| Brand | DOLD |
|---|---|
| Housing width | 22.5 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | AC, AC/DC, DC |
| Output contacts | 4 NO contacts |
| Approvals | UL-Recognized |
| Connection | Pluggable screw terminals |
| Order number | 0050718 |
You are here:
DOLD BG 5924 – Emergency stop module
- Brand
- DOLD
- Part number
- BG 5924
- Order number
- 0050718
Emergency stop module
- For safety application up to PL e / Cat. 4 e.g. SIL 3
- Manual or automatic start
Download datasheet (PDF)Ask an engineer
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The emergency stop modules BG 5924 and IP 5924 from the SAFEMASTER series can be used to protect people and machines by interrupting a safety circuit in a safe way.
Features
- According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- According to EN 50156-1 for furnaces
- Single channel or two-channel operation
- Output: max. 4 NO contacts
- AC 230 V model with galvanic separation
- LED indicator for channel 1 / 2 and state of operation
- Short circuit detection between terminal Y1 and common
- BG 5924 with:- Removable terminal strips- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- BG 5924: width 22.5 mmIP 5924: width 70 mm
Technical specifications
| 1- / 2-channel | 1, 2 |
|---|---|
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Nominal voltage | AC, AC/DC, DC |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | BG 5924 |
Available variants
| Contact equipping | 2 NO contacts · 3 NO contacts, 1 NC contact · 4 NO contacts |
|---|---|
| Nominal voltage | AC/DC 24 V · AC/DC 48 V · AC 110 V 50/60 Hz · AC 115 V 50/60 Hz · AC 230 V 50/60 Hz · DC 24 V |
| Approvals and Markings | TÜV, UKCA, CCC · UL-rec. C/US, TÜV, UKCA, CCC |
| Variant | – · Voltage range with expandable tolerance 0,85 … 1,15 UN · With fast auto-start |
Tell us the variant you need in your quote request.