AC 400 V · DC 24 V
Contact equipping 3 NO contacts, 1 NC contact
Response value 0,2 – 4 V · 20 – 400 mV
Terminal type pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with screw terminals · screw terminals fixed
Time range 0,2 – 6 s
Approvals and Markings UL-listed C/US, TÜV, UKCA, CCC

Tell us the variant you need in your quote request.