| Brand | DOLD |
|---|---|
| Housing width | 22.5 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | DC |
| Order number | 0068410 |
DOLD UG 6946 – Standstill monitor
- Brand
- DOLD
- Part number
- UG 6946
- Order number
- 0068410
Standstill monitor
- Without sensor and safe
- Fast reaction time
- Easy to retrofit
- Combined with Interlock SAFEMASTER STS
- Protection against manipulation by sealable transparent cover over setting switches
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The safe sensorless UG 6946 standstill monitor is suitable for detects the standstill of 3-phase and 1-phase electric motors independent of the direction of rotation. This means sensors such as encoders or proximity switches are not required. The standstill monitor measures the induced voltage of the coasting motor. If the induced voltage approaches 0, this means motor standstill for the device and the output relay is activated. With a width of only 22.5 mm, the UG 6946 can be accommodated in the control panel even under tight space conditions allowing easy retrofitting. For the implementation of different operating modes, the standstill monitor also offers the possibility of bridging the standstill monitoring (muting).
Features
- According to- Up to PL e and Kategorie 4 according to EN ISO 13849-1- Up to SIL 3 according to EN 61508 and EN 61800-5-2
- Can be used in safety applications as follows:- Up to maximum SIL 3 according to EN IEC 62061- Up to SIL 3 according to EN 61511
- Safe standstill detection on 3- and single-phase motors
- No external sensors necessary
- Independent of direction
- Broken wire detection
- Forcibly guided safety contacts:- 2 NO contacts for AC 250 V- 1 NC contact for DC 24 V
- Adjustable voltage setting
- Adjustable standstill time delay
- LED indicators for standstill, event of line breakage and operation voltage
- Suitable for operation with inverters
- Removable terminal strips:- UG 6946 PS: plug in screw terminals- UG 6946 PC: plug in cage clamp terminals
- Variant /_ _1:- Possibility of bridging the speed monitoring (muting)
- Width: 22.5 mm
Technical specifications
| 1- / 2-channel | 2 |
|---|---|
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | UG 6946 |
Available variants
| Auxiliary voltage | DC 24 V |
|---|---|
| Contact equipping | 2 NO contacts, 1 NC contact (internal NC contacts switched in parallel) · 2 NO contacts, 1 NC contact (internal NC contacts switched in series) |
| Response value | 0,2 – 4 V · 20 – 400 mV |
| Terminal type | plug in screw terminal · plug in terminal blocks with cage clamp terminals |
| Time range | 0,2 – 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
| Variant | With muting · Without muting |
Tell us the variant you need in your quote request.