| Brand | DOLD |
|---|---|
| Housing width | 100 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | AC, DC |
| Output contacts | 1 NC contact, 6 NO contacts |
| Approvals | UL-Recognized |
| Connection | Pluggable screw terminals |
| Order number | 0040375 |
You are here:
DOLD BO 5988 – Emergency stop module
- Brand
- DOLD
- Part number
- BO 5988
- Order number
- 0040375
Emergency stop module
Download datasheet (PDF)Ask an engineer
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
- Protection of people and machines
- Emergency stop circuits on machines
- Monitoring of safety gates
Features
- According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
- 1-channel or 2-channel connection
- Line fault detection at On pushbutton
- Feedback circuit X1-X2 for monitoring external contactors
- Integrated short-circuit and overvoltage protection
- LED displays for channels 1 and 2 and supply
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
- DIN 46 228-1/-2/-3-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Optionally with release delayed NO contact to 10 min
- Optionally automatic On function after connection of operating voltageor activation via On pushbutton
- Optionally cross fault detection in emergency stop control circuit
- Optionally dual voltage version
- Width 100 mm
Technical specifications
| 1- / 2-channel | 1, 2 |
|---|---|
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Cross fault detection | Yes |
| Nominal voltage | AC, DC |
| Output contacts max. | 1 NC contact, 6 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 10 A |
| Width | 100 mm |
| Type | BO 5988 |
Available variants
| Contact equipping | 3 NO contacts, 1 NO contact delayed, 1 NC contact as signal contact · 6 NO contacts, 1 NC contact as signal contact |
|---|---|
| Nominal voltage | DC 24 V · DC 24 V + AC 24 V · DC 24 V + AC 42 V · DC 24 V + AC 48 V · DC 24 V + AC 110 V · DC 24 V + AC 120 V · DC 24 V + AC 127 V · DC 24 V + AC 230 V · DC 24 V + AC 240 V |
| Time range | 0,1 – 1 s · 0,3 – 3 s · 0,5 – 5 s · 1 – 10 s · 1 s · 3 s · 5 s · 10 s · without |
| Approvals and Markings | TÜV, UKCA · UL-rec. C/US, TÜV, UKCA |
| Variant | Auxiliary supply is not necessary during elapse of time: tv adjustable · Auxiliary supply is not nesseary during elapse of time: tv adjustable. Dual voltage model · Auxiliary supply is not nesseary during elapse of time: tv fixed · Auxiliary supply is not nesseary during elapse of time: tv fixed. Dual voltage model · Dual voltage model 0.5 s operate delay with automatic restart · Without time delay · Without time delay. Dual voltage model |
Tell us the variant you need in your quote request.