Mains frequency monitor, for Modbus
- Simple parameterization, monitoring and diagnosis
- Compact design
- Universal measuring input for AC voltages from AC 24 … 690 V
- Auxiliary voltage ranges AC/DC 24 … 240 V
- Early detection of irregularities
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The UG 9443 mains frequency monitor from the VARIMETER PRO series monitors the mains frequency 1-phase and 3-phase AC grids. The device is ideal for applications in which a stable mains frequency is crucial for the reliable operation of machines, systems or supply networks – for example in energy distribution, industrial plants or in renewable energy generation. The mains frequency relay continuously monitors the mains frequency and reacts reliably to deviations from the set target value. Overfrequency and underfrequency can be conveniently set so that the device can be flexibly adapted to the respective requirements. The mains frequency monitor is easy to parameterize, monitor and diagnose via a Modbus RTU interface. Early detection of impending failures and preventive maintenance Prevent costly damage and, as s user, you benefit from the operational reliability and high availability of your system.
Features
- Multifunctional measuring relay acc. to IEC/EN 60255-1
- With galvanic separated Modbus RTU interface
- Frequency monitoring
- Start up time delay, response delay, off-delay
- Adjustable hysteresis 0.2 … 50 % of the response value
- Error memory
- Units optionally without relayUG 9443: Without relayUG 9443.12: 2 changeover contacts
- Relay function energized / de- energized on trip parameterisable
- Width 22.5 mm
Technical specifications
| 1- / 3-phase | 1 |
|---|---|
| Auxiliary voltage required | Yes |
| Bus interface | Modbus RTU |
| Enclosure design | Switch cabinet |
| Measuring range max. | 65 Hz |
| Operate delay | Yes |
| Output contacts | 2 C/O contacts |
| Standard measuring range | 35 – 65 Hz |
| Width | 22,5 mm |
| Type | UG 9443 |
Available variants
| Auxiliary voltage | AC/DC 24 – 240 V |
|---|---|
| Contact equipping | 2 changeover contacts · Without relay |
| Response value | 35 – 65 Hz |
| Terminal type | plug in mixed terminals |