| Brand | DOLD |
|---|---|
| Housing width | 22.5 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | DC |
| Approvals | UL |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Order number | 0065426 |
DOLD UG 6970 – Multifunctional safety module
- Brand
- DOLD
- Part number
- UG 6970
- Order number
- 0065426
Multifunctional safety module
- 2 independent, separately adjustable safety funcions:- E-Stop- Safety gate- Two-hand control- Safety mat / Safety edge- Exclusive or contacts- Light curtain
- Only one device, two safety functions at the same time
- Manual or auto start
- Protection against manipulation by sealable transparent cover
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The multifunctional safety module UG 6970 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 2 out of 6 safety functions on rotary switches – ready. This reduces divers types of safety modules in stock and simplifies your disposition.
Features
- According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
- Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: 2 NO contacts per safety function
- 1 semiconductor output per safety function
- LED indicator for operation, safety function 1, 2 and failure
- As option with pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals
- Width: 22.5 mm
Technical specifications
| 1- / 2-channel | 2 |
|---|---|
| Application | Emergency stop, Light barrier, Safety gate, Safety mat, Two-hand |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Cross fault detection | Yes |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safe output contacts, redundant NO contacts | 4 |
| Thermal current Ith max. | 8 A |
| Width | 22,5 mm |
| Type | UG 6970 |
Available variants
| Contact equipping | 2 NO contacts each safety function |
|---|---|
| Nominal voltage | DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with cage clamp terminals 2-wire · pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
| Variant | 2 independent, separately adjustable safety functions |
Tell us the variant you need in your quote request.