| Brand | DOLD |
|---|---|
| Housing width | 17.5 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | DC |
| Output contacts | 3 NO contacts |
| Approvals | UL |
| Connection | Front side cage clamp terminals |
| Order number | 0067556 |
You are here:
DOLD UF 6925 – Emergency stop module
- Brand
- DOLD
- Part number
- UF 6925
- Order number
- 0067556
Emergency stop module
- For safety applications up to PL e / Cat. 4 e.g. SIL 3
- Space saving
- Connection front side
- Manual or automatic start
- Can be used also for safety gate
Download datasheet (PDF)Ask an engineer
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e-stop buttons and safety gates.
Features
- Corresponds to- PL e and category 4 according to EN ISO 13849-1- SIL 3 according to EN 61508- maximum SIL 3 according to EN IEC 62061
- Can be used in applications:- According to EN 61511- According to EN 50156-1 for furnaces
- 2-channel operation
- Forcibly guided output contacts
- With or without cross fault monitoring in the E-stop loop, switch S1
- Manual restart or automatic restart, switch S2
- LED indicator for channel 1, 2 and Netz
- Width 17,5 mm
Technical specifications
| 1- / 2-channel | 2 |
|---|---|
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Front side cage clamp terminals |
| Cross fault detection | Yes |
| Nominal voltage | DC |
| Output contacts max. | 3 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Suited as safety gate monitor | Yes |
| Thermal current Ith max. | 8 A |
| Width | 17,5 mm |
| Type | UF 6925 |
Available variants
| Contact equipping | 3 NO contacts · 2 NO contacts, 1 NC contact · 2 NO contacts |
|---|---|
| Nominal voltage | DC 8 – 36 V · DC 24 V |
| Approvals and Markings | UL-listed C/US, TÜV |
| Variant | Switching capacity standard. Start-Mode adjustable. Cross fault detection adjustable · Switching capacity standard. Start-Mode auto-start. Without cross fault detection · Switching capacity standard. Start-Mode auto-start. With cross fault detection · Switching capacity standard. Start-Mode manual-start. Without cross fault detection · Switching capacity standard. Start-Mode manual-start. With cross fault detection · Switching capacity for small loads. Start-Mode adjustable. Cross fault detection adjustable |
Tell us the variant you need in your quote request.