DOLD BH 9097 – Motor Load Monitor

Brand
DOLD
Part number
BH 9097
Order number
0053943

Motor Load Monitor

  • Identification of- Underload P1 and Overload P2- Overload P1 (prewarning) and Overload P2 programmable
  • Adjustment of P1 and P2 on absolute scale
  • For motors up to 22 kW / 400 V; 37 kW / 600 V
  • Large current range because of automatic range selection
  • De-energized or energized on fault, programmable
Category: SKU: DOLD-0053943 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

45 mm

Output contacts

2 x 1 C/O contacts

Enclosure design

Switch cabinet

Phases

1, 3

Order number

0053943

The load monitor BH 9097 of the VARIMETER series reliably monitors the load of motors as well as the functionality of electrical consumers. If the load exceeds or falls below the limit values, which can be set by means of a rotary switch, the corresponding output relay is activated. To suppress short-term load fluctuations, a response delay tv can be set. LEDs indicate the switching status of the associated output relays. Early detection of impending failures and preventive maintenance prevent costly damage, and as a user you benefit from the operational safety and high availability of your system.

Features

  • According to IEC/EN 60255-1
  • Measurement: Effective power
  • 1 changeover contact for P1 and 1 changeover contact for P2
  • Adjustable start-up time delay ta
  • Adjustable switching delay tv
  • With automatic or manual reset, programmable
  • Test / Reset button for easy setup
  • Up to 40 A without external current transformer
  • Also for single-phase operation
  • LED indicators
  • Width 45 mm

Technical specifications

1- / 3-phase 1, 3
Auxiliary voltage AC, DC, Without
Enclosure design Switch cabinet
Measuring range max. 40 A (37 kW)
Operate delay Yes
Output contacts 2 x 1 C/O contacts
Width 45 mm
Type BH 9097

Available variants

Auxiliary voltage AC 230/110 V · DC 24 V · Without
Contact equipping 2 x 1 changeover contact
Nominal current max AC 2,4 A · AC 6 A · AC 8 A · AC 12 A · AC 24 A · AC 40 A · AC 240 mA · AC 800 mA
Nominal voltage 3AC 60 – 440 V · 3AC 100 – 760 V · 3AC 400 V · 3AC 500 V · AC 35 – 250 V · AC 230 V · AC 400 V
Approvals and Markings – · CCC
Variant 1-phase with auxiliary supply. Start up delay time 0 – 30 s · 1-phase without auxiliary supply. Start up delay time 0 – 30 s · 3-phase with auxiliary supply. Start up delay time 0 – 30 s · 3-phase without auxiliary supply. Start up delay time 0 – 30 s